Service manual SC-150
-64-
. If the TV set was on normal run mode before switching off, the microcontroller delivers horizontal drive voltage at pin
24 and picture appears on screen.
. If the TV set was on stand-by mode before switching off, the microcontroller switches TV set to stand-by mode,
decreasing power pin voltage (pin 1).
5-10-2 TV normal run and stand-by mode operations
Depending on remote control commands, I501 microcontroller part pin 1 (power) is set to :
- high for normal run mode
- low for stand-by mode
a) TV on normal run mode
* I501 microcontroller part pin 1 (power) effect
I501 microcontroller part pin 1 (power) is connected to the following circuit :
Summary of Contents for CHASSIS : SC-150 Model : DSC-3220E
Page 35: ...Service manual SC 150 34 Block diagram TDA6107Q...
Page 44: ...Service manual SC 150 43 5 Circuit description 5 1 Block diagram...
Page 62: ...Service manual SC 150 61 5 9 2 2 STR F6654 oscillating operation...
Page 82: ...Service manual SC 150 81 8 1 PCB MAIN...
Page 83: ...Service manual SC 150 82 8 2 PCB UNION...
Page 84: ...Service manual SC 150 83 9 1 Schematic Diagram MAIN...
Page 85: ...Service manual SC 150 84 9 2 Schematic Diagram UNION...
Page 86: ......