2
ELECTRICAL ADJUSTMENT
1. PLAYBACK PHASE
ADJUSTMENT PROCEDURE
1. Play back the test tape. (DP-2)
2. Set the oscilloscope to the CHOP mode. Connect CH1 to the SW PULSE (PIN 4 of P504)
3. Connect CH2 to the ENVE signal (PIN5 of P504)
4. Insert PATH JIG and press "REC" button on the remote control.
5. Check the position of the V-sync from the rising edge of the SW pulse.
(Standard : 6.5H
±
0.5H)
ITEM
MODE
ADJUSTMENT
POINT
CHECK POINT
TEST
EQUIPMENT
TEST
TAPE
INPUT
SIGNAL
6.5H
ADJUSTMENT
PLAY
[REC] BUTTON
PIN 4 & PIN 5
OF P504
OSCILLOSCOPE
DP-2
NO SIGNAL
ADJUSTMENT PARTS
MEASURING POINT
PCB : MAIN - TOP VIEW
TMI
BLOC
PRE-
AMP
P50
TO PATH JIG
OSCILLOSCOPE
CH1 CH2
PATH JIG