background image

6

Installation Specifications

Planning the Installation

General System Layout

The vent system consists of the downdraft vent itself and a 

single Dacor approved cabinet blower (models ERV3015 and 

ERV3615), remote blower or in-line blower (see facing page 

for examples).

 WARNING

•  Failure to install an approved blower or proper duct 

work will result in a back draft and/or the insufficient 

venting of smoke and fumes.

•  To reduce the risk of personal injury caused by reach-

ing over a hot appliance, cabinet storage space 

located directly above the range/cooktop should be 

avoided.

•  Follow the instructions and diagrams for minimum safe 

clearances and installation location in these instruc-

tions, the appliance installation instructions and the 

blower installation instructions. Failure to do so may 

result in a fire or safety hazard.

•  Plan the installation so that all minimum dimensions 

are met or exceeded. All contact surfaces between the 

downdraft vent and any cabinets or walls must be solid 

and at right angles.

•  The downdraft vent is equipped with adjustable anchor 

legs to accommodate various cabinet heights.

•  Install the downdraft vent and range/cooktop so that 

they can be removed if service is required.

•  When installing the downdraft vent with a cooktop, 

access from the front of the cabinet to the chassis and 

the electrical/gas supplies of both appliances must 

be provided for inspection and service. Any drawers 

or shelves must be easy to remove for access to the 

cooktop, downdraft vent and utilities.

•  There are 7/8” access holes in the bottom and side of 

the downdraft vent for connecting the blower wiring and 

strain relief. Wire the blower to turn on when the down-

draft vent is turned on. When installing a remote or in-

line blower, run the blower wiring/conduit parallel to the 

duct work, connecting it to the downdraft vent on one 

end and the blower on the other.

•  Allow room for the exhaust duct coming out of the unit. 

See 

Planning the Duct Work

 for further details.

•  The maximum allowable duct run must be taken 

into consideration when determining the layout. See 

Planning the Duct Work

 for further details. 

•  Refer to the range/cooktop installation instructions for 

the minimum cutout dimensions specific to the particu-

lar downdraft vent model being installed.

Vertical

non-combustible

surface rear wall

Notches for self-rimming

style installations, see range 

installation instructions

Notches required for some downdraft vent

installations, see range 

installation instructions

Backsplash

Countertop

overhang

See the range installation 

instructions for exact countertop 

and cabinet dimensions

Vertical

non-combustible

surface rear wall

Notches required for some downdraft vent

installations, see cooktop 

installation instructions

Backsplash

Countertop

overhang

See the cooktop installation 

instructions for exact countertop 

and cabinet dimensions

Flush with back side

of cabinet front

Range Cabinet/Countertop Cutout - top View

Cooktop Cabinet/Countertop Cutout - top View

Summary of Contents for ERV3015

Page 1: ...RV46 Part No 107736 Rev B Use these downdraft vents only with approved Dacor appliances See the installation instructions for the particular appliance model being installed to determine suitability Includes installation instructions for cabinet blower Dacor model CABP3 which is an option for models ERV3015 and ERV3615 ...

Page 2: ...Service Team For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line Whenever you call have the model and serial number of the appliance ready The model and seri al number are printed on the product data label on the front of the unit The product data label also specifies the power sup ply requirements Dacor Customer Service Phone 800 793 0093 ex 2813 U S A and Canad...

Page 3: ...rom the power cord Use an adapter plug Use an extension cord Use a power cord that is frayed or damaged Use of a ground fault interrupter GFI is not recommended DANGER IMPORTANT Do not store or use combustible flammable or explosive vapors and liquids such as gasoline inside or in the vicinity of this or any other appliance Also keep items that could explode such as aerosol cans away from the rang...

Page 4: ... not tamper with the controls Never allow the filters or vent openings to become blocked or clogged Do not allow foreign objects such as cigarettes or napkins to be sucked into the vent holes Clean the filters and all grease laden surfaces often to prevent grease fires and maintain performance Clean this appliance only as specified in the use and care manual Do not leave children or pets alone or ...

Page 5: ... 1 4 94 6 cm Adjustable anchor legs Product data label Tolerances 1 16 1 6 mm unless otherwise stated Model Number A Top Cap Width B Chassis Width ERV3015 30 76 2 cm 27 3 8 69 5 cm ERV3615 36 91 4 cm 33 3 8 84 8 cm See pages 9 and 10 for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum specified counter height for cooking appliance See installation instruct...

Page 6: ... mm Top cap with vent down Tolerances 1 16 1 6 mm unless otherwise stated Model Number A Top Cap Width B Chassis Width ERV48 48 121 9 cm 43 3 8 110 2 cm PRV30 30 76 2 cm 27 3 8 69 5 cm PRV36 36 91 4 cm 33 3 8 84 8 cm PRV46 46 116 8 cm 43 3 8 110 2 cm See page 9 for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum specified counter height for cooking applian...

Page 7: ...unit 6 15 2 cm 2 9 16 6 5 cm 2 1 2 6 4 cm 1 15 16 4 9 cm B A Adjustable anchor legs 2 13 16 7 1 cm 1 4 6 mm Top cap with vent down Tolerances 1 16 1 6 mm unless otherwise stated Model Number Top Cap Width A Chassis Width B ERV36 ER 36 91 4 cm 33 3 8 84 8 cm ERV48 ER 48 121 9 cm 43 3 8 110 2 cm See page 9 for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum ...

Page 8: ...ion and service Any drawers or shelves must be easy to remove for access to the cooktop downdraft vent and utilities There are 7 8 access holes in the bottom and side of the downdraft vent for connecting the blower wiring and strain relief Wire the blower to turn on when the down draft vent is turned on When installing a remote or in line blower run the blower wiring conduit parallel to the duct w...

Page 9: ... conduit from downdraft to remote blower Cabinet blower option on ERV3015 and ERV3615 only Cooktop Floor 12 min 30 5 cm 3 1 4 x 10 90 elbow Wall Downdraft vent Wall cap Backsplash ILHSF series in line blower 3 x 10 to round transition Duct work Duct work Outside wall Range Wall cap on outside wall Downdraft vent Downdraft vent configured for bottom exhaust Floor Wiring conduit from downdraft to in...

Page 10: ...y require the use of makeup air systems with ventilation systems that move air greater than the specified movement rate CFM The specified rate var ies based on locale Consult a qualified HVAC specialist when designing the system for the requirements in your area and to assure optimal performance You must install one of the Dacor blower models listed below for the downdraft vent to operate properly...

Page 11: ...knock out lines up with vertical center line of chassis On 30 and 36 wide models the vertical center line of bottom knock out is offset 3 Side Exhaust Knock Outs 1 5 8 x 16 Bottom Exhaust Knock Out 1 5 8 x 16 Motor cover Front of unit 26 66 0 cm 6 1 4 15 9 cm 1 1 8 2 9 cm C L C L C L Exhaust Knock out Locations for Use with REMP and ILHSF Series Blowers Use sheet metal screws as required to suppor...

Page 12: ... Countertop 3 1 4 x 10 duct connection Duct connection center line B Downdraft vent center line Countertop 3 1 4 x 10 duct connection 15 3 8 39 1 cm Duct connection center line A Downdraft vent center line Countertop 3 1 4 x 10 duct connection 26 1 4 66 7 cm Exhaust Locations and Side Dimensions for CABP3 Cabinet blower Exhaust Locations and Dimensions for CABP3 Cabinet Blower Installations ERV301...

Page 13: ...t 2 feet 36 feet The maximum amount of straight duct that can be used with a REMP16 and the above components is 60 feet 34 feet 24 feet Equivalent Number of Feet Nominal Duct Elbows and Transitions 45 elbow 8 inch 3 feet 3 x 10 45 elbow 7 feet 45 elbow 10 inch 2 feet 3 x 10 90 elbow 15 feet 90 elbow 8 inch 7 feet 3 x 10 90 flat elbow 20 feet 90 elbow 10 inch 5 feet 3 x 10 to 8 round transition 4 f...

Page 14: ... cut out separate from the range or cooktop Install the down draft vent before installing the range or cooktop 2 Start by loosely attaching the anchoring legs to the studs on the left and right sides of the downdraft vent using the provided Keps nuts and washers Installation Preparation for Downdraft Vent with ILHSF or REMP Series Blower NOTE For units using the CABP3 cabinet blower skip to Instal...

Page 15: ...he three 3 wing nuts and three 3 flat washers on the front of the unit Discard the three 3 lock wash ers they will be replaced Tilt the cover out and pull up to remove it 2 Peel the backing off of some of the foam tape included with the adapter Attach it to the right and left flanges 3 Hold the adapter in front of the opening on the front of the unit with the adapter s studs on top and all the fla...

Page 16: ... the blower installation instructions Duct Work Installation warning Tape all duct joints securely to prevent combustion by products smoke or odors from entering the home Doing so will also improve system efficiency Install the duct work according to the Installation Specifications section Use sheet metal screws and duct tape to connect and seal all of the pieces Support the duct weight as necessa...

Page 17: ...ical Installation CABP3 Cabinet Blower Downdraft Vent Electrical Access Panel Front of unit Wire Colors Black Line L White Neutral N Green Ground Gnd Electrical connection from downdraft vent match Wire Colors CABP3 cabinet blower Downdraft vent blower wiring access hole Ground Power Input Blower Output Blower power wiring conduit Connect other end of wires to blower terminal block Wires to power ...

Page 18: ...hat power is being supplied to the unit Make sure that power is being supplied to the blower from the downdraft vent If the vent will not raise properly or makes a scraping sound check for obstructions interfering with the raising of the unit If the downdraft vent still does not function after perform ing the above checks do not attempt to repair it yourself Contact Dacor Distinctive Service at 79...

Page 19: ...BLK WHT WHT Wiring Diagram All Models CABP3 Cabinet Blower Ratings CABP3 Cabinet blower Airflow Nominal 600 CFM Actual 585 6 CFM At zero inches static pressure Performance varies based on duct system configuration Electrical Rating 4 Amps 120 Vac 60 Hz For ILHSF or REMP series blower ratings see the blower installation instructions Airflow CFM Cubic feet minute Static pressure inches of water 0 1 ...

Page 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Reviews: