background image

PLANNING

GUIDE

10.1

Specifications subject to change without notice.

Phone: (800) 793-0093

www.Dacor.com

DDWF24S

24” Wide Built-In Dishwasher

Front

24” (61.0 cm)

 

34 3/8” 

(87.4 cm)

to

36 1/2” 

(92.7 cm)

Drain hose

23 3/4” (60.3 cm)*

2” (50.0 cm)

5 1/4” (13.5 cm) to

7 1/4” (18.5 cm)

Depth with door closed

Depth dimensions allow 

for hose on back of unit

49 3/4” (126.4 cm)

Depth with door open

* 23 1/2” (59.7 cm) to front panel trim edge

Side

3 1/4" (8.3 cm)

2 3/4" (7.0 cm)

Back

Do not modify

loop in hose

54” (137.0 cm) 

long

Drain hose

44” (112.0 cm) 

long

Power cord

Water supply line

60” (152.0 cm) 

long

Product Dimensions

Electrical Specifications

Dedicated Circuit Required

Total 

Connected Load

Grounded, 3-prong, electrical outlet  

supplied by 120 Vac,  

60 Hz, 15 Amp. (circuit breaker)

11 Amp. @ 120 Vac, 60 Hz. 

 

The above specifications are for reference only. For exact 

specifications see the product data label, located inside the right door 

jamb.

 

Do not modify the power cord or use an extension cord. The power 

cord may be disconnected from the appliance and hard-wired to a 

junction box connected to a circuit meeting the above specifications if 

the power cord is not long enough.

Water Supply Specifications

 

Water Pressure:

 4.2 to 125 p.s.i. (30-862 kPa) with minimum water 

flow of 3 gallons (12 liters) per minute.

 

Water Supply Temperature:

 Cold or hot water supply (max. 140°F, 

60°C) may be used. Dacor recommends a hot water supply of 120°F 

(49°C) to 140°F (60°C). If a cold water supply is used, washing times 

will be longer but performance will not be affected.

 

Water Supply Valve Requirement:

 3/8” water supply valve for 

connection to dishwasher’s water supply line is required in a location 

where it is easily accessible after the dishwasher is installed. The 

dishwasher water supply line is equipped with a 3/8” (1.0 cm) NPT 

female compression fitting on the end.

Product tolerances: ±1/16” (±1.6 mm) otherwise stated

Document # PG10-004

Revised 02/03/11   Page 1/3

 WaRning

• 

Observe all governing codes and ordinances during planning 

and installation. Contact your local building department for 

further information. 

• 

This appliance must be installed in accordance with the 

accompanying installation instructions.

UtILIty CoNNECtIoN DImENSIoNS

approximate

Shipping Weight

108 lbs. (49 kg.)

Reviews: