ENGLISH
30
15. TROUBLESHOOTING
Type of problem
Causes
Solutions
The pump does not start
Switch in stop position (O)
Change to manual (
I
) or automatic (
II
)
position
The minimum flow rate does not allow
the flow switch to start (the rate must be
more than 2.5 l/Min)
Change to manual position (
I
)
No current
Check fuse and power supply
Presence of material on the flow switch
To clean the flow switch, follow the
instructions in point 13
Starting capacitor damaged
Change the capacitor
The pump does not
generate pressure
Main valve closed
Open main valve
Presence of air in the system
Turn on the tap, activate the pump
Impeller damaged
Change the impeller
The pump is vibrating in an
abnormal way without
making noise
Unstable installation
Adjust the loose parts
The pump is vibrating,
abnormal rattling
Cavitation
Reduce the height of the input pipe,
increasing its diameter
Overpressure
Move the output valve or change the
model
The pump is vibrating,
abnormal friction noise
Impeller partly blocked by presence of
metal material
Remove the material
Mechanical seal damaged
Change the seal or the washer
Motor shaft is damaged
Change the motor shaft
The cover of the fan motor is rubbing
against the fan
Fit the fan cover again
The pump starts even if the
tap is turned off
Switch in manual position (
I
)
Change to automatic (
II
) or stop
position (0).
Flow switch not working due to presence
of material
To clean the flow switch, follow the
instructions in point 13
Flow switch damaged
Change the flow switch
16. DISPOSAL
This product or any part of it must be disposed of correctly:
-
Use public or private local systems for waste collection.
-
If that is not possible, contact Dab Pumps or the nearest authorised service workshop
Summary of Contents for K 40/22 HA
Page 2: ...ITALIANO pag 1 FRAN AIS pag 11 ENGLISH pag 21 ESPA OL p g 31 PORTUGU S p g 41 51 61 Rte IZk...
Page 56: ...54 7 7 1 K...
Page 57: ...55 7 2 1 5 6 9 1 H 1 2 H 1 3 5 6 4 5 I MAN II AUT O STOP 100 C I MAN 8...
Page 58: ...56 30 A I 30 A 14 4 65 9 10 0 C 11 I MAN II AUT O...
Page 59: ...57 12 13 14 14 1...
Page 60: ...58 14 2 220V PCB 3...
Page 62: ...60 15 O I II 2 5 I 13 I II 0 13 16 Dab Pumps...
Page 66: ...IZk 64 1 7 K...
Page 70: ...IZk 68 2 14 220V PCB...
Page 72: ...IZk 70 15 O I II 25 I 13 I II 0 13 16 Dab Pumps...
Page 73: ......
Page 74: ......
Page 75: ......