PLANNING
GUIDE
10.3
Specifications subject to change without notice.
Phone: (800) 793-0093
www.Dacor.com
DDWF24S
24” Wide Built-In Dishwasher
ExAmPLE oF DrAIN CoNNECtIoN WIthoUt AIr GAP
ExAmPLE oF DrAIN CoNNECtIoN WIth AIr GAP
Document # PG10-004
Revised 02/03/11 Page 3/3
Drain Specifications
■
The drain connection must be a minimum of 20" (50.8 cm) above
the floor. No part of the drain hose can be lower than the disposer or
waste tee connection or higher than 37 1/2” (95.0 cm) above the floor.
■
Should a drain hose longer than the one provided be required, use a
hose extension approved for detergents and high temperature water.
■
Total drain hose length (including any extensions) must not exceed
14 ft. 9 in. (450.0 cm) in length from the top of the drain loop on the
back of the unit. Joints and joint tubes must have a minimum inside
diameter of 5/8” (1.6 cm).
■
The drain hose supplied with the dishwasher must be connected
to a minimum 1/2" inside diameter drain connection. A clamp is not
supplied. The drain hose is equipped with a connector that fits drain
connections with an internal diameter of 1/2" to 7/8" (1.3 to
2.2 cm).
■
Install an air gap in the drain system if required by local codes.
Plan the air gap location on the countertop area adjacent to the
dishwasher. A section of drain hose (not provided) needs to be
installed from the air gap to the drain connection.
■
If an air gap is not required, the drain hose must be installed to a
disposer inlet or waste tee above the drain trap in the household
plumbing.
20"
min.
20"
min.
Sink trap
Sink trap
Floor
Floor
Drain
connection
Drain connection
Keep drain hose
higher than drain
connection
Keep drain hose
higher than drain
connection