Setting-up sole plate
Adjust the sole plate so that there is a regular distance between
ceramic ferrule and stud. Otherwise the stud is hindered when
dipping into the melting.
— Slightly loosen screws connecting sole plate and pillars.
— Shift sole plate until there is a regular distance between
stud and ceramic ferrule.
— Tighten screws and check distance once again.
— Also check the stud protrusion. If necessary adjust again.
Only when using ceramic ferrules:
Setting-up sole plate
Adjust the sole plate so that there is a regular distance between
ceramic ferrule and stud (centre). Otherwise the stud is hinde-
red when dipping into the melting.
— Slightly loosen screws connecting sole plate and pillars.
— Shift sole plate until there is a regular distance between
protection pipe and stud.
— Tighten screws and check distance once again.
— Also check the stud protrusion. If necessary adjust again.
Ceramic
ferrule
Ceramic
ferrule holder
Regular distance between
stud and ceramic ferrule
Sole plate
Stud
Screw
Stud protection
pipe
Regular distance be-
tween stud and protecti-
on pipe
Sole plate
Stud
Screw
Setting-up equipment and welding gun
19