Precautions and warnings “after” the use of equipment

- Always maintain the equipment clean for the next operation.

- Do not modify any part of the equipment. Do not disconnect the cable or other connections 

without need.

- After using the equipment, clean and disinfect all the parts which may be in contact with the patient.

- If the equipment has any abnormality, check if the problem is related to any item listed in the topic

of unforeseen events (failures, causes and solutions). If it is not possible to resolve the problem, 

contact your representative (Alliage).

Precautions to be adopted against foreseeable or uncommon risks, related to

the deactivation and abandoning of equipment

In order to avoid environmental contamination or undue use of the Equipment after it has become

useless, it should be discarded in the suitable place (as per the local legislation of the country).

- Pay attention to the local legislation of the country for the conditions of installation and disposal

of residue.

- The use of pneumatic or electric tools to perform any type of recording on handpieces, could lead

to damage to the surface treatment of the product, causing the loss of warranty.

Manufacturer shall not be responsible for:

- Use of the equipment differing from that for which it is intended.

- Damages caused to the equipment, the professional and/or the patient by the incorrect installation

and erroneous procedures of maintenance, differing from those described in these Instructions for

use which come with the equipment or by the incorrect operation of it.

Precautions for the Reduction of the Environment Impact

Alliage S/A aims to achieve an environmental policy that encourages the environmentally conscious

supply  of  medical  products  that  continuously  minimize  environmental  impact  and  are  more 

environmentally friendly and human health friendly.

To keep a minimum impact on the environment, observe the following recommendations:

• After installation, forward the recyclable materials for the recycling process.

• During the life circle of the equipment, turn it off when it is not being used.

The biomedical waste comprises nonhigh material susceptible to cause disease or house pathogenic

organisms  that  must  be  stored  in  a  yellow  bag  properly  labeled  with  the  symbol  of  biological 

hazard, or stored in a container resistant to perforation, tight and even collection and incineration.

The packaging consists of cardboard, plastic and expanded polystyrene (EPS) which are

100% recyclable materials.

Dimensions:

Main unit: 0,170 X 0,071 X 0,030 / MASS: About: 0,155 Kg.

Precautions in case of alteration in the functioning of equipment

Warning 

Do not use the equipment in conditions unsuitable for use.

PRECAUTIONS, RESTRICTIONS AND WARNINGS

Summary of Contents for MICROMOTOR INTRA SL 30 TB SI

Page 1: ......

Page 2: ...ROMOTOR INTRA SL 30 TM SI Brand Dabi Atlante Manufacturer Distribuitor Alliage S A Indústrias Médico Odontológica C N P J 55 979 736 0001 45 Insc Est 582 002 897 114 Rod Abrão Assed Km 53 450m Cx Postal 782 CEP 14097 500 Ribeirão Preto S P Brasil Telefone 55 16 3512 1212 Technical Duties Daniel R de Camargo CREA SP 5062199650 Registro ANVISA nº 10069210073 For greater safety Read and understand al...

Page 3: ...ronmental conditions in regular use conditions 12 Precautions and warnings during the use of equipment 13 Precautions and warnings after the use of equipment 13 Precautions in case of alteration in the functioning of equipment 13 Precautions to be adopted against foreseeable or uncommon risks related to the deactivation and abandoning of equipment 13 Environmental impact reduction precautions 14 E...

Page 4: ...problems Please read it and keep this with you Indication of Use The Alliage handpieces are intended to remove caries remove restorations and perform tooth sectioning as an aid in extracting teeth and they are for exclusive dental use and must be handled by trained qualified and regulated health professionals according to local legislation Contraindication None known ...

Page 5: ...n Alliage Dental Handpieces are designed to perform most routine dental procedures in intraoral region treatments Operation principle The Air motors operates by pneumatic pressure and has an Intra connection system to be used with Low Speed Dental Handpieces Significant physical characteristics The Air motors promotes shaft revolutions in the magnitude of 5 000 to 20 000 revolutions minute and has...

Page 6: ...e of an informative nature the equipment being able to differ from that illustrated So upon acquiring the product check the technical compatibilty between equipment coupling and accessories Models 01 Micromotor Intra SL 30 C Spray TB TM 02 Micromotor Intra SL 30 S Spray TB Micromotor Intra 32 MM S Spray TB 03 Micromotor Intra 32 MM C Spray TB TM Micromotor Intra SL 30 TB SI Micromotor Intra SL 30 ...

Page 7: ...g TB TM 02 O ring 03 Lubricant Lubs Attention The use of any part accessory or material not specified or foreseen in these instructions for use is entirely the user s responsibility Sets and Parts DESCRIPTION OF EQUIPMENT Optional ...

Page 8: ...pe 04 holes Coupling via the INTRA system Straight Piece and Contra Angle Sterilization Autoclavable up to 135ºC Coupling type Type 2 According to ISO 3964 Length X1 Long type max 31 8mm According to ISO 3964 Torque 0 350 1 000 N cm TECHNICAL SPECIFICATIONS General features Weights Model Net Weight Gross Weight 32 MM 77g 137g SL 30 80g 140g ABBREVIATIONS MM Air motors S Spray C Spray With Spray S ...

Page 9: ...e taken to a special waste collection site at the end of its useful life Attention Manufacturer Serial number Model number Manufacturing date To indicate a reference to spraying liquid Instructions for use Borden Type Terminal Stacking limit by number Keep dry This side Up Keep out of sunlight Fragile handle with care Temperature limitation 10 TECHNICAL SPECIFICATIONS ...

Page 10: ...10 Midwest Type Terminal Variability to the right Variability to the left Dimensions mm TECHNICAL SPECIFICATIONS BORDEN TYPE WITH SPRAY MIDWEST TYPE WITH SPRAY ...

Page 11: ...e wear of the bearings For the handpiece to function well it is necessary to have a driving pressure of 275 79 kpa 40 psi 2 75 bar Ring lock unlock Ring lock unlock fig a fig d fig c Regulator Ring fig b Type BORDEN Type MIDWEST Coupling of Air motors with handpieces Straight handpiece and Contra Angle Attaching the Contra Angle or Straight Part in the coupling of Air motors fig c To disengage by ...

Page 12: ...dictable environmental conditions in regular use conditions The equipment has been planned not to be sensitive to interference such as magnetic fields external electrical factors electrostatic discharge pressure or variance of pressure provided that the equipment is installed maintained clean preserved transported and operated as per this instruction for use Precautions and warnings during the use...

Page 13: ...ch it is intended Damages caused to the equipment the professional and or the patient by the incorrect installation and erroneous procedures of maintenance differing from those described in these Instructions for use which come with the equipment or by the incorrect operation of it Precautions for the Reduction of the Environment Impact Alliage S A aims to achieve an environmental policy that enco...

Page 14: ...d spread it on the surface to be treated Respect the antimicrobial contact time specified by the manufacturer The equipment can be reused in undetermined i e unlimited quantities only needing to be cleaned disinfected and Sterilization Additional procedures for reuse Handpieces may only be serviced in the field at the points described in the user manual If they need to be disassembled they must be...

Page 15: ...t the lubrication of your equipment we recommend the use of the Lubs product Lubrication must be carried out by the posterior hole of Air motors as illustrated in fig a Firmly fit the oil applicator nozzle into the hole indicated in fig a and apply the spray for 1 or 2 seconds fig b by holding the vial in vertical position Perform these operations spray lubrication with the regulating ring positio...

Page 16: ...e Attendance Service Alliage 55 16 3512 1212 Item Inspection description Recommended frequency Operating noise Audibly check the equipment for any ab normalities Daily Coupling Make sure that the Air motors is well fixed to the Delivery Unit terminal Daily Water leak Check if the spray holes are leaking water Monthly Clogging Check that the spray holes are not blocked Monthly Periodic Inspection I...

Page 17: ...screwdriver push the lining carefully downwards fig c Spray Regulation Spray cooling requires at least 50 cm3 min of water An insufficient amount of water can lead to overheating of the tooth With the terminal register open and the instrument working with Bur slowly close the register until the desired spray is achieved Maintenance of the MIDWEST Type Lining Use the same procedure as the BORDEN ty...

Page 18: ...ance of O Ring Change Insert a screwdriver of 1 2mm in the channel of the O ring moving it outwards fig a and b In order to fasten the new ring execute the opposite process without the screwdriver fig c INSPECTION AND MAINTENANCE ...

Page 19: ... spare parts replacement To ensure the lifetime of your device only replace original spare parts from Alliage They have the assurance of the standards and technical specifications required by the Alliage representative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for th...

Page 20: ......

Reviews: