background image

ENGLISH 

17 

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE 

 

 

 

Installation and functioning must comply with the safety regulations in force in the 
country in which the product is installed.  The entire operation must be carried out in a 
workmanlike manner. 
Failure to comply with the safety regulations not only causes risk to personal safety and 
damage to the equipment, but invalidates every right to assistance under guarantee. 

 

APPLICATIONS 

The 

FEKA VS-VX

 pump is a submersible centrifugal pump made of stainless steel with a vortex 

back impeller, designed and built for use with dirty water from septic tanks and dirty water in 
general containing solid bodies with maximum diameter 50 mm, but only for non-aggressive water. 
Thanks to the radial delivery aperture (2" female) it may be easily fitted on lifting devices (type 
DSD2). 
The float, where fitted, allows fixed installation and guarantees automatic pumping operation. 

 

The 

DRENAG 1000 - 1200

 pump is of submersible centrifugal type, made completely of stainless 

steel with a clearance impeller, designed and built to pump clear waste water, sandy, muddy and 
sludgy waters, without fibre, containing solid bodies with maximum dimensions up to 10 mm in 
diameter, but always non-aggressive waters.  Suitable for domestic and building-site uses in fixed 
applications, with manual or automatic operation, for draining cellars and garages prone to flooding, 
for pumping drains, rainwater traps or infiltrations from gutters, excavations, etc.  Thanks to their 
compact shape and easy manoeuvrability and to the vertical delivery mouth with male thread, they are 
also suitable for particular applications as portable pumps for emergency uses, such as for drawing 
water from tanks or rivers, draining swimming pools or fountains, excavations or underpasses.  Also 
suitable for gardening and hobby uses in general. 
The float, where fitted, allows fixed installation and guarantees automatic pumping operation. 

 

These pumps cannot be used in swimming pools, ponds or tanks in which people 
or present, or for pumping hydrocarbons (petrol, diesel fuel, fuel oils, solvents, 
etc.) in accordance with the accident-prevention regulations in force.

 

 

N.B.

 The liquid inside the pump, to lubricate the seal device, is not toxic but it may alter the 

characteristics of the water (if it is pure water) if there is a leak in the seal device. 

 
 

TECHNICAL DATA AND LIMITS ON USE 

 

Supply voltage

1 X 220/240V 50Hz 
3 X 400V 50Hz 
3 X 230V 50Hz 

1 X 220/230V 60Hz 
3 X 230V 60Hz 
3 X 380/400V 60Hz 

 

Flow rate: 

see electric data plate

 

Hmax ( m ) - 

Head: 

pag. 

135 

 

Degree of motor protection: 

see electric data plate

 

Protection class: 

see electric data plate

 

Absorbed power: 

see electric data plate

 

Liquid temperature range: 

 

from 0°C to +35°C for domestic use (safety 
standards EN 60335-2-41) 

 

from 0°C to +50°C for other uses 

 

Maximum immersion: 

10 metres 

 

Storage temperature: 

-10°C to +40°C 

 

Noise level: 

Falls within the limits envisaged by EC Directive 
89/392/EEC and subsequent modifications. 

 
 
 
 
 

Summary of Contents for FEKA VS

Page 1: ...INGEBRUIKNAME EN ONDERHOUD POKYNY K IN TAL CII A DR BE KULLANIM VE BAKIM TAL MATLARI INSTALLATIONS OCH UNDERH LLSANVISNING INSTRUCCIONES PARA LA INSTALACI N Y EL MANTENIMIENTO INSTRU ES PARA A INSTALA...

Page 2: ...VS VX Checking and changing the oil DRENAG 1000 1200 Modifications and spare parts Troubleshooting 17 17 18 18 18 19 20 20 20 20 21 21 22 23 24 24 Anwendungen Technische Daten und Einsatzgrenzen Hinwe...

Page 3: ...e to flooding for pumping drains rainwater traps or infiltrations from gutters excavations etc Thanks to their compact shape and easy manoeuvrability and to the vertical delivery mouth with male threa...

Page 4: ...st never be allowed to run dry 6 The Manufacturer does not vouch for correct operation of the pump if it is tampered with or modified INSTALLATION 1 If the bottom of the well or borehole in which the...

Page 5: ...n the base bracket in contact with the pump suction strainer near the delivery aperture secure everything to the strainer cover with the screws provaided to lock the strainer cover Remove the top scre...

Page 6: ...ired or replaced by skilled and qualified personnel CHECKING THE DIRECTION OF ROTATION for three phase motors Fig 4 The direction of rotation must be checked each time a new installation is made Proce...

Page 7: ...h substances which tend to form a deposit rinse it after use with a powerful jet of water so as to avoid the formation of deposits or scale which would tend to reduce the yield of the pump MAINTENANCE...

Page 8: ...hole 64 and catch it in a container Analyse the oil if you find any particles of water or abrasive materials for example sand it is advisable to check the condition of the mechanical seal 16 and to ha...

Page 9: ...out of the hole of the cap 64 and pour it into a container Analyse the oil if you find any particles of water or abrasive materials for example sand it is advisable to check the condition of the mecha...

Page 10: ...e strainer E The required head is higher than the pump characteristics A Remove the blockage B Change the impeller or remove the blockage C Check that the valve is operating correctly and replace it i...

Page 11: ...evalencia Maximal pumph jd Manometrik y kseklik x tK A Nostokorkeus Wysoko ci nienia Hmax m 2 poles 50 Hz Hmax m 2 poles 60 Hz FEKA VS 550 7 4 7 4 FEKA VS 750 9 6 9 6 FEKA VS 1000 11 8 11 8 FEKA VS 12...

Page 12: ...Fernando De Henares Madrid Spain info spain dwtgroup com Ph 34 91 6569545 Fax 34 91 6569676 PUMPS AMERICA INC DAB PUMPS DIVISION 3226 Benchmark Drive Ladson SC 29456 USA info usa dwtgroup com Ph 1 843...

Reviews: