2. PB EQ ADJUSTMENT
• Connection Method
• Adjustment Procedure
1) Set the INPUT mode to LINE mode.
2) Playback the SECAM test tape (DS-1).
3) Set the VCR to PLAY mode.
4) Connect the Oscilloscope to TJ402 and trigger the scope with the composite sync at TJ313.
5) Adjust RL492 in order to correspond with MAGENTA EDGE section.
TJ402 TJ313
RL492
ICL01
CH-1
OSCILLOSCOPE
CH-2
TOP VIEW
VIDEO PCB
Adj. Location
Checking Point
Measuring Equipment
Mode
Test Tape
R492
TJ402
Signal Gen, Oscilloscope
PLAY
DS-1
Horizontal: 10µs/div
vertical : 100mv/div