background image

 

MEASUREMENT AND TEST

1. MEASUREMENT OF THE MICROWAVE POWER OUTPUT 

M icrowave output pow er can be checked by indirectly m easuring the tem perature rise of a certain am ount of w ater exposed to 
the m icrow ave as directed below.

PROCEDURE

1. M icrow ave pow er output m easurem ent is m ade w it the m icrow ave oven supplied at rated voltage and operated at its 

m axim um  m icrow ave pow er setting w ith a load of 1000 ±  5cc of potable w ater.

2. T he w ater is contained in a cylindrical borosilicate glass vessel having a m axim um  m aterial thickness of 3 m m  and an outside

diam eter of approxim ately 190 m m .

3. T he oven and the em pty vessel are at am bient tem perature prior to the start of the test. T he initial tem perature of the w ater is

10 ±  2 ° C  (50 ±  3.6 ° F ). It is m easured im m ediately before the water is added to the vessel. A fter addition of the w ater to the

vessel, the load is im m ediately placed on the center of the shelf, w hich is in the low est norm al position.

4. M icrow ave pow er is sw itched on.
5. H eating tim e should be exactly A seconds 

(R efer to table as follow ing).
H eating tim e is m easured w hile the
m icrow ave generator is operating at
full pow er. The filam ent heat-up tim e 
for m agnetron is not included.

6. T he initial and final tem perature of w ater is 

selected so that the m axim um  difference 
betw een the am bient and final w ater tem perature
is 5K .

7. T he m icrow ave pow er output P  in w atts is calculated 

from  the follow ing form ula:

 

T is difference betw een initial and ending tem perature.

 

 t is the heating tim e.

T he  pow er  m easured  should  be  B   (R efer  to  S P E C IFIC ATIO N S )  W   ±   10.0  % .

 H eating tim e for pow er output:

A  (second)

70

64

60

56

52

49

47

44

42

40

38

B  (W )

600

650

700

750

800

850

900

950

1000

1050

1100

P  = 4187 x 

T/ t

CAUTION

1. W ater load should be m easured exactly to 1 liters.
2. Input pow er voltage should be exactly specified voltage (R efer to S P E C IF ICAT IO N S ).
3. A m bient tem perature should be 20 ±  2° C  (68 ±  3.6° F )

Summary of Contents for KOR-63671S

Page 1: ...Service Manual Microwave Oven Model KOR 63671S KOR 86671S DAEWOO ELECTRONICS CO LTD S M No R63671S001...

Page 2: ...ke repairs as necessary 1 Interlock operation 2 Proper door closing 3 Seal and sealing surfaces arcing wear and other damage 4 Damage to or loosening of hinges and latches 5 Evidence of dropping or ab...

Page 3: ...rtified oven unit is found to servicing a microwave emission check should be performed prior to servicing the oven a inform the manufacturer importer or assembler b repair the unit at no cost to the o...

Page 4: ...50W 950W MICROWAVE FREQUENCY 2450MHz OUTSIDE DIMENSIONS W X H X D 465 x 279 x 370 mm 18 3 x 11 0 x 14 6 in 495 x 294 x 403 mm 19 5 x 11 6 x 15 9 in CAVITY DIMENSIONS W X H X D 290 x 220 x 306 mm 11 4...

Page 5: ...ting 4 Oven cavity 5 Door seal Door seal maintains the microwave energy within the oven cavity and prevents microwave leakage 6 Glass cooking tray Made of special heat resistant glass Food in a proper...

Page 6: ...ith cable of special type which if damaged must be repaired with cable of same type Such a cable can be purchased from DAEWOO and must be installed by a Qualified Person 6 Examine the oven after unpac...

Page 7: ...it will turn off Oven light turns off If additional cooking time is needed and the door is closed the oven will automatically start when the timer is reset Variable power cooking On and OFF cycle time...

Page 8: ...pair work 2 Warning about the electric charge in the high voltage capacitor For about 30 seconds after the operation has stopped an electric charge remains in the high voltage capacitor When replacing...

Page 9: ...203830 FRAME DOOR ABS 1 A02 3517005610 BARRIER SCREEN 0 PMMA 1 5t 1 A03 3515306500 SUPPOTER BARR S 0 ABS 1 A04 3511603800 DECORATOR DOOR ABS 1 A05 3511706100 DOOR PAINTING AS KOR 61150S 1 A06 35170028...

Page 10: ...contact the door seal to oven front surface Tighten a screw 2 To reduce gap located on part B Loosen two screws on stopper hinge under and then push the door to contact the door seal to oven front sur...

Page 11: ...517400400 COUPLER TIMER POM 1 B08 3513405430 KNOB ABS 1 B09 3518205100 TIMER KN60MKD 12E P 1 B10 7122401211 SCREW TAPPING T2S TRS 4 12 MFZN 2 REF NO PART CODE PART NAME DESCRIPTION Q TY REMARK B01 351...

Page 12: ...7 Pull out the V P C coupler V P C knob and flat spring from the control panel 8 Remove the decorator c panel form the control panel 9 Reverse the above steps for reassembly 6 To remove high voltage c...

Page 13: ...pole 7 Remove the motor shaded pole 8 Reverse the above steps for reassembly 9 To remove H V transformer 1 Remove four screws holding the H V transformer 2 Remove the H V transformer 3 Reverse the abo...

Page 14: ...ing it under NO condition and the lock lever presses the button of the secondary interlock switch to bring it under ON condition 3 Adjustment steps 1 Loosen the one mounting screw 2 Adjust interlock s...

Page 15: ...turn the timer Does the fuse blow Check continuity of interlock monitor switch with door shut Replace primary secondary interlock switch and interlock monitor switch Replace fuse and check continuity...

Page 16: ...3V of high voltage Replace high voltage transformer Check the diode for continuity in the reverse and normal directions Replace high voltage diode Replace magnetron Replace magnetron Meter with 6V or...

Page 17: ...el the load is immediately placed on the center of the shelf which is in the lowest normal position 4 Microwave power is switched on 5 Heating time should be exactly A seconds Refer to table as follow...

Page 18: ...on the door cabinet door seem door viewing screen the exhaust air vents and the suction air vents 3 Measuring should be in a counter clockwise direction at a rate of 1 in sec If the leakage of the cab...

Page 19: ...he ohmmeter set on the highest resistance scale measure the resistance across the diode terminals Reverse the meter leads and again observe the resistance reading Meter with 6v 9v or higher voltage ba...

Page 20: ...WIRING DIAGRAM...

Page 21: ...EXPLODED VIEW AND PARTS LIST 1 DOOR ASSEMBLY Refer to Disassembly and assembly 2 CONTROL PANEL ASSEMBLY Refer to Disassembly and assembly 3 TOTAL ASSEMBLY...

Page 22: ...250V 12A 65TS O 4415D67120 FUSE 250V 12A MDA F12 3518606200 NOISE FILTER DWLF M12 O F13 7121403011 SCREW TAPPING T2S PAN 4X30 MFZN O F14 3963513100 MOTOR SHADED POLE 230V 17W OEM 100W X2 A07 O 3963512...

Page 23: ...0V 25W T25 C7A H187 O F39 7121400611 SCREW TAPPING T2S PAN 4X6 MFZN O F40 3966310100 MOTOR SYNCRO 220V 2 5W GM 16 24FD12 O 3966310110 MOTOR SYNCRO 220V 2 5W M2LJ49ZT52 O F41 3518905300 THERMOSTAT OFF...

Page 24: ...FUSE 250V 12A 65TS O 4415D67120 FUSE 250V 12A MDA F12 3518606200 NOISE FILTER DWLF M12 O F13 7121403011 SCREW TAPPING T2S PAN 4X30 MFZN O F14 3963513100 MOTOR SHADED POLE 230V 17W OEM 100W X2 A07 O 3...

Page 25: ...0V 25W T25 C7A H187 O F39 7121400611 SCREW TAPPING T2S PAN 4X6 MFZN O F40 3966310100 MOTOR SYNCRO 220V 2 5W GM 16 24FD12 O 3966310110 MOTOR SYNCRO 220V 2 5W M2LJ49ZT52 O F41 3518905300 THERMOSTAT OFF...

Page 26: ...LECTRONICS CO LTD 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC E mail G7F00E web dwe co kr FAX 02 360 8184 TEL 02 360 8179 8180 PRINTED DATE JU...