background image

PLANNING

GUIDE

10.3

Specifications subject to change without notice.

Phone: (800) 793-0093

www.Dacor.com

DDWF24S

24” Wide Built-In Dishwasher

ExAmPLE oF DrAIN CoNNECtIoN WIthoUt AIr GAP

ExAmPLE oF DrAIN CoNNECtIoN WIth AIr GAP

Document # PG10-004

Revised 02/03/11   Page 3/3

Drain Specifications

 

The drain connection must be a minimum of 20" (50.8 cm) above 

the floor. No part of the drain hose can be lower than the disposer or 

waste tee connection or higher than 37 1/2” (95.0 cm) above the floor.

 

Should a drain hose longer than the one provided be required, use a 

hose extension approved for detergents and high temperature water.

 

Total drain hose length (including any extensions) must not exceed 

14 ft. 9 in. (450.0 cm) in length from the top of the drain loop on the 

back of the unit. Joints and joint tubes must have a minimum inside 

diameter of 5/8” (1.6 cm).

 

The drain hose supplied with the dishwasher must be connected 

to a minimum 1/2" inside diameter drain connection. A clamp is not 

supplied. The drain hose is equipped with a connector that fits drain 

connections with an internal diameter of 1/2" to 7/8" (1.3 to  

2.2 cm).

 

Install an air gap in the drain system if required by local codes. 

Plan the air gap location on the countertop area adjacent to the 

dishwasher. A section of drain hose (not provided) needs to be 

installed from the air gap to the drain connection.

 

If an air gap is not required, the drain hose must be installed to a 

disposer inlet or waste tee above the drain trap in the household 

plumbing.

20" 

min.

20" 

min.

Sink trap

Sink trap

Floor

Floor

Drain 

connection

Drain connection

Keep drain hose 

higher than drain 

connection

Keep drain hose 

higher than drain 

connection