background image

1. INSTRUCTIONS FOR CORRECT UNIT INSTALLATION

2. WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT KINDS OF PUMP’S 
MOTORS

3. POSSIBLE WORKING DEFECTS

4. UNIT STARTING AND WORKING

WARNING: 

Never take the electronic board out of the control box.

The wiring diagram inside the terminal block will show you how to make correct connection.

Wrong connection will destroy the whole electronic circuit. Cable used for connection must be a 
three-wired one with compulsory grounding end. It shall have the outer diameter at 6 mm min and 9 
mm max. One of the leading end of the cable must be lower than the position of the fixing screws 
while the cable being connected to the power as shown in the fig.

The four screws on the panel board and the two nuts for fixing cable must be well fastened to avoid 
water entering into the control box and damaging the electronic circuit.

6. TECHNICAL DATA

Power: 1.1 kW
Current: 10 A
Maximum working pressure: 10 bar
Max working temperature: 60ºC
Connection: G1

male

Protection rating: IP54

contactor

contactor

Wiring diagram for

connection of single

-phase 220V pumps

up to 1.1 kW.

Wiring diagram for connection

of single-phase 220V pumps

over 1.1 kW. Through

remote control switch.

SPECIFICATIONS FOR

REMOTE CONTROL SWITCH

Minimum contacts capacity of

4 kW or 5.5 hp approx

220V

SPECIFICATIONS FOR

REMOTE CONTROL SWITCH

Minimum contacts capacity of

4 kW or 5.5 hp approx

220V

Wiring diagram for connection

of three phase 380V motor

pumps through remote control

switch.

L1-1-50-60 Hz 220-240V

L1-1-50-60 Hz 220-240V

L1-1-50-60 Hz 220-240V

TYPE OF DEFECT

- The pump does

not start

- The pump does

not stop

- Intermittent

pump working

- The pump is

jammed

- The electronic card is broken

- The electronic card is broken

- The flow detector is blocked in

the upper position

- The reset button is broken

- The pump does not provide

sufficient pressure

- The electronic card is broken

- The pump does not provide

sufficient pressure

- The electronic card is broken

- The pump provides a pressure

which is lower than the

restarting pressure

- Voltage failure

 - Pump is jammed

- Electric cables inverted

(line/motor)

-Presence of leaks which are

higher than the minimum

flow 2 L/min

- Presence of leaks which are

lower than the minimum

flow 2 L/min

- Water failure

- Suction problems

CAUSES DEPENDING

ON THE UNIT

CAUSES NOT DEPENDING

ON THE UNIT

3