14
Installation Instructions
Cabinet Blower Installation:
(optional, ERV3015 and ERV3615 only)
1. Locate the wiring diagram label included with the
adapter kit. Peel the protective backing off and place it
over the existing label on the CABP3 blower as shown.
2. Locate the foam tape supplied with the downdraft vent.
Place the blower on the floor in the orientation it will be
mounted on the front of the downdraft vent. Peel the
backing off the included foam tape and attach it to the
right and left flanges of the blower base plate.
3. With the exhaust in the desired orientation, slide the
bottom flange of the CABP3 blower base plate behind
the tab on the bottom of the adapter mounted to the
front of the downdraft vent.
4. Cover the opening on the adapter by pushing the
blower against it. Make sure that the foam tape cre-
ates a good seal on the right and left side of the open-
ing. Center the blower base plate horizontally over the
opening on the front of the adapter.
5. Install the adapter top retainer bracket over the blower
base plate flange. Secure it in place with the three (3)
wing nuts, lock washers and flat washers included with
the adapter.
CABP3
Top retainer
bracket
Insert bottom flange into
tab at bottom of adapter
Attach foam
to right/left
flanges
Adapter
New label
Existing
label
ILHSF or REMP Series Blower Installation
If using a ILHSF or REMP series blower, install it according
to the blower installation instructions.
Duct Work Installation
WARNING
Tape all duct joints securely to prevent combustion
by-products, smoke or odors from entering the home.
Doing so will also improve system efficiency.
Install the duct work according to the
Installation
Specifications
section. Use sheet metal screws and duct
tape to connect and seal all of the pieces. Support the duct
weight as necessary to ensure sealed joints.
Electrical Installation
WARNING
•
ELECtRIC SHOCK HAZARD
- Do not connect the
downdraft vent power plug to the electrical outlet until
installation is complete.
• Failure to complete electrical connections properly
may result in an electric shock hazard or a damaged
or non-functional system. Follow the wiring diagrams
carefully to ensure a proper installation. Do not
change the factory wired terminal connections inside
the electrical access panel for the downdraft vent or
the blower.
• To avoid an electric shock hazard and to prevent dam-
age route all wiring away from hot surfaces.
1. For ILHSF and REMP blower installations, run the wir-
ing/conduit line used to supply power from the down-
draft vent to the blower parallel to the duct work.
2. Remove the cover from the downdraft vent electrical
access panel.
3. Connect the wiring/conduit to the blower as shown in
the wiring diagrams below and the facing page accord-
ing to local codes and ordinances. Make sure all ter-
minal connections, including the factory wired connec-
tions, are tight. Replace the electrical access panel.
Range/Cooktop Installation
Install the range or cooktop according to its installation
instructions.