5
13 in max.
3
(33.0 cm)
3
Not applicable for cabinets more than a horizontal distance of 6 in.
(15.2 cm) from edge of cooktop. Allow 7 1/2 in
(19.1 cm)
from edge
of cutout.
A
See cutout
dimensions
15 in min.
1
,
3
(45.7 cm)
1 7/8 in min.
(4.8 cm)
Combustible
surface to rear
Combustible overhead
cabinets
30 in min.
1
,
2
(76.2 cm)
7 1/2 in (19.1 cm) min. to
combustible side wall,
above counter (on both sides)
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
1
Measured from top of cooktop grate.
All tolerances:
±
1/16”
unless otherwise noted.
Cabinet/Countertop Layout
WARNING
• To reduce the risk of burn injury, avoid installing cabi-
nets above the cooktop.
• Not meeting or exceeding the maximum and minimum
dimensions/clearances in these instructions may result
in a fire hazard.
• Follow the countertop manufacturer’s instructions con-
cerning minimum corner radius, use of heat-reflective
tape, corner reinforcement, etc.
•
For best performance, the cooktop should not be
placed where it can be affected by drafts (doors, win-
dows, heating and air-conditioning outlets).
•
The cooktop is to be paired with a suitable vent hood or
approved Dacor downdraft.
CLEARANCE REQUIREMENTS
Model
A: Minimum
A: Recommended
HPCT466G
46 in (121.9 cm)
54 in (137.2 cm)
Installation Specifications
Under-Chassis Clearance/Allowances
Allow at least 1/4” (6 mm) between the chassis bottom and
all combustible surfaces (incl. edges/corners of drawers
below the cooktop).
1/4” (6 mm)
min. clearance
to combustible
surfaces
B
Model
B (Min. clearance for hold-down brackets)
HPCT466G
45 1/4 in (114.64 cm)
• Placement of gas-supply piping, gas shut-off valve, and
the electrical outlet must not impede cooktop installation.
• If installing an appliance below the cooktop, plan for rout-
ing of gas and power behind the appliance.
• The gas shut-off valve and regulator must remain acces-
sible after the unit is installed.
• The 40-in. (101.6 cm) power cord must reach an electri-
cal outlet; the outlet must be accessible after the cooktop
is installed.
• The chassis bottom must be accessible for service. (Do
not install a fixed shelf below the cooktop.)
• Leave space inside the cabinet for proper installation of
hold-down brackets.
See the following pages for countertop cutout dimensions.
Downdraft Compatibility
If installing the cooktop with a downdraft, use only these
approved Dacor model numbers:
Model
Corresponding Approved Downdraft Models
HPCT466G
PRV46, RV46