background image

1

Important Information About 

Safety Instructions

• The 

Important Safety Instructions

 and warnings in this

manual do not cover all possible issues. Use common

sense and caution when installing, maintaining, or operat-

ing the appliance.

• Contact Dacor Customer Assurance about issues

and conditions you cannot resolve. (See 

Customer

Assurance Information

.)

Important Safety Instructions

Safety Symbols and Labels

 DANGER

Immediate hazards that 

WILL

 result in severe personal 

injury or death.

 WARNING

Hazards or unsafe practices that 

COULD

 result in severe 

personal injury or death.

 CAUTION

Hazards or unsafe practices that 

COULD

 result in minor 

personal injury or property damage.

 WARNING

The unit has a 3-prong grounding plug to protect against 

electric shock. It must plug into a dedicated, 3-prong, 

grounded outlet. The owner shall ensure that such an 

outlet is available for the appliance. 

Do not:

• remove the third (ground) prong from the power cord.
• use an adapter plug.
• use an extension cord.
• use a damaged power cord.
• Use a ground fault interrupter (GFI).

 DANGER

Do not store/use combustible, flammable substances 

(e.g., gasoline, alcohol, benzene) in/on/near the vent.

 WARNING

TO REDUCE RISK OF PROPERTY DAMAGE AND 

PERSONAL INJURY, OBSERVE THE FOLLOWING:

a) Installation work and electrical wiring must be done by

qualified person(s) per applicable codes, including

fire-rated construction.

b) Sufficient air is needed for proper combustion and

exhaust of gases via the flue of fuel-burning equipment

to prevent backdraft. Follow manufacturer guidelines

such as are published by the National Fire Protection

Association (NFPA); the American Society for Heating,

Refrigeration, and Air Conditioning Engineers

(ASHRAE); and local code authorities.

c) Know the location of wiring and piping before cutting

or drilling into a wall or ceiling.

d) Fans must always vent to the outdoors.

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for MRV3615S

Page 1: ...V48S Includes installation instructions for Dacor cabinet blower CABP3 which is an option for the indicated models Part No 113910 Rev C Use these downdraft vents only with approved Dacor appliances Se...

Page 2: ...ep these installation instructions for future reference and the local electrical inspector s use Customer Assurance Information All specifications subject to change without notice Dacor assumes no lia...

Page 3: ...an outlet is available for the appliance Do not remove the third ground prong from the power cord use an adapter plug use an extension cord use a damaged power cord Use a ground fault interrupter GFI...

Page 4: ...s become blocked Do not let foreign objects be sucked into vent holes Clean the filters and all grease laden surfaces often to pre vent grease fires and maintain performance Clean the appli ance only...

Page 5: ...for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum specified counter height for cooking appliance See installation instructions for cooking appliance Total c...

Page 6: ...own Tolerances 1 16 1 6 mm unless otherwise stated See Pg 9 for exhaust locations dimensions Max height of downdraft must not exceed cooking unit s max specified counter height See cooking unit s inst...

Page 7: ...or legs 2 13 16 7 1 cm 1 4 6 mm Top cap with vent down Tolerances 1 16 1 6 mm unless otherwise stated Model Number Top Cap Width A Chassis Width B MRV36 ERS 36 91 4 cm 33 3 8 84 8 cm MRV48 ERS 48 121...

Page 8: ...f the downdraft vent for connecting blower wiring and strain relief Wire the blower to turn on when the downdraft vent is turned on When installing a remote or in line blower run the blower wiring con...

Page 9: ...de wall Downdraft vent Downdraft vent configured for bottom exhaust Floor Wiring conduit from downdraft to in line blower Cabinet back Front of unit Connection to cabinet blower Blower wiring access h...

Page 10: ...raft vent s air draw Building codes may require makeup air systems with ven tilation systems that move air greater than the specified movement rate CFM Consult a qualified HVAC specialist when designi...

Page 11: ...ne of bottom knock out lines up with vertical center line of chassis On 30 and 36 wide models the vertical center line of bottom knock out is offset 3 Side Exhaust Knock Outs 1 5 8 x 16 Bottom Exhaust...

Page 12: ...onnection center line A Downdraft vent center line Countertop 3 1 4 x 10 duct connection 26 1 4 66 7 cm Exhaust Locations and Side Dimensions for CABP3 Cabinet blower Front Exhaust Dimensions CABP3 Bl...

Page 13: ...e above parts is 15 ft 15 ft 4 ft 2 ft 36 ft The max amount of straight duct that can be used with a REMP16 and the above parts is 60 ft 34 ft 24 ft Equivalent Number of Feet Nominal Duct Elbows and T...

Page 14: ...cooktop Install the down draft vent before installing the range or cooktop 2 Start by loosely attaching the anchoring legs to the studs on the left and right sides of the downdraft vent using the prov...

Page 15: ...wing nuts and 3 flat washers on the front of the unit Discard the 3 lock washers whilch will be replaced Tilt the cover out and pull up to remove it 2 Peel the backing off of some of the foam tape in...

Page 16: ...m to right left flanges Adapter New label Existing label ILHSF or REMP Series Blower Installation If using a ILHSF or REMP series blower install it according to the blower installation instructions Du...

Page 17: ...cal Installation CABP3 Cabinet Blower Downdraft Vent Electrical Access Panel Front of unit Wire Colors Black Line L White Neutral N Green Ground Gnd Electrical connection from downdraft vent match Wir...

Page 18: ...aft vent Ensure the downdraft vent supplies power to the blower If the vent will not raise properly or makes a scraping sound check for under counter obstructions If the downdraft vent fails to functi...

Page 19: ...LK WHT WHT Wiring Diagram All Models CABP3 Cabinet Blower Ratings CABP3 Cabinet blower Airflow Nominal 600 CFM Actual 585 6 CFM At zero inches static pressure Performance varies based on duct system c...

Page 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: