Main PCB Trouble Diagnosis
10-3. Trouble Diagnosis and Repairing Method for Representative Symptoms
(1)When POWER SHUT DOWN occurs
<1> Definition of SHUT DOWN
- When LED Color is Green, can t hear POWER operating sound. (Red : STAND BY, Green :
Operating)
- When Turn OFF and turn ON AC SWITCH again, and turn Remote Control POWER ON ,
POWER RELAY do not operate normally, and POWER operating sound can not be detected.
<2> PCB Check Priority (Left to Right)
- POWER, X-SUS, Y-SUS, SCANL/H, DATA, DIGITAL, VIDEO, CONN-LEFT/RIGHT
<3> Trouble Repairing Procedure
- As shown in FIG<10-1>, first check which of LOW VOLTAGE part or HIGH VOLTAGE
part has a trouble.
- If LOW VOLTAGE part is broken is checked, as shown in FIG<10-2> diagnose the SET and
then replace the broken PCB.
- If HIGH VOLTAGE part is broken is checked, as shown in FIG<10-3>
diagnose the SET and then replace the broken PCB.
- <Note.1> When disconnecting/connecting connectors, you must turn OFF the AC power and
check the direction/position of them before working.
- <Note.2> If you turn the SET ON
with X-SUS PCB and Y-SUS PCB s POWER
CONNECTORS (P101A, P201A) disconnected, although you turn the SET OFF
again, Remaining Voltage still exists in the POWER PCB. Therefore assemble the
connectors several minutes after. Or, check the Remaining Voltage (Vsus, Vadd) by
multimeter. If Vsus is less 10V, connect connectors. Connecting connectors with the
Remaining Voltage (Vsus,Vadd) over 10V could generate sparks and be dangerous to
Operators or SET.
(2)When Screen Discharge (luminescence) is abnormal
<1>
Definition of Abnormal Screen Discharge (luminescence)
- In Entire or part of screen, irregular and unstable Discharge arises. (Refer to Trouble Symptom
Picture<8>)
- This symptoms are divided into No Discharge and Wrong Discharge
- No Discharge : Pixels which should discharge do not emit light. When WHITE PATTERN is
displayed, one of RED, GREEN, BLUE does not emit light, so CYAN(GREEN+BLUE),
MAGENTA(RED+BLUE) or YELLOW(RED+GREEN) shows on some part of the screen.
- Wrong Discharge : Pixels which should not discharge emit light. When single color like RED,
GREEN, BLUE pattern is displayed, CYAN(GREEN+BLUE), MAGENTA(RED+BLUE) or
YELLOW(RED+GREEN) shows on some part of the screen.
- If No Discharge or Wrong Discharge is severe, it can be easily detected when any moving
image is displayed. But if it is not severe, it can be detected only when certain particular
Summary of Contents for DP-42GM
Page 10: ...10...
Page 41: ...41 Adjusting Method FIG 6 1 X SUS PCB Adjusting Points...
Page 42: ...42 Adjusting Method FIG 6 2 Y SUS PCB Adjusting Points...
Page 56: ...56 Main PCB Trouble Diagnosis 2 DHS 3 DEN...
Page 57: ...57 Main PCB Trouble Diagnosis 4 DCLK 5 CLK50M...
Page 58: ...58 Main PCB Trouble Diagnosis 6 M_CLK 7 F_SUBF...
Page 59: ...59 Main PCB Trouble Diagnosis 8 CLK480 9 SLCT...
Page 85: ...84...
Page 86: ...86 13 FIGURE COLLECTION FIG 1 TOTAL...
Page 87: ...87 FIGURE COLLECTION FIG 2 Y SUS SCAN...
Page 88: ...88 FIGURE COLLECTION FIG 3 X SUS...
Page 89: ...89 FIGURE COLLECTION FIG 4 VIDEO JACK...
Page 90: ...90 FIGURE COLLECTION FIG 5 POWER...
Page 91: ...91 FIGURE COLLECTION FIG 6 INLET...
Page 92: ...92 FIGURE COLLECTION FIG 7 LEFT UP...
Page 93: ...93 FIGURE COLLECTION FIG 8 LEFT DOWN...
Page 94: ...94 FIGURE COLLECTION FIG 9 RIGHT UP...
Page 95: ...95 FIGURE COLLECTION FIG 10 RIGHT DOWN...
Page 96: ...96 FIGURE COLLECTION FIG 11 WITHOUT JACK...
Page 97: ...97 FIGURE COLLECTION FIG 12 DIGITAL...
Page 98: ...98 FIGURE COLLECTION FIG 13 AC SWITCH ASSEMBLY...
Page 99: ...99 FIGURE COLLECTION FIG 14 SCAN ASSEMBLY 1...
Page 100: ...100 FIGURE COLLECTION FIG 15 SCAN ASSEMBLY 2...
Page 101: ...101 FIGURE COLLECTION FIG 16 X SUS_ASSEMBLY...
Page 102: ...102 FIGURE COLLECTION FIG 17 FRONT MASK_ASSEMBLY...
Page 103: ...103 FIGURE COLLECTION FIG 18 FRONT MASK_INSIDE...
Page 104: ...104 FIGURE COLLECTION FIG 19 BACK COVER...
Page 105: ...105 FIGURE COLLECTION FIG 20 POWER ADJUSTING POINTS...
Page 106: ...106 FIGURE COLLECTION FIG 21 POWER HIGH VOLTAGE SWITCH...
Page 107: ...107 FIGURE COLLECTION FIG 22 HOW TO ADJUST VOLTAGE...
Page 108: ...108 FIGURE COLLECTION FIG 23 Y SUS SCAN PCB DIODE TEST...
Page 109: ...109 FIGURE COLLECTION FIG 24 SCANH PCB DIODE TEST...
Page 110: ...110 FIGURE COLLECTION FIG 25 SCANL PCB DIODE TEST...
Page 111: ...111 FIGURE COLLECTION FIG 26 5 STEP GRAY SCALE PATTERN...
Page 112: ...112 14 Trouble Sumpton Picture Trouble Symptom Picture 1...
Page 113: ...113 Trouble Sumpton Picture Trouble Symptom Picture 2...
Page 114: ...114 Trouble Sumpton Picture Trouble Symptom Picture 3...
Page 115: ...115 Trouble Sumpton Picture Trouble Symptom Picture 4...
Page 116: ...116 Trouble Sumpton Picture Trouble Symptom Picture 5...
Page 117: ...117 Trouble Sumpton Picture Trouble Symptom Picture 6...
Page 118: ...118 Trouble Sumpton Picture Trouble Symptom Picture 7...
Page 119: ...119 Trouble Sumpton Picture Trouble Symptom Picture 8...
Page 120: ...120 Trouble Sumpton Picture Trouble Symptom Picture 9...
Page 121: ...121 Trouble Sumpton Picture Trouble Symptom Picture 10...
Page 122: ...122 Trouble Sumpton Picture Trouble Symptom Picture 11...
Page 123: ...123 Trouble Sumpton Picture Trouble Symptom Picture 12...
Page 124: ......