40
NO.
Control
Control
Contents
Remark
Function
Objects
13 Power COMP.
failure
Clock
back-up
function
14
COMP. COMP.
restart
prevent
15
Buzzer Buzzer
function
16
First COMP.
defrost
F-fan
R-fan
Heater
17
Forced COMP.
defrost
F-fan
R-fan
Heater
18
Adjust
R1-sensor
off point
2. The electric devices are off for 2 hours in delivery function.
3. The custom LED is on normally.
1. M-PCB reserves all functions for 3 hours after power failure.
2. Time running in power failure is as follow.
1) Clock
2) Preventing COMP. restarting
3) Pause time during defrosting
1. After COMP. is off, the COMP. is not on even though the F-
sensor is at on point for 6 min.
1. Alarm buzzes 3 sec. after initial power on.
2. Alarm buzzes whenever each switch in F-PCB is pressed.
3. If the door is opened for more than 1 min., chirpy sound alarm
buzzes.
4. If adjust temperature, the fuzzy button will be not operative
and the buzzer will be off.
1. When power is loaded for the first time, it enters into defrost
mode if D-sensor 3.5˚C. (Defrost mode starts from Pre-cool
step.)
1. Press the fuzzy button 5 times, when press temperature/time
control button. After that can enter the forced defrost mode.
2. Forced defrost mode.
1) The Pre-cool step is omitted.
2) Start from R-fan defrost.
3. After forced defrost, the normal defrost is enabled in 15 hours
of accumulated COMP. on time.
1. When the temperature in fridge room is low (Low temperature
even though R-fan and COMP. are operating properly),
following functions are operating for easy after service.
FUZZY
TEMP
TIME SET
QUICK
FREEZING
QUICK
REFRIGERATION
FUZZY
SURROUND
CLEAN
FRZ.
REF.
Q.F
3
2
1
E.F E.R
1
2
3
Q.R