PLANNING
GUIDE
COMBINATION INSTALLATIONS
RGC/SGM Series Drop-In Gas Cooktop
with ERV/PRV Series Raised Vent
Document # PGCI-008
Revised 10/04/12 Page 1/2
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space
behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
SGM series cooktop
warning
•
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
•
All appliances must be installed in accordance with the
accompanying installation instructions.
All tole1/16” (+1.6 mm), -0, unless otherwise noted.
Cutout Dimensions
SIDE VIEw - RGC/SGM SERIES COOkTOP wITh
ERV/PRV SERIES RAISED VENT
iMPOrTanT:
Be careful to use the correct cutout diagram (on page 2/2) to determine the countertop dimensions. Carefully double check all dimensions
against the table below and the correct diagram before cutting the countertop.
* Total cutout depth, accommodates both the cooktop and raised vent
**
iMPOrTanT:
Notch depth is included in total cutout depth (D).
DO nOT
add notch depth to total cutout depth (D).
RGC or SGM series cooktop
Countertop Dimensions
installation Type
Cutout
Diagram
C (minimum)
D
E
F
g
H
RGC/SGM304 with
ERV30[15] or PRV30
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
RGC/SGM365 with
ERV36[15] or PRV36
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
RGC/SGM466 with
PRV46
Figure 2
(Notched)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)