Operation & Function
7. Time delay of electric parts.
1) Normal control state : Fan motor is on/off after 1 minute from compressor on/off.
2) Initial plug-in : Fan motor is on after 4 minutes from compressor on.
3) Door opening
→
closing : Fan motor is on after 20 seconds.
8. Pull Down ( it is a kind of test mode )
1) How to start : Push the TEMP button 30 times.
2) How to exit
- Push the TEMP button 30 times again. or
- After 21 hours automatically ends.
3) Display : All LED is on.
4) Compressor / freezer fan & compressor cooling fan are on for 21 hours.
9. A/s Defrosting ( forced defrosting )
1) How to start : Push TEMP button 5 times while door is open.
2) How to exit
- Push TEMP button 5 times while door is open again.
3) Display : No display.
4) The process is the same with the defrosting mode without pre-cool.
8