Safety  instructions

  

To guarantee the unit work normally, please read the manual carefully before installation,

  and try to install strictly according to this manual.

 Do not let air enter the refrigeration system or discharge refrigerant when moving the 
 air conditioner.

After installing, the consumer must operate the air conditioner correctly according
to this manual,keep a suitable storage for maintenance and moving of the air 
conditioner in the future.

       

There must be an air-break switch.

 

Check the connecting cables and pipes carefully, make sure they are correct and firm

 before connecting the power of the air conditioner.

        Fuse of indoor unit:  T 3.15A 250V. 

For 

 models 

f

 T 15A 250V or T 20A 250V . 

7k~12k 

use of outdoor unit: 

For 

models 

f

 T 30A 250V . 

21K~30k 

use of outdoor unit: 

  Properly ground the air conditioner into the earth.

  Warning: Risk of electric shock can cause injury or death: Disconnect all remote
  electric power supplies before servicing .

A residual current device(RCD)with the rating of above 10mA shall be incorporated
in the fixed wiring according to the national rule

  The maximum length of the connecting pipe between the indoor unit and outdoor
  unit should be less than 5 meters. It will affect the efficiency of the air conditioner
  if the distance longer than that length.
  This appliance can be used by children aged from 8 years and above and persons
  with reduced physical, sensory or mental capabilities or lack of experience and 
  knowledge if they have been given supervision or instruction concerning use of the 
  appliance in a safe way and understand the hazards involved. Children shall not
  play with the appliance. Cleaning and user maintenance shall not be made by 
  children without supervision.

  If the supply cord is damaged, it must be replaced by the manufacturer, its service
  agent or similarly qualified persons in order to avoid a hazard.

The batteries in remote controller must be recycled or disposed of properly. 
Disposal of Scrap Batteries --- Please discard the batteries as sorted municipal 
waste at the accessible collection point.
If the appliance is fixed wiring, the appliance must be fitted with means for
disconnection from the supply mains having a contact separation in all poles that
provide full disconnection under overvoltage category III conditions, and these
means must be incorporated in the fixed wiring in accordance with the wiring rules.

  The appliance shall not be installed in the laundry.

The appliance shall be installed in accordance with national wiring regulations.
The air conditioner must be installed by professional or qualified persons.

For 

 models 

f

 T 20A 250V . 

14k~18K

use of outdoor unit: 

Summary of Contents for DSB-F0983ELH-V

Page 1: ...DSB F0983ELH V DSB F1283ELH V DSB F1883ELH V DSB F2483ELH V ...

Page 2: ...tion of parts 4 Maintenance 6 Protection 7 Troubleshooting 8 Select the installation locations 10 Indoor unit installation 11 Outdoor unit installation 15 Installation diagram 9 Air purging 15 Wiring diagram 14 Installation instructions 9 Contents 2 Preparation before use Remote controller operating instructions See remote controller instructions ...

Page 3: ...ciency of the air conditioner if the distance longer than that length This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with ...

Page 4: ...tive 2002 96 EC Waste Electrical and Electronic Equipment WEEE This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and col...

Page 5: ...est the power supply cord be broken An electric shock or fire is probably caused by a broken power supply cord Never insert a stick or similar obstacle to the unit Since the fan rotates at high speed this may cause an injury Do not repair the appliance by yourself If this is done incorrectly it may cause an electric shock etc Turn off the appliance by remote control firstly before cutting off powe...

Page 6: ... Louver Vertical Adjustment Louver Horizontal Adjustment Air Filter Remote Controller Connection Cord Pipes and Power Drain Hose Emergency Panel Display Panel Note Condensate water drains at COOLING or DRY operation Identification of parts 4 Indoor unit Outdoor unit Air Intake Front Panel ON O FF MOD E FA N SW ING SL EE P SU PE R SM AR T IFEE L DIMMER TIMER ON TIMER OF F CL OC K ON OF F ON OF F ...

Page 7: ... lights up when the compressor is on Display set temperature It shows FC after 200 hours of usage as reminder to clean the filter After filter cleaning press the filter reset button located on the indoor unit behind the front panel in order to reset the display optional Temperature indicator 1 2 3 4 5 9 VG VL series Signal Receptor Timer Comp Run Sleep Super indicator It lights up in super mode 2 ...

Page 8: ...Emergency button 10 10 The symbols may be different from these models but the functions are similar 5 Display introduction ON OFF To let the AC run or stop by pressing the button TLseries 2 3 4 9 1 ...

Page 9: ...he front panel is very dirty Never sprinkle water onto the indoor unit Reinstall and shut the front panel Reinstall and shut the front panel by pressing position b downward If the dirt is conspicuous wash it with a solution of detergent in lukewarm water After cleaning dry well in shade Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment Stop the ...

Page 10: ...e of some products is allowed beyond the range In specific situation please consult the merchant o Room temperature is below 21 C o Room temperature is below 18 C If all operation has stopped press ON OFFbutton again to restart Timer should be set again if it has been canceled Install the air conditioner at a place that can bear its weight in order to operate more quietly Install the outdoor unit ...

Page 11: ...om working protector device The following cases may not always be a malfunction please check it before asking for service If there is strong interference from excessive static electricity discharge or power supply voltage abnormality the appliance may operate abnormally Disconnect the power supply and connect back 2 3 seconds later Changing mode during operation 3 minutes will delay This odor may ...

Page 12: ...the wall should be over 500mm should be over 200 mm should be over 50mm Distance from floor over 2500mm should be should be over 250mm Installation instructions Installation diagram Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple presentation of the unit it may not match the external appearance of the unit y...

Page 13: ...iping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page Where the air filter can be easily removed Keep the unit and remote controller 1m or more apart from television radio etc keep as far as possible from fluorescent lamps Do not put anything near the air inlet to obstruct it from air absorpti...

Page 14: ... 3 Indoor Unit Piping Installation Install a sleeve through the wall hole to keep the wall tidy and clean Drill a hole in the wall The hole should tilt a little downward toward outside Decide the position of the hole for piping according to the location of mounting plate 2 Drill a Hole for Piping Keep the mounting plate horizontal with a horizontal ruler or dropping line Drill holes of 32mm in dep...

Page 15: ...slot B Press to hook the pipe fixer onto the base Base Base Base Piping fixer Piping fixer Hook here Insert here drain hose drain hose large pipe large pipe small pipe small pipe Small pipe Large pipe Thermal insulation tube Power cord Drain hose prepared by user b Pre tighten them with fingers at first then use the wrenches a Connect indoor unit pipes with two wrenches Pay special attention to th...

Page 16: ...pecified in the power source specification 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be sure to install an earth leakage circuit breaker in wet or moist areas The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected Chassis Cabinet Front panel ...

Page 17: ...e only and the actual terminal shall prevail Outdoor unit Indoor unit Terminal Terminal Blue Blue Black 1 L 1 L 2 N 2 N 4 SI 4 SI Black BN BU YE GN RY1 ACIN L CN10 ACIN N Brown Indoor unit control board Indoor unit control board Evaporator YE GN YE GN 3 3 Brown Power supply BN BU YE GN RY1 ACIN L CN10 ACIN N Power supply Powerconnectingcord Powerconnectingcord Blue Gray Blue Gray B lack B la ck B ...

Page 18: ...ll the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure demonstrates The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units release air and moisture from the refrigerant cycle using a vacuum pump as shown below 15 Installatio...

Page 19: ...d soap or an electronic leak detector 7 Turn 2 and 3 way valves stem to fully close the valves Disconnect the flexible vacuum pump hose 8 Replace and tighten all valve caps 5 With vacuum pump still running close the low pressure knob on vacuum pump manifold Then stop the vacuum pump 2 Unscrew and remove cap from service valve 3 Connect vacuum pump flexible hose to the service valve How to Purge Ai...

Reviews: