PLANNING
GUIDE
10.1
Specifications subject to change without notice.
Phone: (800) 793-0093
www.Dacor.com
DDWF24S
24” Wide Built-In Dishwasher
Front
24” (61.0 cm)
34 3/8”
(87.4 cm)
to
36 1/2”
(92.7 cm)
Drain hose
23 3/4” (60.3 cm)*
2” (50.0 cm)
5 1/4” (13.5 cm) to
7 1/4” (18.5 cm)
Depth with door closed
Depth dimensions allow
for hose on back of unit
49 3/4” (126.4 cm)
Depth with door open
* 23 1/2” (59.7 cm) to front panel trim edge
Side
3 1/4" (8.3 cm)
2 3/4" (7.0 cm)
Back
Do not modify
loop in hose
54” (137.0 cm)
long
Drain hose
44” (112.0 cm)
long
Power cord
Water supply line
60” (152.0 cm)
long
Product Dimensions
Electrical Specifications
Dedicated Circuit Required
Total
Connected Load
Grounded, 3-prong, electrical outlet
supplied by 120 Vac,
60 Hz, 15 Amp. (circuit breaker)
11 Amp. @ 120 Vac, 60 Hz.
■
The above specifications are for reference only. For exact
specifications see the product data label, located inside the right door
jamb.
■
Do not modify the power cord or use an extension cord. The power
cord may be disconnected from the appliance and hard-wired to a
junction box connected to a circuit meeting the above specifications if
the power cord is not long enough.
Water Supply Specifications
■
Water Pressure:
4.2 to 125 p.s.i. (30-862 kPa) with minimum water
flow of 3 gallons (12 liters) per minute.
■
Water Supply Temperature:
Cold or hot water supply (max. 140°F,
60°C) may be used. Dacor recommends a hot water supply of 120°F
(49°C) to 140°F (60°C). If a cold water supply is used, washing times
will be longer but performance will not be affected.
■
Water Supply Valve Requirement:
3/8” water supply valve for
connection to dishwasher’s water supply line is required in a location
where it is easily accessible after the dishwasher is installed. The
dishwasher water supply line is equipped with a 3/8” (1.0 cm) NPT
female compression fitting on the end.
Product tolerances: ±1/16” (±1.6 mm) otherwise stated
Document # PG10-004
Revised 02/03/11 Page 1/3
WaRning
•
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
•
This appliance must be installed in accordance with the
accompanying installation instructions.
UtILIty CoNNECtIoN DImENSIoNS
approximate
Shipping Weight
108 lbs. (49 kg.)