65
DESCRIPTION
Micom 35 Terminal put out Buzzer Driving Pulse,
its output is driving Buzzer through Buffer.
Ocillatory Frequency of buzzer is selected by
internal Micom.
This unit is setting at 4KHz.
VCC
12V
MICOM
35
R6
1K
BZ1
Buzzer Driving(10)
DESCRIPTION
Indoor Fan Motor RPM is set by each registance.
(R27, R28, R29, R30, R31)
30
29
28
27
26
1K
1K
1K
1K
1K
R26
R25
R24
R23
R28
R29
R30
R31
R22
MICOM
CA1
F5 104Z
RA1
R27
heat/low
heat/high
cool/low
cool/high
monitoring
6A 103J
I/D FAN RPM SETTING