1. 

SAFETY MEASURES 

 Before starting the pump, read this instruction booklet carefully and keep it in a safe place for 
future reference 
For safety reasons, the pump must not be used by anyone who has not read these instructions. 

 The power cord must never be used to carry or move the pump. Always use the pump’s handle.

 When handling the pump, while it is connected to the electric power supply, you should avoid 
all contact with water.

 Never remove the plug by pulling on the power cord.

 Before taking any action on the pump, always remove the plug from the power socket. 

 If  the  power  supply  cord  has  been  damaged,  it  must  be  replaced  by  the  manufacturer  or  his 
authorized customer support service 

in order to avoid all risks. 

 Overload  protection.  The  pump  has  a  thermal  overload  safety  device.  In  the  event  of  any 
overheating  of  the  motor,  this  device  automatically  switches  off  the  pump.  The  cooling  time  is 
roughly 15 to 20 minutes, then the pump automatically comes on again. If the overload cut-out is 
tripped,  it  is  essential  to  identify  and  deal  with  the  cause  of  the  overheating.  See 
Troubleshooting. 

2. 

USE OF THE VARIOUS TYPES OF PUMPS 

2.1 Self priming multi-impeller surface pumps

Available  with  1,  3,  4  or  5  impellers.  The  range  of  products  includes  pumps  with  stainless  steel  casings as 
well as plastic casings. 

x

suitable for domestic water supplies and for small and medium gardens.   

x

Ideal  for  emptying  small  tanks.  The  pumps  are  made  of  chlorine  resistant  materials  (normal 
concentration). 

x

Suitable for irrigation, drawing from water collection tanks  

2.3 Boosters with integrated electronics 

Characterised by their extremely silent running, and available with 3, 4 and 5 impellers.  

x

Including an electronic safety device to prevent the dry-running of the pump. 

x

Ideal for the irrigation of gardens and grounds, and domestic water supplies.  

x

Characterised by the constant pressure and flow-rate. 

2.2

The appliance is not intendend for use by persons (including children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction con-
cerning use of the appliance by a person responsable for their safety. Children should be supervised to ensure 
that they do not play with the appliance. (CEI EN 60335-1 : 08)

(MULTI INOX)

(BOOSTERSILENT)

Summary of Contents for MULTI INOX

Page 1: ...RUZIONI BETRIEBSANLEITUNG MANUAL DE INSTRUCCIONES INSTRUCTIEHANDLEIDING OHJEKIRJA MANUAL DE INSTRUÇÕES BRUKSANVISNING РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ INSTRUKýNÍ MANUÁL PRIROýNIK Z NAVODILI NÁVOD NA OBSLUHU PRIRUýNIK S UPUTAMA PRIRUýNIK SA UPUSTVIMA ПРИРАЧНИК СО ИНСТРУКЦИИ KEZELÉSI ÚTMUTATÓ BOOSTERSILENT MULTI INOX ...

Page 2: ...ause of the overheating See Troubleshooting 2 USE OF THE VARIOUS TYPES OF PUMPS 2 1 Self priming multi impeller surface pumps Available with 1 3 4 or 5 impellers The range of products includes pumps with stainless steel casings as well as plastic casings x suitable for domestic water supplies and for small and medium gardens x Ideal for emptying small tanks The pumps are made of chlorine resistant...

Page 3: ...the filler cap The pump will fill with water independently Plug the pump into the socket start the pump and wait for the water to exit If water has not exited within 2 3 minutes from when the pump was switched on turn the pump off and repeat the filling operation again Attaching the suction hose x Fit the suction hose from the water source to the pump making sure that the pump is above the water l...

Page 4: ...ay continues to signal the lack of water from the first intervention of the dry run protection up until the pump starts to operate correctly flashing red LED with one flash and one pause After having re established the flow of water press the RESET button to restart the pump x Electronic display signals Greed Led Power on The pump is connected to the main power and is ready to supply water as soon...

Page 5: ... The pump turns but does not deliver water 1 the air inside the pump has not been completely bled Pump casing without water 2 entry of air from the suction pipe 3 the suction valve is not submerged in water suction valve blocked the maximum suction depth has been exceeded 1 stop the pump unscrew the delivery pipe shake the pump and suction hose to remove any air bubbles Top up with water connect t...

Page 6: ...ours ago Check that the suction hose has been fitted correctly Power is on Pump on is off Alarm is flashing Impeller blocked thermal cut out tripped Clean free the pump Lack of water for more than 26 hours Check that the suction hose has been fitted correctly The pump does not work Power is on Pump on is off Alarm is on Impeller blocked thermal cut out tripped Clean the pump Excessive suction dept...

Page 7: ...used correctly and in compliance with the instructions The guarantee becomes null and void in the event of the following y unauthorized attempts to repair the appliance y unauthorized technical changes to the appliance y use of non original spare parts y manhandling y inappropriate use e g for industrial purposes The guarantee does not cover y parts liable to rapid wear and tear For any action und...

Page 8: ... info belgium dwtgroup com Tel 32 2 4668353 Fax 32 2 4669218 DAB PUMPS IBERICA S L Avenida de Castilla nr 1 Local 14 28830 San Fernando De Henares Madrid Spain info spain dwtgroup com Ph 34 91 6569545 Fax 34 91 6569676 PUMPS AMERICA INC DAB PUMPS DIVISION 3226 Benchmark Drive Ladson SC 29456 USA info usa dwtgroup com Ph 1 843 824 6332 Toll Free 1 866 896 4DAB 4322 Fax 1 843 797 3366 OOO DWT GROUP ...