SPECIFICATIONS

MODEL

DSB-182L

DSB-182L-R

DSB-182LH

DSB-182LH-R

Function

Cooling

Cooling / Heating

Power Supply

AC 220-240V, 50Hz

Cooling Capacity (Heating Mode)

17,500 BTU

18,000 BTU/h

Operating Current (Heating Mode)

9.6A

9.2 A

9.65 A (10.0 A)

9.2 A (9.5 A)

Power Consumption (Heating Mode)

2,134 W

2,000 W

Indoor Unit Dimensions

W 1035 x H 322 x D 205 mm

Outdoor Unit Dimensions

W 800 x H 615 x D 320 mm

Net Weight

Indoor

11.7 kg

12.1 kg

Outdoor

52.5 Kg

62 Kg

54 Kg

63.5 Kg

Connection

Type

Flare

the piping

Gas

1/2" (12.7 mm)

Liquid

1/4" (6.35 mm)

Air Cleaning

Anti-bacteria Filter, Electrostatic Filter, Deodorizing Filter

Operating

Indoor side (Heating Mode)

min 21°C ~ max 32°C

min 21˚C~max 32˚C (min 15˚C~max 27˚C)

Condition

Outdoor side  (Heating Mode)

min 21˚C ~ max 52˚C

min 21˚C~max 43˚C (min -5˚C~max 24˚C)

Design and specification are subject to change without notice for product improvemont.

18,000 BTU/h

(18,000 BTU/h)

2,000 W

(2,100 W)

2,150 W 

(2,235 W)

17,500 BTU/h

(18,500 BTU/h)

Summary of Contents for DSB-182L

Page 1: ...unit s weight A frame may be necessary for added support When installing in a room make sure the tubes are well insulated to protect the walls and furniture from sweating of the tubes When installing in moist or uneven locations make sure to use a raised level concrete pad or concrete blocks to provide a level solid foundation for the out door unit this prevents water damage and vibration When ins...

Page 2: ...normas detalladas de instalación por favor consulte el contrato con su suministador eléctrico si tiene que aplicar restricciones para productos como lavadoras aire acondicionado u homos eléctricos 4 Para detalles sobre las alimentación eléctrica del aire acondicionado consulte la placa de datos del aparato INSTRUCCIONES DE INSTALACION DEL AIRE ACONDICIONADO Hinweis entsprechend EMV Direktive 89 33...

Page 3: ...teries 8 Setting the Unit for Remote Operation 8 Celsius to Fahrenheit Conversion Chart 9 To Set the Unit to Auto Mode 9 To Operate Only Fan 10 To Set Unit to Cool Mode 10 To Set Unit to Dehumidifier Mode 11 To Select Fan Direction 11 To Set Unit to Quick Mode 12 To Set the On Timer Mode 12 To Set the Off Timer Mode 13 To Set Unit to Sleep Mode 13 To Set Unit to Heat mode Only LH LH R 14 Emergency...

Page 4: ...Plug Air Cleaning Filters Removes dust and prohibits germs AIR OUT Air In Sensor Wire Only DSB 182LH LH R Fan Direction Up Down Fan Direction Left Right ON OF F EN TE R CA NC EL TIM ER RE SE T FA N DIR FA N SP EE D MO DE SL EE P ON OF F TE MP LCD Remote Controller INDOOR UNIT Connection Cover Remove cover to access the AC connection to the indoor unit Service Valves The indoor and outdoor units ar...

Page 5: ...he emergency button EMERGENCY to operate by hand Open the front panel on emergency operating Remocon switch is usually used with remote con troller Indoor Unit Display Switch Panel ON Red Lights on during the operation Air clean Green Lights on during the operation Timer Yellow Lights on during the time of reservation mode Quick Red Lights on during the time of Quick Mode TIMER QUICK AIR CLEAN ON ...

Page 6: ...ion for fan ON OFF Button Press to turn the unit on or off TEMPERATURE Buttons Press to raise or lower the desired temperature FAN SPEED Button Press to select the fan speed High Middle Low Natural COVER Slide down to access most of the remote buttons Slide down further to access the battery compartment AUTO REMOTE CONTROLLER MODE Indicators Auto Quick Cool Fan Dehumidifier Lights to indicate the ...

Page 7: ...F Button Press to turn the unit on or off TEMPERATURE Buttons Press to raise or lower the desired temperature FAN SPEED Button Press to select the fan speed High Middle Low Natural COVER Slide down to access most of the remote buttons Slide down further to access the battery compartment AUTO FAN DIR FAN DIR REMOTE CONTROLLER MODE Indicators Auto Quick Cool Fan Dehumidifier Heat Lights to indicate ...

Page 8: ...pos sible battery leakage 5 Do not try to recharge batteries not intended to be recharged they can overheat and rupture Follow battery manu facturer s directions HOW TO INSTALL BATTERIES To install the batteries follow the procedures below Plug into 220V 240V AC Outlet 1 Slide down the cover to access most of the remote buttons Slide down further to access the battery compartment 2 Insert two AAA ...

Page 9: ...n on the remote control to turn the unit on the On LED will light on the indoor unit and ON will light in the remote display 2 Make sure the indicator appears in the remote display Using the TEMP or buttons set the desired temperature The desired temperature can be changed up or down 1 degree from the actual room temperature For temperature setting 24 28 C AUTO 3 Then the unit will automatically o...

Page 10: ...he display 3 Using the TEMP or buttons set the desired tem perature The desired temperature can be changed up to 32 C and down to 18 C 4 To select the fan speed press the FAN SPEED button until the desired speed appears in the display see below FAN SPEEDS AUTO The fan will automatically select the fan speed The fan will operate on low speed The fan will operate on medium speed The fan will operate...

Page 11: ...ill flow up First Press and down Second Normal air direction Press 1 Press the ON OFF button on the remote control to turn the unit on the On LED will light on the indoor unit and ON will light in the remote display 2 Press the MODE button to select the desired mode 3 Press the FAN DIR button to select the fan direction See chart below for detailed information on each of the three settings FAN DIR...

Page 12: ...ENTER button to input the setting into memory the unit will beep the TIMER indicator will light on the unit and the TIMER indicator on the remote will light to indicate the unit is in the timer mode 1 Press the ON OFF button of timer on the remote control to set the on timer mode HOUR and ON on the remote display will be displayed and TIMER will be flicked When you increase to press ON OFF you wil...

Page 13: ...2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 8 5 9 9 5 10 11 12 AUTO 5 When the desired hour is reached the unit will turn off AUTO NOTE Press the ENTER button within 5 seconds of select ing the desired time If mote than 5 seconds elapse steps 3 and 4 must be repeated 1 Press the ON OFF button on the remote control to turn the unit on the On LED will light on the indoor unit and ON will light in the remote...

Page 14: ... the Heat indicator appears in the display In the heat mode the fan direction UP DOWN is further downward than that in the cool mode for the good circulation TO SET UNIT TO HEAT MODE ONLY DSB 182LH 182LH R To set the unit to heat the room to a desired temperature follow the procedures below FAN SPEEDS AUTO The fan will automatically select the fan speed The fan will operate on low speed The fan wi...

Page 15: ...dorizing and Electrostatic from the indoor unit 5 Insert cleaned or new black filters back into the unit 3 Examine the filters and determine if they need to be cleaned or replaced To clean filters use a vacuum and clean off dust Use water and mild soap also if necessary NOTE The filters should be changed every 6 months If in a climate with cold winters once a year is adequate 4 Insert cleaned or n...

Page 16: ...all Clean the air filters Cover the outdoor unit with the supplied cover this is very important to protect this unit BEFORE THE SEASON Make sure the air filters are clean Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions Make sure the unit is grounded Consult a serviceman for help PRECAUTIONS Do not use this unit for animal or plant storage In a lightni...

Page 17: ...o heat air at heating If the unit is turned off and then Wait 3 minutes for the unit to operate immediately back on the compressor will delay for 3 minutes The air filter s is dirty or clogged Clean or replace filter s A door or window is open Shut door or window There is an obstacle in front of Remove obstacle intake or indoor unit The temperature has been set Check and reset if necessary imprope...

Page 18: ...x H 615 x D 320 mm Net Weight Indoor 11 7 kg 12 1 kg Outdoor 52 5 Kg 62 Kg 54 Kg 63 5 Kg Connection Type Flare the piping Gas 1 2 12 7 mm Liquid 1 4 6 35 mm Air Cleaning Anti bacteria Filter Electrostatic Filter Deodorizing Filter Operating Indoor side Heating Mode min 21 C max 32 C min 21 C max 32 C min 15 C max 27 C Condition Outdoor side Heating Mode min 21 C max 52 C min 21 C max 43 C min 5 C ...

Page 19: ...MODEL DSB 182L DSB 182LH DSB 182L R DSB 182LH R OWNER S MANUAL S1 SPLIT AIRCONDITIONING SYSTEM ...

Reviews: