3
NOTES:
1. Minimum hood clearances are
zero inches (0”) to the rear,
sides and top of the hood.
2. Thirty inches (30”) is the
minimum distance between
the bottom of the hood and
any cooking surface.
3. Maximum effective clearance
from cooking surface to
bottom of hood is 36”
(914mm).
wARNINGS:
1. CAUTION: To reduce the
risk of fire and to properly
exhaust air, be sure to duct air
outside. Do not vent exhaust
air into spaces within walls or
ceilings, or into attics, crawl
spaces or garages.
2. Tape all duct joints securely
to prevent combustion
by-products, smoke or odors
from entering the home. This
will also improve the efficiency
of the system.
3. Do not exhaust more than one
vent into a single duct run.
4. Only use duct work
constructed of materials
deemed acceptable by state,
municipal and local codes.
Cabinet Preparation
Electrical Access hole Locations
1 1/2"
(38mm)
7/8"ø (11mm) Holes
A
B
C
L
C
L
C
L
CL
Rear of hood
Vertical Electrical Access hole Locations, Top View
C
L
3/4"
(19mm)
7/8"ø (11mm) Holes
Top of hood
C
D
C
L
C
L
CL
horizontal Electrical Access hole Locations, Rear View
Model
A
B
C
D
EHD3009
EHDR3009
MHD3009
9” (229mm)
1 ½”
(38mm)
9” (229mm)
1 ½”
(38mm)
EHD3609
EHDR3609
MHD3609
9 ½”
(241mm)
2”
(51mm)
8” (203mm)
1 ½”
(38mm)
EHD4209
EHDR4209 14” (356mm)
1 ½”
(38mm)
14”
(356mm)
1 ½”
(38mm)
EHD4809
EHDR4809
MHD4809
16 ½””
(419mm)
1 ½”
(38mm)
16 ½””
(419mm)
1 ½”
(38mm)
EHD3018
EHDR3018
MHD3018
9” (229mm)
1 ½”
(38mm)
9” (229mm)
1 ½”
(38mm)
EHD3618
EHDR3618
MHD3618
9 ½”
(241mm)
2”
(51mm)
8” (203mm)
3 ½”
(89mm)
EHD4218
EHDR4218
14 7/16”
(367mm)
1 ½”
(38mm)
14 7/16”
(367mm)
1 ½”
(38mm)
EHD4818
EHDR4818
MHD4818
14 7/16”
(367mm)
1 ½”
(38mm)
16 15/16”
(430mm)
1 ½”
(38mm)
EHD5418
EHDR5418
14 7/16”
(367mm)
4 ½”
(114mm)
14 7/16”
(367mm)
4 ½”
(114mm)
30" (762mm) Minimum
from cooktop surface to bottom of hood
"A"
hood
width
A - Cutout width
30”
30” (762mm)
36”
36” (915mm)
42”
42” (1067mm)
48”
48” (1219mm)
54”
54” (1372mm)
Cabinet Planning
wARNING:
Failure to provide proper
minimum clearance may result in
a fire or safety hazard.
Duct Planning