28

Burning mode, Level 2 

(below 100%) [-1.5%]-98.5%

17

Heat-Fan   1

Burn Fan 1

Operating cycle of the fan in 
Burning mode, Level 1 

(below 100%) [-1.5%]-98.5%

18

StopMaxTime

Stop Max Time

Duration of mode OFF[7’00]-
7minutes

19

StopFlame

Stop Flame

Flame in mode OFF,(below 
value)[7.0%]-70

20

Pump T

Pump T

Temperature limit for 
activating the pump

Above T[40ºC]

21

MaxPWR

Max Level

Maximum operating  level of 
the burner        1 to 3

22

Par22

System 

System parameter. Do not 
change.

23

Mode

Mode

System parameter. Do not 
change.

24

Heat-AutoClean

Auto clean

Time period during Burn mode 
for activation of Automatic 
cleaning (if available)

25

Code

Code!

Access code

26

T-Corr

T-Cor

Correction of the temperature 
controller with +/- 5ºC (Do not 
change!)

27

dT Max->Min

dT power 
regulation

Temperature  difference for the 
regulation of maximum to 
minimum value.

28

AMB Pause

AMB_DELAY

Delay in Ambient thermostat 
action. 

(set to 0 will deactivate this 

feature)

Summary of Contents for Prity

Page 1: ...Pellet Burner PRITY Instructions for installation adjustment and operation...

Page 2: ...he combustion process Modulation of thermal output according water temperature Input for room thermostat Input for tele control GSM Real time clock with two on off timers Automatic restart Automatic c...

Page 3: ...per hour Table of contents 1 Principle diagram 2 Safety rules 3 Instructions for installation commissioning and safe operation 4 Service technician guide The Pellet Burner PRITY is produced in full c...

Page 4: ...1 Control panel 2 Pellet inlet 3 Flange connector 4 Combustion chamber 5 Feeder cable 6 Auger plug 7 Temperature controller 8 On Off 9 Fuse 10 Auger transporter 11 Gear screw 12 Feeder cable 13 Stand...

Page 5: ...embly safe distance of at least 200 mm must be respected if not place rock wool insulation of the wall and the cladding This distance applies to fireplaces and flue located near material with a B and...

Page 6: ...omer A sensor for temperature higher than 90 95 C is placed on the feeding tube of the burner If during operation the temperature sensor detects a temperature higher than 90 95 C the auger stops and t...

Page 7: ...ter connecting the burner to the boiler the technician should connect it to the control panel and then to the electrical network Attention The connection must be done by a qualified electrical technic...

Page 8: ...at 100 The auger gets pellets from the bottom inlet and starts to transport them to the top output After the preset from the manufacturer time elapses providing feeding with a dose of pellets for the...

Page 9: ...at low power for certain time according parameter settings GSM Tele control The burner is supplied with tele control input for connection of external GSM tele control module The commands given can sta...

Page 10: ...t requires minimal maintenance The maintenance work directly depends on the quality and the size of the used pellets Removing the ash During the process of wooden pellets burning there remains about 0...

Page 11: ...feeding module ATTENTION SWITCH OFF THE POWER SUPPLY BEFORE OPENING THE COVER The check must be done by a qualified electrical technician check the voltage source check for loose connections check th...

Page 12: ...least 30 seconds 5 If the pellets do not ignite during the preset time Parameter 03 Start Max Time new attempt for ignition will starts but with 1 2 dose of pellets 6 After stable flame is detected th...

Page 13: ...the burner goes into Level 1 5 If the burner exceeds the Tmax or the burner is switched OFF or the preset time interval set by clock timer elapses the device goes into mode Turn off 6 If the detected...

Page 14: ...2 Pellets feeding pause Parameter 12 Burn Auger Pause 2 The fan works at defined speed Parameter 16 Burn Fan2 Operating at Level 3 Pellets feeding pause Parameter 11 Burn Auger Pause 3 The fan works...

Page 15: ...led or GSM tele control off command is issued Automatic start from the clock upon reaching a preset time for turning on the burner starts automatically Automatic stop from the clock upon reaching a pr...

Page 16: ...e is no flame the position is blank p indication of the status of the pump if it is switched on the symbol P is displayed if it is switched off the symbol p is displayed i indication for the ignition...

Page 17: ...ted Stop suspending the operation of the burner and the preset time for ending the cycle Standby the pre set maximum temperature is reached Upon reaching the pre set minimum temperature the burner is...

Page 18: ...ow or digits C delete OK for confirmation ESC for exit from the menu 4 Screen 2 is displayed by pressing the button Timer once Row1 Changing state of the timers Indication for the state of the timers...

Page 19: ...in 15 minutes Edit by pressing the OK button Put before the hour and minutes Change the value by using Dn arrow or Up arrow or digits C delete OK for confirmation ESC for exit from the menu 6 Screen...

Page 20: ...or Up arrow or digits C delete OK for confirmation ESC for exit from the menu Service Menu Access to the service menu is done by pressing the SET button The service menu is arranged in rows 1 to 7 Set...

Page 21: ...l activation of the auger transporter for 10 seconds Edit by pressing the OK button or just press 3 Change the value by using Dn arrow or Up arrow or digits ESC exit from the menu Note This option can...

Page 22: ...g the OK button or just press 6 Change the value by using Dn arrow or Up arrow or digits For factory reset enter 333 and press OK inscription FACTORY should be displayed shortly All vital parameters s...

Page 23: ...een parameter number and parameter value To change between parameters place parameter number YY in by pressing OK button and use Dn Arrow or Up Arrow or digits to navigate To change displayed paramete...

Page 24: ...al start time of the burner 50 C 01 Tmax Tmax Maximum temperature for the burner to stop 70 C 02 StartFeed ON Start Auger Time for initial pellets feeding 35 sec 03 StartMaxTime Start Max time Maximum...

Page 25: ...Feed ON Burn Auger Run Operating cycle of the auger in Burning mode 0 01 0 1 0second 11 Heat FEED Pause3 Burn Auger Pause 3 Operating cycle of the auger in Burning mode Level 3 0 08 8seconds 12 Heat...

Page 26: ...el Maximum operating level of the burner 1 to 3 22 Par22 System System parameter Do not change 23 Mode Mode System parameter Do not change 24 Heat AutoClean Auto clean Time period during Burn mode for...

Page 27: ...s 1 and 2 2 Power supply of the fan for hot flue gases 220V AC terminals 3 and 4 3 Power supply of the gear screw of the auger 220V AC terminals 5 and 6 4 Power supply of the ignition heater relay 220...

Page 28: ...28 WARRANTY REGISTRATION CARD...

Page 29: ...eration of the product only in accordance with requirements for installation and usage in commissioning and service The warranty does not apply for 1 Non compliance conditions for installation and ope...

Reviews: