Operation & Function
1. Temperature control
1) Freezer temperature control
- Temperature controlled by moving the lever horizontally.
- No relation with M-PCB. It just controls the cold air hole. ( Low is fully open, Winter is almost close the hole. )
2) Refrigerator temperature control
- The dial will be changed by the TEMP button.
- Initial mode is Mid and whenever pressing TEMP button, the dial will change as follows.
Low - Mide - High - Quick - Low
[Freezer]
[Refrigerator]
Low Mide High Quick Low
- Inner real temperature controlled by sensor on/off point.
- Each sensor on/off point controls Compressor & Fan motor operation.
- Fan motor is on/off after 1minute from compressor is on/off. ( Fan motor delay time is 1 minute. )
3) Quick Mode ( max. time limit is 40 min. )
- When Quick mode selected, led is on.
- When refrigerator sensor is below -3.0
℃
, this mode is end. Then returns to previous setting.
4) Control point in each mode
Control
Low
Mid
High
Quick
On (
℃
)
5.0
2.5
0.0
-
Off (
℃
)
3.0
0.5
-2.0
-3.0 (for 40 minute)
3