Page 2

21"

(533mm)

4" (102mm)

"A"

Model 

"A"

IHL30 

27" (686mm)

IHL36 

33" (838mm)

IVS1 Mounting

studs (typ)

IVS1 Power Pack

IHL Mounting

hole (typ)

STEP 1

Installation Planning

The Dacor Integrated Hood Liner (IHL) is constructed with non-combustible stainless steel material. The IHL dimensions and installation 

design technique makes this an excellent component for any custom hood structure. In addition Dacor offers two Power Pack products (IVS1 

and IVS2) which conveniently install on the pre-mounted installation lugs around the Power Pack opening at the top of the hood liner.

Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum clearances, unless otherwise 

noted.

Figure 1:

IHL30/36 Overall Dimensions

Top View

NOTES: 

1.  Dacor Integrated Hood Liners have no electrical parts.

2.  If utilizing Dacor Power Packs follow all electrical requirements listed within the Power Pack 

installation instructions.

3.  The Integrated Hood Liner has been designed for vertical on center ducting applications only.

4.  For proper installation of the complete IHL/IVS custom hood ventilation system the installer 

must follow the IVS Power Pack planning and installation information noted in the IVS 

installation instructions.

21"

(533mm)

4" (102mm)

"B"

Model 

"B"

IHL42 

39" (991mm)

IHL48 

45" (1143mm)

IHL54 

51" (1295mm)

IVS2 Mounting

studs (typ)

IVS2 Power Pack

IHL Mounting

hole (typ)

Figure 2:

IHL42/48/54 Overall Dimensions

Top View

NOTE: 

  The IHL30 and IHL36 liners are designed 

for installation with the 600CFM 

IVS1 Power Pack. For additional 

specifications refer to the IVS planning 

guide or installation instruction.

NOTE: 

  The IHL42, IHL48 and IHL54 liners 

are designed for installation with 

the 1200CFM IVS2 Power Pack. 

For additional specifications 

refer to the IVS planning guide or 

installation instruction.

Summary of Contents for IHL42

Page 1: ...r to operating this appliance TABLE OF STEPS STEP 1 Planning the installation Page 2 STEP 2 Electrical connections Page 3 STEP 3 Installing the IHL Page 3 STEP 4 Verifying proper operation Page 3 Part No 65268 Rev A NOTES Contain helpful hints and tips to facilitate the installation CONVENTIONS USED IN THESE INSTRUCTIONS IMPORTANT Must be followed carefully to avoid damage WARNINGS Must be followe...

Page 2: ......

Page 3: ...at oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNINGS TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERV...

Page 4: ...cal parts 2 If utilizing Dacor Power Packs follow all electrical requirements listed within the Power Pack installation instructions 3 The Integrated Hood Liner has been designed for vertical on center ducting applications only 4 For proper installation of the complete IHL IVS custom hood ventilation system the installer must follow the IVS Power Pack planning and installation information noted in...

Page 5: ...ubleshooting steps 1 Verify that power is being supplied to the power pack 2 Check the electrical connections to ensure that the installation has been completed correctly 3 Repeat the above test 4 If the appliance still does not work contact an authorized DACOR service company at 800 772 7778 or at www dacor com Do not attempt to repair the appliance yourself 5 DACOR is not responsible for service...

Page 6: ...Page 4 NOTES ...

Page 7: ......

Page 8: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093 ...

Reviews: