background image

7

GB

The temperature of the fluid being pumped must never exceed 35° C. 

The  pump  must  not  be  used  to  pump  salt  water,  sewage,  flammable,  corrosive  or  explosive 
liquids (e.g. petroleum oil, petrol, and thinners), grease, oils or foodstuffs.  

Comply with the rules and regulations of the local water authority when using the pump for the 
supply of domestic water. 

3. 

STARTING THE PUMP 

Given the different provisions applicable to the safety of electric systems in different countries, 
make  sure  that  the  pump  system,  as  concerns  its  intended  use,  is  in  accordance  with  current 
legislation. 

Before starting the pump, make sure that: 

x

the  voltage  and  frequency  specified  on  the  pump’s  nameplate  coincide  with  those  of  the 
available power supply; 

x

there are no signs of damage to the pump or its power cord; 

x

the electric connection is made in a dry place, protected against any risk of flooding; 

x

the  electric  system  is  complete  with  a  residual  current  circuit-breaker  (I 

¨

n

”

  30  mA)  and  an 

efficient earthing connection; 

x

Any extension cords must comply with the requirements for electric safety.  

Fill  the  pump  casing  and  suction  hose  with  clean  water  before  starting  the  pump  for  the  first 
time.  If  the  pump  is  installed  above  the  water  level,  filling  must  be  performed  slowly  until  the 
water overflows; wait a few seconds to make sure that all the  air has escaped and top up until 
the level has stabilised.    
If the pump is installed below the water level (below head), bleed the air from the pump casing 
by opening the filler cap. The pump   will fill with water independently. 
Plug  the  pump  into  the  socket,  start  the  pump  and  wait  for  the  water  to  exit.  If  water  has  not 
exited  within  2-3  minutes  from when  the  pump  was  switched  on,  turn  the  pump  off  and  repeat 
the filling operation again.   

Attaching the suction hose 

x

Fit the suction hose from the water source to the pump making sure that the pump is above the 

  water level. Do not position the suction hose above the level of the pump (to avoid air bubbles forming in 

the suction hose). 

x

The suction hose should be mounted in such a way that it does not create any mechanical stress on the 

pump. 

x

The foot valve should be placed at least 30 cm below the minimum water level. 

x

The pump will draw water only when the suction hose is completely filled with water. 

x

The suction hose and the pump’s suction inlet should be of the same diameter. 

Attaching the delivery hose 

x

To get the best performance from the pump, it is recommended that the diameter of the delivery hose 

  is at least 1” 

x

During the self-priming phase, all taps, valves, etc. on the delivery hose must be fully open in 

  order to allow the air inside the hose to escape.  

Before plugging in and starting the pump for the first time, it is necessary that the suction hose and the pump 
are completely filled with water in order for suction to take place. For use in wells or when the water level is 
lower  than  the  pump,  a  suction  hose  must  be  used  that  is  equipped  with  the  foot  valve.  This  will  allow  the 
suction hose to remain filled with water after the first time that it is filled and will prevent the emptying of the 
hose when the pump shuts off automatically, avoiding any problems when restarting.  

Summary of Contents for MULTI INOX

Page 1: ...RUZIONI BETRIEBSANLEITUNG MANUAL DE INSTRUCCIONES INSTRUCTIEHANDLEIDING OHJEKIRJA MANUAL DE INSTRUÇÕES BRUKSANVISNING РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ INSTRUKýNÍ MANUÁL PRIROýNIK Z NAVODILI NÁVOD NA OBSLUHU PRIRUýNIK S UPUTAMA PRIRUýNIK SA UPUSTVIMA ПРИРАЧНИК СО ИНСТРУКЦИИ KEZELÉSI ÚTMUTATÓ BOOSTERSILENT MULTI INOX ...

Page 2: ...ause of the overheating See Troubleshooting 2 USE OF THE VARIOUS TYPES OF PUMPS 2 1 Self priming multi impeller surface pumps Available with 1 3 4 or 5 impellers The range of products includes pumps with stainless steel casings as well as plastic casings x suitable for domestic water supplies and for small and medium gardens x Ideal for emptying small tanks The pumps are made of chlorine resistant...

Page 3: ...the filler cap The pump will fill with water independently Plug the pump into the socket start the pump and wait for the water to exit If water has not exited within 2 3 minutes from when the pump was switched on turn the pump off and repeat the filling operation again Attaching the suction hose x Fit the suction hose from the water source to the pump making sure that the pump is above the water l...

Page 4: ...ay continues to signal the lack of water from the first intervention of the dry run protection up until the pump starts to operate correctly flashing red LED with one flash and one pause After having re established the flow of water press the RESET button to restart the pump x Electronic display signals Greed Led Power on The pump is connected to the main power and is ready to supply water as soon...

Page 5: ... The pump turns but does not deliver water 1 the air inside the pump has not been completely bled Pump casing without water 2 entry of air from the suction pipe 3 the suction valve is not submerged in water suction valve blocked the maximum suction depth has been exceeded 1 stop the pump unscrew the delivery pipe shake the pump and suction hose to remove any air bubbles Top up with water connect t...

Page 6: ...ours ago Check that the suction hose has been fitted correctly Power is on Pump on is off Alarm is flashing Impeller blocked thermal cut out tripped Clean free the pump Lack of water for more than 26 hours Check that the suction hose has been fitted correctly The pump does not work Power is on Pump on is off Alarm is on Impeller blocked thermal cut out tripped Clean the pump Excessive suction dept...

Page 7: ...used correctly and in compliance with the instructions The guarantee becomes null and void in the event of the following y unauthorized attempts to repair the appliance y unauthorized technical changes to the appliance y use of non original spare parts y manhandling y inappropriate use e g for industrial purposes The guarantee does not cover y parts liable to rapid wear and tear For any action und...

Page 8: ... info belgium dwtgroup com Tel 32 2 4668353 Fax 32 2 4669218 DAB PUMPS IBERICA S L Avenida de Castilla nr 1 Local 14 28830 San Fernando De Henares Madrid Spain info spain dwtgroup com Ph 34 91 6569545 Fax 34 91 6569676 PUMPS AMERICA INC DAB PUMPS DIVISION 3226 Benchmark Drive Ladson SC 29456 USA info usa dwtgroup com Ph 1 843 824 6332 Toll Free 1 866 896 4DAB 4322 Fax 1 843 797 3366 OOO DWT GROUP ...

Reviews: