14
8
ELECTRONIC CONTROL
8.1 Fan only mode
Fan speed is high/mid/low/ Auto
8.2 Cooling mode
The 4-way valve is closed at cooling mode.
The action of the compressor and the outdoor fan:
T: Room temp.
Ts: Setting temp.
Auto fan
Anti-freezing control to indoor evaporator
Condenser high temp. protection( only for heat pump)
Condition
Compressor
Outdoor fan
Temp. up
T> Ts+1
On
On
T<Ts+1
Off
Off
Temp. down
T> Ts
On
On
T<Ts
Off
Off
Temp. Condition
Compressor
Temp. up
T> TE10
Off
T< TE10
On
Temp. down
T> TE11
Off
T< TE11
On
Condition
Compressor
Outdoor fan
Temp.
Time
Temp. up
T> TE6
On
On
T< TE6
>4 Minutes
Off
Off
Temp. down
T> TE5
On
On
T< TE5
>4 Minutes
Off
Off
Condition(T=Indoor Temp.-Setting Temp.)
Indoor fan speed
Temp. up
T<1°C
Low
1°C<T<4°C
Med.
T>5°C
High
Temp. down
T> 4°C
High
1°C<T<4°C
Med.
T<1°C
Low