27
NO.
Control Control
Contents Remark
Function Objects
11 Device COMP.
test F-fan
function R-fan
Heater
12 Demo F-fan
function R-fan
LED
13 Delivery COMP.
function F-fan
R-fan
LED
1. Pressing the SW01 on M-PCB enables device test function.
2. Pressing the SW01 proceeds the operation of device as
follows.
COMP.
➝
D-heater
➝
break
➝
F-fan
➝
R-fan
➝
return
3. Each device is on for 1 min. and returns to be off.
4. During device test function, all custom LED of F-PCB is
illuminated.
➧
Custom LED check function
1. If the CN10 of M-PCB is shorted, it changes to demo function.
2. F-PCB indicates the normal status and fuzzy status alternately
in 15 sec. intervals.
3. F-fan and R-fan operation is same as below
1. This function operates when fridge temperature and quick
fridge button are pressed, and plug the power code.
2. At this time, the custom LED is normal and all devices are off.
3. After 10 min., all devices operate normally.
Normal status
FRZ.
FRESH
CLEAN
E.F 1 2 3 F F
4 5 5 4 3 2 1 E. F
Q. Q.
REF.
Fuzzy status
FRZ.
FUZZY
FRESH
CLEAN
E.F 1 2 3 F F
4 5 5 4 3 2 1 E. F
Q. Q.
REF.
FUZZY
QUICK
FRIDGE.
HOUR
FRIDGE
TEMP.
QUICK
FREEZING
FREEZER
TEMP.
MIN
TIME
SET
FRZ.
FRESH
CLEAN
E.F 1 2 3 F F
4 5 5 4 3 2 1 E. F
Q. Q.
REF.
Normal status Demo status
OFF ON
Door open
F-fan and R-fan is off F-fan and R-fan is on
at the same time. at the same time
ON OFF
Door close
F-fan : ON after 2 sec. F-fan : OFF after 2 sec.
R-fan : ON after 1 sec. R-fan : OFF after 1 sec.