DSA-245L, 245P
72
PROCEDURES PHOTOS
1.Stop the operation of the air conditioner and disconnect the wire from in
door unit to out door unit.
2. Disassemble the case. (Fig 1~2)
1
Remove the Top Panel.
2
Remove the Front Cabinet.
3
Remove the Side Cabinet and Back Cabinet.
3. Removing the Propeller Fan. (Fig 3)
1
Loosen the screw fixed at the motor bracket.
2
Remove the Plain Washer.
3
Remove the Propeller Fan.
4. Removing the panel control. (Fig 4)
1
Disconnect the wire at the control panel.
2
Loosen the screw at the panel control.
3
Remove the parts on the panel control.
5. Removing the vaccum pump.
6. Remove the partition panel. (Fig 5)
1
Loosen four screws at the bracket motor.
2
Disconnect the wire at the control panel.
7. Removing the Over load Protector. (Fig 6)
1
Remove the cocondenser
2
Loosen three volts at the compressor.
3
Remove the compressor.
Fig 1
Fig 2
Fig 3
Fig 5
Fig 4
Fig 6
Summary of Contents for DSA-095L
Page 1: ...Manual de servicio Split Acondicionador de Aire Modelo ...
Page 26: ...25 4 WIRING DIAGRAM Indoor Unit DSA 095L DSA 125L DSA 185L 245L ...
Page 27: ...26 Indoor Unit DSA 125P DSA 185P DSA 245P ...
Page 28: ...27 Outdoor Unit DSA 095L DSA 125L 125P DSA 185L 185P DSA 245L 245P ...
Page 29: ...28 5 CONTROL BLOCK DIAGRAM DSA 095L DSA 125L 125P ...
Page 30: ... DSA 185L 185P 29 ...
Page 31: ... DSA 245L 245P 30 ...
Page 40: ...39 DSA 095L DSA 125L 125P 8 PCB DRIVING DESCRIPTION ...
Page 41: ...40 DSA 185L 185P ...
Page 42: ...41 DSA 245L 245P ...
Page 66: ...65 5 U9 KIA7042P RESET IC KIA70 42P OUTLINE INPUT GROUND OUTPUT VCC 1 3 2 OUT GND ...
Page 74: ...73 3 EXPLODED VIEW PARTS LIST Indoor Unit INDOOR UNIT EXPLODED VIEW DSA 095L ...
Page 76: ...75 26 1 INDOOR UNIT EXPLODED VIEW DSA 125L 125P ...
Page 80: ...79 28 1 28 27 INDOOR UNIT EXPLODED VIEW DSA 245L 245P ...
Page 82: ...81 4 EXPLODED VIEW PARTS LIST OUTDOOR UNIT OUTDOOR UNIT EXPLODED VIEW DSA 095L ...
Page 84: ...83 OUTDOOR UNIT EXPLODED VIEW DSA 125L 125P ...
Page 86: ...85 OUTDOOR UNIT EXPLODED VIEW DSA 185L 185P ...
Page 88: ...87 OUTDOOR UNIT EXPLODED VIEW DSA 245L 245P ...
Page 90: ...89 5 CONTROL BOX ASSEMBLY 3 8 7 4 5 1 9 q 6 2 0 DSA 095L ...
Page 92: ...91 9 DSA 125L 125P ...
Page 94: ...93 DSA 185L 185P ...
Page 97: ...95 DSA 245L 245P ...