22
1-10. Compulsive Defrosting
Input
Control Object
Contents
Remark
1. FRZ.SET
(Freezer
Temperatur
e) Button
2. REF.SET
(Refrigerator
Temp.)
Button
1. Defrosting
Mode
After Service (Heater) Compulsive Defrosting
1. How to start ; Push REF.SET button 5 times while pushing FRZ.SET
button.
2. How to proceed
1) Let Heater ON for 30seconds compulsively.
2) Delete Pre-Cool function of normal defrosting.
Heater Defrosting --> Pause --> Fan Delay -->Normal
3. Heater turns OFF if D-Sensor
≥
10°C, 30 seconds after Heater ON.
1-11. Time Delay of Electrical Parts
Input
Control Object
Contents
Remark
1. Door Switch
2. COMP
ON/OFF
1. F-FAN
2. R-FAN
1. F-Fan is ON/OFF 1 minute after COMP is ON/OFF.
2. Fan Delay and Priority
R/F/C-Fan works sequentially at 0.5 second's interval in order to pre-
vent initial over-current to DC Fan.
OFF
OFF
COMP
F FAN
ON
ON
Terms to be ON
ON
OFF
OFF
OFF
R FAN
F FAN
C FAN
ON
ON
0.5 second
1.0 second
1.5 second