19

Installation Instructions

FAN

LIGHTS

TIMER

Feature-Button Panel

Filter

Grease channel

Verifying the Setup

1.  Turn OFF the main power switch.

2.  Turn power ON at the circuit panel or fusebox.
3.  Turn ON the main power switch.

The button panel flashes several times during startup.

4.  Insert the filters gently:

a.  Do not scratch the back of the grease channel!
b.  Set the front edge into the clip, and press forward.

OFF

ON

c.  (Taking care not to scratch the grease channel or 

other hood/filter surfaces) Lift the rear edge above 

the grease channel.

d.  Set the filter rear edge onto the grease channel.

5.  On the hood feature-button panel, press the 

LIGHTS

 

button to verify that all lights turn on.

6.  Press the 

LIGHTS

 button again to turn the lights to the 

Low setting.

7.  Press the 

LIGHTS

 button again to turn the lights off.

8.  Press/release the 

FAN

 button to verify that one fan-

speed indicator turns on 

and

 the fan is on at low speed. 

9.  Slowly press/release the 

FAN

 button three times:

a.  to verify that the number of lights and fan speed 

increases each time, then

b.  press the 

FAN

 button again to turn the fan OFF

If the Hood Fails to Function Correctly:

1.  Verify that power is supplied to the hood.
2.  Remove the right-most filter to access the main power 

switch behind the button panel, and confirm the main 

power switch is ON.

3.  Verify that the electrical connections are correctly done.
4.  Perform the 

Verify the Setup

 procedure again.

 IMPORTANT

If the hood still does not work, contact Dacor Distinctive 

Service: (800) 793-0093 x2822. Do not try to repair the 

appliance yourself. Dacor is not responsible for service 

required to correct a faulty installation.

Installation Checklist

 WARNING

•  To ensure a safe and correct installation, this checklist 

should be completed by the installer to ensure com-

plete and proper installation.

•  The homeowner is responsible for the Dacor range 

hood’s proper installation, the importance of which can-

not be overstated.

 

The hood is properly attached to the wall per the instruc-

tions on Pgs. 11 and 16.

 

Ducting is fully installed; joints are secured with sheet-

metal screws and wrapped with foil tape. See Pg. 19.

 

The hood is wired/grounded as instructed and per all 

applicable electric codes. See Pgs. 7, 19.

 

Filters are assembled as instructed on Pg. 18.

 

The setup was verified.

 

Any problems were noted on the warranty card or during 

the online warranty activation. The warranty card was 

completed and mailed, or the warranty activated online.

Main Power 

Switch Detail/

Hood Bottom

Summary of Contents for RNHE36

Page 1: ...Models RNHP30 36 48 Models RNHE30 36 48 Part No 109172 Rev B APPROVED FOR USE WITH ALL DACOR RANGES AND COOKTOPS TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI UL 507 STANDARD FOR ELECTRIC FANS...

Page 2: ...m 5 00 p m Pacific Time Appliance Data Plate This label contains the model and serial number and electrical requirements The data plate is inside the hood above the filters on the chassis back wall R...

Page 3: ...amage personal injury or death WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If y...

Page 4: ...into the hood To avoid a fire hazard If the appliance is by a window do not use window coverings that could blow over the cooking surface and hood Use only metal ducting Always run the hood fans when...

Page 5: ...bulbs Individual Models RNHP RNHE Components 48 36 30 Lights 4 3 2 Filters 4 3 2 Blowers 2 1 1 Exhaust Vents 2 1 1 Blower Rating 1200 CFM 600 CFM 600 CFM Product Specifications Individual Models RNHP...

Page 6: ...he top or rear of the hood Before installing the hood mark the access holes according to the diagrams below Tolerances 1 16 0 unless otherwise stated Rear Connections All Models Model A B C 48 1 1 2 i...

Page 7: ...pecifications Dimensions Tolerances 1 16 0 unless otherwise stated Dual Blower RNHP48 Series RNHP Hood Dimensions Single Blower RNHP30 36 Series Dual Blower RNHE48 Series Single Blower RNHE30 36 Serie...

Page 8: ...a licensed electrician installs the electrical service to the range hood The owner is responsible for verifying that all electrical requirements are met by the qualified electrician servicing this app...

Page 9: ...d mini mums Dimensions given are minimum clearances unless other wise noted All contact surfaces between the hood and cabinetry walls must be sturdy solid and at right angles Install the hood and cook...

Page 10: ...NG During duct installation ensure the damper flaps on top of the hood can open freely Planning the Ductwork WARNING To prevent combustion by products smoke or odors from entering the home and to impr...

Page 11: ...If existing ductwork is less than 8 inches in diam eter replace it with 8 ductwork Connect all ducting sections with sheet metal screws then seal with certified duct foil tape Never connect joints wi...

Page 12: ...10 Preparation and Setup Models RNHP RNHE Weight 3012 51 lbs 23 kg 3018 3612 53 lbs 24 kg 3618 57 lbs 26 kg 4812 70 lbs 32 kg 4818 77 lbs 35 kg Support Structures Within Wall Mounting Block...

Page 13: ...nt in cm A 9 7 8 in 25 08 cm B 14 1 8 in 35 88 cm C 48 in 121 92 cm D 24 in 60 96 Rear Exhaust Centerline IMPORTANT Users of the dual exhaust format will need to install the AHT10 Dual to Single Trans...

Page 14: ...d technician may install this built in appli ance Multiple persons are needed to lift the hood into place The owner shall verify proper installation Top Exhaust Rear Exhaust The blowers fans can be ro...

Page 15: ...installed Disassembling Parts 1 Unhook and remove the grease channel 2 Taking care not to scratch the hood Place the hood as sembly on a large flat surface 3 Remove the duct collar from the hood top...

Page 16: ...e it with this graphic Blower I O port on right when facing back of hood Back of Hood Front of Hood Bottom of Hood Blower tip extends here Replacement Part Description 702579 Baffle Filter Kit 1 pc ha...

Page 17: ...exhaust models the two 8 duct exhausts can be transitioned into one 10 duct Assemble the Dacor transition kit AHT10 sold separately before you hang the hood This transition kit fits over the top rear...

Page 18: ...10 unit to the hood 4 With foil tape duct tape seal the AHT10 unit s base Installation Instructions Unbent flange overlaps top of hood Rear Vent Configuration Hanging the Range Hood WARNING Hanging th...

Page 19: ...r Miswiring the hood s electrical wiring can cause an electric shock or fire hazard and could damage the hood s electrical system See Pgs 17 19 Do not ground the wires to the neutral white wire Connec...

Page 20: ...No 4 copper wire Inserting Light Bulbs Be sure to use dimmable bulbs The electronic board was designed for dimmable lights Using non dimmable bulbs causes damage and faulty performance Before changin...

Page 21: ...Verify that power is supplied to the hood 2 Remove the right most filter to access the main power switch behind the button panel and confirm the main power switch is ON 3 Verify that the electrical co...

Page 22: ...20 Wiring Diagrams RNHP3012 3018 RNHE3012 3018 Wiring Diagram 1 Blower 2 Light Models...

Page 23: ...21 Wiring Diagrams RNHP3612 3618 RNHE3612 3618 Wiring Diagram 1 Blower 3 Light Models...

Page 24: ...22 Wiring Diagrams RNHP4812 4818 RNHE4812 4818 Wiring Diagram 2 Blower 4 Light Models...

Page 25: ...23 Notes...

Reviews: