background image

No.

Part  Name

Quantity

Sale code

BOM code

Remark

1

Clamp for front net

8

10112121801

2113511801

2

Front net

1

10118121801

2124550017

3

Front clapboard

1

10924121801

2124550030

4

Propeller fan

1

10118121804

2114550002

5

Fan motor

1

11321111801

2240043104

6

Holder for fan motor

1

10118121809

2124550020

7

Foam over holder for motor

1

10118121807

2224550001

8

Cover

1

10118121827

2124550031

9

Little handle

1

10830121811

2115029006

10

Condenser

1

11330113801

2153549090

11

Support board for motor holder

1

10924121807

2124550029

12

Left clapboard

1

10924121808

2124550032

13

Rear net

1

10924121809

2114550004

14

Rear right clapboard

1

10118113804

2123549024

15

Big handle

1

10118121817

2114550003

16

Installation plate for valves

1

10118113805

2123500018

17

Water collector

1

10118121832

2113529005

18

Fan motor capacitor

1

10118121821

2240110504

19

Wire joint for multiplexer

1

10121121809

2230145035

20

Separating board

1

10118121812

2123530550

21

Installation board for E-parts

1

10424121802

2123541204

22

Contactor

1

10121121806

2230085004

23

Wire joint

1

10224111803

2230145004

24

Washer for wire joint

1

10112121817

2113500004

25

Clamp for wiring

1

10118121823

2124540027

26

Compressor capacitor

1

10122123801

2240100805

27

Capacitor clamp

1

10112121814

2120010002

28

Chassis

1

10121121802

2124550008

29

Front right clapboard

1

10118121819

2124551104

30

Compressor

1

30324311005

2140160320

QP442PBA

31

Liquid valve assy

1

11330111004

2163549491

32

Liquid pipe valve

1

10124121812

2160074223

33

Gas valve assy

1

11321113801

2163549454

34

Gas pipe valve

1

11321111804

2160072220

35

Copper nut, TLM-B02

1

10909121013

2160032001

36

Copper nut, TLM-D04

1

11324113804

2160032003

23

Summary of Contents for DSB-300L

Page 1: ...B 300LH S M NO DSB300LH001 Aug 2005 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please...

Page 2: ...1 FEATURES 2 2 SPECIFICATIONS 4 3 OUTLINE AND DIMENSIONS 5 4 REFRIGERATION CYCLE DIAGRAM 6 5 OPERATION LIMITS 8 6 WIRING DIAGRAM 9 7 TROUBLESHOOTING 13 8 ELECTRONIC CONTROL 14 9 EXPLODED VIEW PARTS 20...

Page 3: ...e are integrally designed and of easy installation 1 3 The front panel is tightly fixed with the front frame by simply buckling the latter with a buckle mechanism on the panel 1 4 The manual force swi...

Page 4: ...2574 Rated current RLA A 12 5 12 5 Locked rotor Amp LRA A NOT FIXED NOT FIXED Thermal protector Internal Internal Capacitor uF 55 55 Refrigerant oil ml 700 700 Indoor fan motor Model YDK32 4 YDK32 4 B...

Page 5: ...nd type mm 9 53 innergroove tube 9 53 innergroove tube f Coil length x height x width mm 775X660X44 775X660X44 g Number of circuits 4 4 Outdoor air flow m3 h 2500 2500 Outdoor noise level dB A 62 62 O...

Page 6: ...5 3 OUTLINE AND DIMENSIONS...

Page 7: ...Heating and cooling DSB 300LH 6 4 Refrigeration cycle diagram...

Page 8: ...7 Cooling only DSB 300L...

Page 9: ...he continuous operation under constant air temperature conditions However excludes the initial pull down stage Heating operation Note The chart is the result from the continuous operation under consta...

Page 10: ...6 WIRING DIAGRAM DSB 300L Indoor Unit...

Page 11: ...10 DSB 300L Outdoor Unit...

Page 12: ...11 DSB 300LH Indoor Unit...

Page 13: ...12 DSB 300LH Outdoor Unit...

Page 14: ...rs at 5Hz Defrosting indicator flickers at 5Hz Defrosting indicator auto indicator flicker at 5Hz Auto indicator indicator flicker at 5Hz Four times Current protection PRCUR1 5Hz the room temperature...

Page 15: ...tion only for heat pump Condition Compressor Outdoor fan Temp up T Ts 1 On On T Ts 1 Off Off Temp down T Ts On On T Ts Off Off Temp Condition Compressor Temp up T TE10 Off T TE10 On Temp down T TE11 O...

Page 16: ...valid 8 4 4 Indoor Fan actions at heating mode Indoor Fan can be set at HIGH MID LOW AUTO by using a remote controller Anti cold wind function 1 Anti cold air protection 2 when the room temp satisfy...

Page 17: ...E9 Off Off temp down T TE9 On On 8 5 Defrosting mode 8 5 1 Conditions of defrost Defrosting starts when either of the following T3 lower than 0 c lasts for more than 40 minutes provided that the time...

Page 18: ...will maintain as a constant and the air circulation is kept at low speed Cold air proof function takes priority over all 8 6 2 At auto mode the indoor fan blows automatically in selected mode 8 6 3 On...

Page 19: ...or Protection against low temperature If any of the protection functions the comparative protecting action is executed The forced cooling mode is closed by one touch on the button meanwhile the operat...

Page 20: ...speed On On Cooling mode IFAN I I5MIN Off Off After 5 Minutes I5MIN I I3SEC Off Off After 3 Seconds Current down I5MIN I I3SEC Off Off After 3 Seconds IFAN I I5MIN Off Off After 5 Minutes IRESTORE I I...

Page 21: ...20 9 Exploded View Parts DSB 300L 220 240V 50Hz Indoor Unit...

Page 22: ...er down 1 10121121221 2113070017 19 Supporting board for chassis II 1 10121121222 2113070037 20 Fan motor 1 10121121223 2240040501 21 Right cross flow fan assy 1 10121121224 2113070058 22 Indoor temp...

Page 23: ...22 DSB 300L 220 240V 50Hz Outdoor Unit...

Page 24: ...05 2123500018 17 Water collector 1 10118121832 2113529005 18 Fan motor capacitor 1 10118121821 2240110504 19 Wire joint for multiplexer 1 10121121809 2230145035 20 Separating board 1 10118121812 21235...

Page 25: ...24 DSB 300LH 220 240V 50Hz Indoor Unit...

Page 26: ...er down 1 10121121221 2113070017 19 Supporting board for chassis II 1 10121121222 2113070037 20 Fan motor 1 10121121223 2240040501 21 Right cross flow fan assy 1 10121121224 2113070058 22 Indoor temp...

Page 27: ...26 DSB 300LH 220 240V 50Hz Outdoor Unit...

Page 28: ...13805 2123500018 17 Water collector 1 10118121832 2113529005 18 Fan motor capacitor 1 10118121821 2240110504 19 Wire joint for multiplexer 1 10121121809 2230145035 20 Separating board 1 10118121812 21...

Page 29: ...DAEWOO ELECTRONICS CORP 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC PRINTED DATE Aug 2005...

Reviews: