2
Model No.
(A) width
(B) Depth
EHD3009
EHDR3009
29 7/8”
(759mm)
24” (610mm)
EHD3609
EHDR3609
35 7/8”
(911mm)
EHD4209
EHDR4209
41 7/8”
(1064mm)
EHD4809
EHDR4809
47 7/8”
(1216mm)
MHD3009
29 7/8”
(759mm)
22 1/2”
(571mm)
MHD3609
35 7/8”
(911mm)
MHD4809
47 7/8”
(1216mm)
11 7/8"
(302mm)
"A"
9
(229mm)
"B"
Verifying the Package Contents
• Use and care manual
• Filters
• Light bulbs, halogen 75W
• Suction cup
Installation Planning
A qualified technician must complete the
installation of this built-in appliance. Proper
installation is your responsibility.
Carefully check the location where the
hood is to be installed. The hood should be
placed for convenient access. Make certain
that electrical power can be provided in the
selected location.
Plan the installation so that all minimum
clearances are met or exceeded. Dimen-
sions shown provide minimum clearances,
unless otherwise noted.
The specified minimum cabinet depth and
width must be provided.
Cabinet cutout dimensions must be used
as indicated. All contact surfaces between
the appliance and the cabinet must be solid
and level.
Make certain that you have everything
necessary to ensure a proper installation
before proceeding.
NOTE:
All tole 1/16”, - 0” unless
otherwise stated.
Overall Dimensions
Overall Dimensions
(MhD Series Shown)
9” high hood Overall Dimensions
11 7/8"
(302mm)
"A"
18
(457mm)
"B"
Overall Dimensions
(MhD Series Shown)
18” high hood Overall Dimensions
Model No.
(A) width
(B) Depth
EHD3018
EHDR3018
29 7/8”
(759mm)
26 7/8”
(683mm)
EHD3618
EHDR3618
35 7/8”
(911mm)
EHD4218
EHDR4218
41 7/8”
(1064mm)
EHD4818
EHDR4818
47 7/8”
(1216mm)
EHD5418
EHDR5418
53 7/8”
(1368mm)
MHD3018
29 7/8”
(759mm)
25 1/2”
(648mm)
MHD3618
35 7/8”
(911mm)
MHD4818
47 7/8”
(1216mm)
6 1/8"
(156mm)
8" (203mm)
Round Duct
Collar
C
L
CL
Vertical Exhaust Duct Location
3009, 3609, 3018, 3618 Configurations
Top View
(EhD Series Shown)
6 1/8"
(156mm)
10" (254mm)
Round Duct
Collar
C
L
C
L
Vertical Exhaust Duct Location
4218, 4818, 5418 Configurations
Top View
(EhD Series Shown)
6 1/8"
(156mm)
8" (203mm)
Round Duct
Collars
C
L
6 ½"
(165mm)
6 ½"
(165mm)
C
L
CL
C
L
Vertical Exhaust Duct Location
4209, 4809 Configurations
Top View
(EhD Series Shown)
Exhaust Duct Locations
4"
(102mm)
3 1/4" x 10"
(83x254mm)
Duct
C
L
C
L
horizontal Exhaust Duct Location
3018, 3618 Configurations
Rear View
(EhD Series Shown)
4"
(102mm)
3 1/4" x 10"
(83x254mm)
Ducts
CL
6"
(152mm)
6"
(152mm)
C
L
C
L
C
L
horizontal Exhaust Duct Location
4218, 4818, 5418 Configurations
Rear View
(EhD Series Shown)
21"
(533mm)
8"
(203mm)
12"
(305mm)
10" Round
ADT10 Custom Transition
For 4209, 4809 Configurations