Installation Instructions

Cabinet Blower Installation:

(optional, ERV3015 and ERV3615 only)

1.  Locate the wiring diagram label included with the 

adapter kit. Peel the protective backing off and place it 

over the existing label on the CABP3 blower as shown.

2.  Locate the foam tape supplied with the downdraft vent. 

Place the blower on the floor in the orientation it will be 

mounted on the front of the downdraft vent. Peel the 

backing off the included foam tape and attach it to the 

right and left flanges of the blower base plate.

3.  With the exhaust in the desired orientation, slide the 

bottom flange of the CABP3 blower base plate behind 

the tab on the bottom of the adapter mounted to the 

front of the downdraft vent.

4.  Cover the opening on the adapter by pushing the 

blower against it. Make sure that the foam tape cre-

ates a good seal on the right and left side of the open-

ing. Center the blower base plate horizontally over the 

opening on the front of the adapter. 

5.  Install the adapter top retainer bracket over the blower 

base plate flange. Secure it in place with the three (3) 

wing nuts, lock washers and flat washers included with 

the adapter.

CABP3

Top retainer 

bracket

Insert bottom flange into 

tab at bottom of adapter 

Attach foam

to right/left

flanges

Adapter

New label

Existing 

label

ILHSF or REMP Series Blower Installation

If using a ILHSF or REMP series blower, install it according 

to the blower installation instructions.

Duct Work Installation

 WARNING

Tape all duct joints securely to prevent combustion 

by-products, smoke or odors from entering the home. 

Doing so will also improve system efficiency.

Install the duct work according to the 

Installation 

Specifications

 section. Use sheet metal screws and duct 

tape to connect and seal all of the pieces. Support the duct 

weight as necessary to ensure sealed joints.

Electrical Installation

 WARNING

• 

ELECtRIC SHOCK HAZARD

 - Do not connect the 

downdraft vent power plug to the electrical outlet until 

installation is complete.

•  Failure to complete electrical connections properly 

may result in an electric shock hazard or a damaged 

or non-functional system. Follow the wiring diagrams 

carefully to ensure a proper installation. Do not 

change the factory wired terminal connections inside 

the electrical access panel for the downdraft vent or 

the blower.

•  To avoid an electric shock hazard and to prevent dam-

age route all wiring away from hot surfaces.

1.  For ILHSF and REMP blower installations, run the wir-

ing/conduit line used to supply power from the down-

draft vent to the blower parallel to the duct work.

2.  Remove the cover from the downdraft vent electrical 

access panel. 

3.  Connect the wiring/conduit to the blower as shown in  

the wiring diagrams below and the facing page accord-

ing to local codes and ordinances. Make sure all ter-

minal connections, including the factory wired connec-

tions, are tight. Replace the electrical access panel.

Range/Cooktop Installation

Install the range or cooktop according to its installation 

instructions. 

Summary of Contents for ERV3015

Page 1: ...RV46 Part No 107736 Rev B Use these downdraft vents only with approved Dacor appliances See the installation instructions for the particular appliance model being installed to determine suitability Includes installation instructions for cabinet blower Dacor model CABP3 which is an option for models ERV3015 and ERV3615 ...

Page 2: ...Service Team For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line Whenever you call have the model and serial number of the appliance ready The model and seri al number are printed on the product data label on the front of the unit The product data label also specifies the power sup ply requirements Dacor Customer Service Phone 800 793 0093 ex 2813 U S A and Canad...

Page 3: ...rom the power cord Use an adapter plug Use an extension cord Use a power cord that is frayed or damaged Use of a ground fault interrupter GFI is not recommended DANGER IMPORTANT Do not store or use combustible flammable or explosive vapors and liquids such as gasoline inside or in the vicinity of this or any other appliance Also keep items that could explode such as aerosol cans away from the rang...

Page 4: ... not tamper with the controls Never allow the filters or vent openings to become blocked or clogged Do not allow foreign objects such as cigarettes or napkins to be sucked into the vent holes Clean the filters and all grease laden surfaces often to prevent grease fires and maintain performance Clean this appliance only as specified in the use and care manual Do not leave children or pets alone or ...

Page 5: ... 1 4 94 6 cm Adjustable anchor legs Product data label Tolerances 1 16 1 6 mm unless otherwise stated Model Number A Top Cap Width B Chassis Width ERV3015 30 76 2 cm 27 3 8 69 5 cm ERV3615 36 91 4 cm 33 3 8 84 8 cm See pages 9 and 10 for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum specified counter height for cooking appliance See installation instruct...

Page 6: ... mm Top cap with vent down Tolerances 1 16 1 6 mm unless otherwise stated Model Number A Top Cap Width B Chassis Width ERV48 48 121 9 cm 43 3 8 110 2 cm PRV30 30 76 2 cm 27 3 8 69 5 cm PRV36 36 91 4 cm 33 3 8 84 8 cm PRV46 46 116 8 cm 43 3 8 110 2 cm See page 9 for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum specified counter height for cooking applian...

Page 7: ...unit 6 15 2 cm 2 9 16 6 5 cm 2 1 2 6 4 cm 1 15 16 4 9 cm B A Adjustable anchor legs 2 13 16 7 1 cm 1 4 6 mm Top cap with vent down Tolerances 1 16 1 6 mm unless otherwise stated Model Number Top Cap Width A Chassis Width B ERV36 ER 36 91 4 cm 33 3 8 84 8 cm ERV48 ER 48 121 9 cm 43 3 8 110 2 cm See page 9 for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum ...

Page 8: ...ion and service Any drawers or shelves must be easy to remove for access to the cooktop downdraft vent and utilities There are 7 8 access holes in the bottom and side of the downdraft vent for connecting the blower wiring and strain relief Wire the blower to turn on when the down draft vent is turned on When installing a remote or in line blower run the blower wiring conduit parallel to the duct w...

Page 9: ... conduit from downdraft to remote blower Cabinet blower option on ERV3015 and ERV3615 only Cooktop Floor 12 min 30 5 cm 3 1 4 x 10 90 elbow Wall Downdraft vent Wall cap Backsplash ILHSF series in line blower 3 x 10 to round transition Duct work Duct work Outside wall Range Wall cap on outside wall Downdraft vent Downdraft vent configured for bottom exhaust Floor Wiring conduit from downdraft to in...

Page 10: ...y require the use of makeup air systems with ventilation systems that move air greater than the specified movement rate CFM The specified rate var ies based on locale Consult a qualified HVAC specialist when designing the system for the requirements in your area and to assure optimal performance You must install one of the Dacor blower models listed below for the downdraft vent to operate properly...

Page 11: ...knock out lines up with vertical center line of chassis On 30 and 36 wide models the vertical center line of bottom knock out is offset 3 Side Exhaust Knock Outs 1 5 8 x 16 Bottom Exhaust Knock Out 1 5 8 x 16 Motor cover Front of unit 26 66 0 cm 6 1 4 15 9 cm 1 1 8 2 9 cm C L C L C L Exhaust Knock out Locations for Use with REMP and ILHSF Series Blowers Use sheet metal screws as required to suppor...

Page 12: ... Countertop 3 1 4 x 10 duct connection Duct connection center line B Downdraft vent center line Countertop 3 1 4 x 10 duct connection 15 3 8 39 1 cm Duct connection center line A Downdraft vent center line Countertop 3 1 4 x 10 duct connection 26 1 4 66 7 cm Exhaust Locations and Side Dimensions for CABP3 Cabinet blower Exhaust Locations and Dimensions for CABP3 Cabinet Blower Installations ERV301...

Page 13: ...t 2 feet 36 feet The maximum amount of straight duct that can be used with a REMP16 and the above components is 60 feet 34 feet 24 feet Equivalent Number of Feet Nominal Duct Elbows and Transitions 45 elbow 8 inch 3 feet 3 x 10 45 elbow 7 feet 45 elbow 10 inch 2 feet 3 x 10 90 elbow 15 feet 90 elbow 8 inch 7 feet 3 x 10 90 flat elbow 20 feet 90 elbow 10 inch 5 feet 3 x 10 to 8 round transition 4 f...

Page 14: ... cut out separate from the range or cooktop Install the down draft vent before installing the range or cooktop 2 Start by loosely attaching the anchoring legs to the studs on the left and right sides of the downdraft vent using the provided Keps nuts and washers Installation Preparation for Downdraft Vent with ILHSF or REMP Series Blower NOTE For units using the CABP3 cabinet blower skip to Instal...

Page 15: ...he three 3 wing nuts and three 3 flat washers on the front of the unit Discard the three 3 lock wash ers they will be replaced Tilt the cover out and pull up to remove it 2 Peel the backing off of some of the foam tape included with the adapter Attach it to the right and left flanges 3 Hold the adapter in front of the opening on the front of the unit with the adapter s studs on top and all the fla...

Page 16: ... the blower installation instructions Duct Work Installation warning Tape all duct joints securely to prevent combustion by products smoke or odors from entering the home Doing so will also improve system efficiency Install the duct work according to the Installation Specifications section Use sheet metal screws and duct tape to connect and seal all of the pieces Support the duct weight as necessa...

Page 17: ...ical Installation CABP3 Cabinet Blower Downdraft Vent Electrical Access Panel Front of unit Wire Colors Black Line L White Neutral N Green Ground Gnd Electrical connection from downdraft vent match Wire Colors CABP3 cabinet blower Downdraft vent blower wiring access hole Ground Power Input Blower Output Blower power wiring conduit Connect other end of wires to blower terminal block Wires to power ...

Page 18: ...hat power is being supplied to the unit Make sure that power is being supplied to the blower from the downdraft vent If the vent will not raise properly or makes a scraping sound check for obstructions interfering with the raising of the unit If the downdraft vent still does not function after perform ing the above checks do not attempt to repair it yourself Contact Dacor Distinctive Service at 79...

Page 19: ...BLK WHT WHT Wiring Diagram All Models CABP3 Cabinet Blower Ratings CABP3 Cabinet blower Airflow Nominal 600 CFM Actual 585 6 CFM At zero inches static pressure Performance varies based on duct system configuration Electrical Rating 4 Amps 120 Vac 60 Hz For ILHSF or REMP series blower ratings see the blower installation instructions Airflow CFM Cubic feet minute Static pressure inches of water 0 1 ...

Page 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Reviews: