INDEX

1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION 

..................................................................... 2

2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS
OF PUMP’S MOTORS 

................................................................................................................................ 3

3. POSSIBLE WORKING DEFECTS 

........................................................................................................... 3

4. UNIT STARTING AND WORKING 

........................................................................................................... 4

6. TECHNICAL DATA 

.................................................................................................................................. 4

WARRANTY 

................................................................................................................................................. 5

1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION

2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS OF PUMP’S 
MOTORS

3. POSSIBLE WORKING DEFECTS

4. UNIT STARTING AND WORKING

WARNING: 

Never take the electronic board out of the control box.

The wiring diagram inside the terminal block will show you how to make correct connection.

Wrong connection will destroy the whole electronic circuit. Cable used for connection must be a 
three-wired one with compulsory grounding end. It shall have the outer diameter at 6 mm min and 9 
mm max. One of the leading end of the cable must be lower than the position of the fixing screws 
while the cable being connected to the power as shown in the fig.

The four screws on the panel board and the two nuts for fixing cable must be well fastened to avoid 
water entering into the control box and damaging the electronic circuit.

6. TECHNICAL DATA

Power: 1.1 kW
Current: 10 A
Maximum working pressure: 10 bar
Max working temperature: 60ºC
Connection: G1

male

Protection rating: IP54

1