background image

4

Cabinet and Countertop Layout

 WARNING

To avoid the risk of fire or personal injury, all minimum  

and maximum specified clearances on this and the 

following pages must be maintained or exceeded.

General Considerations

The minimum distance from the back of the cooktop 

• 

to a combustible rear wall is 2 1/2” (64 mm) minimum 

(Figure 1).
Installation of a non-combustible material* (up to the 

• 

hood) or a backsplash is always recommended, and 

mandatory if the distance to the back wall from the 

cooktop is less than 2 1/2” (Figure 2). When installing a 

backguard, use only Dacor model numbers AEB3609, 

AEB3612 (ESG366), AEB4809 or AEB4812 (ESG486).
* Consult local codes and ordinances for acceptable 

non-combustible materials.

Carefully check the location where the cooktop is to be 

• 

installed. For best performance, the cooktop should be 

installed away from drafts caused by doors, windows 

and heating and air conditioning outlets. To reduce the 

risk of personal injury from reaching over a hot appli-

ance, avoid cabinet installations directly above.
To reduce the risk of personal injury and to reduce 

• 

accumulated smoke in the room, Dacor strongly recom-

mends installing a range hood. A hood should project 

horizontally a minimum of five (5) inches beyond the 

face of the cabinets.

Installation Requirements

The installation must allow access to the underside 

• 

of the cooktop for service and inspection purposes, 

including the ability to turn off the cooktop gas supply 

valve and electrical outlet.
All contact surfaces between the cooktop and the coun-

• 

ter must be solid and level.
The countertop overhang on the sides of the cutout 

• 

shown on the following pages covers the recessed por-

tions of the cooktop behind the control panel and cre-

ates a seamless look for the installation.

IMPORTANT: 

• 

When installing the cooktop into a lami-

nated or synthetic countertop, radius the corners of the 

cutout to help avoid cracking. Consult the countertop 

manufacturer’s instructions for minimum corner radius, 

reinforcement and heat protection requirements.
For installations with a raised vent, install this appliance 

• 

only with the approved Dacor raised vent models listed 

on page 6.

Gas and Electric Service Location

The gas supply piping, gas shut-off valve and the elec-

• 

trical outlet must be located so they do not interfere 

with the cooktop when it is installed. If installing another 

appliance in the cabinet below, allow for the routing of 

gas and electrical service out the back of the unit.
The shaded area on the facing page shows the rec-

• 

ommended location of the gas inlet and the electrical 

outlet. For replacement purposes, the location of the 

existing utilities may be utilized provided they do not 

interfere with the sides or rear of the cooktop. Check 

local building codes for permissible utility locations.
For best performance and to minimize gas pressure 

• 

loss, attach the gas supply regulator as close as pos-

sible to the cooktop gas inlet.

The installation must:

Allow for access to the gas shut-off valve and regulator 

• 

when the unit is installed.
Allow for access to the electrical outlet, when the 

• 

cooktop is in place so that the power cord may be eas-

ily disconnected if the unit needs service.
Allow for the (36”) power cord reaching the electrical 

• 

outlet.
If a raised vent is to be installed, allow for access to the 

• 

gas supply valve and electrical outlet when the raised 

vent is in place.

Combustible

rear wall

Backguard mandatory if

gap from back of cooktop

to combustible wall is less

than 2 1/2”

Combustible

rear wall

2 1/2” (64 mm) Min. to

combustible rear wall

FIGURE 1

FIGURE 2

Summary of Contents for Epicure ESG366SBK

Page 1: ...Installation Instructions Epicure Cooktop Models ESG366 ESG486 Part No 65162 Rev K...

Page 2: ...d the local building inspector s use 2007 Dacor all rights reserved If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team Fo...

Page 3: ...ANT If you smell gas Do not use or light any appliance Do not touch any electrical switch or use any electrical devices including the telephone in your building From a neighbor s phone immediately cal...

Page 4: ...ure accompa nying it This cooktop is not intended for commercial or laboratory use DO NOT TOUCH THE SURFACES OF THE COOKTOP OR THE SURROUNDING AREAS DURING OR IMMEDIATELY AFTER USE WARNING General Saf...

Page 5: ...led in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 The gas service must be installed by a qualified profes sional Be certain that the cooktop being installed is correct for the gas...

Page 6: ...behind the control panel and cre ates a seamless look for the installation IMPORTANT When installing the cooktop into a lami nated or synthetic countertop radius the corners of the cutout to help avo...

Page 7: ...1 16 0 1 6 mm 0 unless otherwise noted Cooktop Model B C ESG366 36 914 mm 36 914mm 42 1067 mm ESG486 48 1219 mm 48 1219 mm 54 1372 mm Minimum Recommended Continued on following pages See note 2 2 See...

Page 8: ...ing platform 8 W X 6 D 203 mm X 152 mm if gas and electrical are routed through bottom 1 2 13 mm countertop overhang 1 thick mounting platform Min Countertop Countertop 1 2 13 mm countertop overhang 2...

Page 9: ...Open to below to allow for raised vent gas and electrical connections Countertop Countertop 1 2 13 mm countertop overhang 2 51 mm 1 25 mm 11 7 16 291 mm 15 381 mm 24 5 8 625 mm C L D D E B C L C L C L...

Page 10: ...ure kit WOK ring Griddle Simmer plate Spatula Model ESG486 comes with 3 14 inch grates Model ESG366 comes with 2 10 inch grates and 1 14 inch grate Cooktop Installation WARNING To prevent damage to th...

Page 11: ...e regulator included with the 1 cooktop to the gas inlet on the cooktop The inlet is located on the bottom at the right rear portion of the chassis For tight installations the regulator may be install...

Page 12: ...Once the burner lights the control knob can be rotat ed counterclockwise from HIGH to LOW to adjust the flame height progressively When the unit is installed properly the flame will be steady It will...

Page 13: ...ice for the cooktop located and installed according to these instructions and in accordance with all applicable codes See pages 3 and 4 Has the gas supply inlet pressure been measured to ensure that i...

Page 14: ...12 Wiring Diagram...

Page 15: ......

Page 16: ...Dacor Phone 800 793 0093 FAX 626 403 3130 www Dacor com...