background image

DAB PUMPS LTD.

Units 4 & 5, Stortford Hall Industrial Park,

Dunmow Road, Bishop’s Stortford, Herts

CM23 5GZ - UK

[email protected]

Tel.: +44 1279 652 776

Fax: +44 1279 657 727

DAB PUMPEN DEUTSCHLAND GmbH

Tackweg 11

D - 47918 Tönisvorst - Germany

[email protected]

Tel.: +49 2151 82136-0 

Fax: +49 2151 82136-36

DAB UKRAINE Representative Office

Regus Horizon Park 

4M. Hrinchenka St, suit 147

03680 Kiev. UKRAINE

Tel. +38 044 391 59 43

DAB PRODUCTION HUNGARY KFT.

H-8800

NAGYKANIZSA, Buda Ernó u.5

HUNGARY

Tel. +36.93501700

DAB PUMPS B.V.

Albert Einsteinweg, 4

5151 DL Drunen - Nederland

[email protected]

Tel.: +31 416 387280

Fax: +31 416 387299

DAB PUMPS B.V.

Brusselstraat 150

B-1702 Groot-Bijgaarden - Belgium

[email protected]

Tel.: +32 2 4668353

Fax: +32 2 4669218

DAB PUMPS IBERICA S.L.

Avenida de Castilla nr.1 Local 14

28830 - San Fernando De Henares - Madrid 

Spain

[email protected]

Ph.: +34 91 6569545

Fax: +34 91 6569676

PUMPS AMERICA, INC. DAB PUMPS DIVISION 

3226 Benchmark Drive

Ladson, SC 29456 USA

[email protected]

Ph. 

: 1-843-824-6332 

Toll Free : 1-866-896-4DAB (4322)

Fax 

: 1-843-797-3366

OOO DWT GROUP

100 bldg. 3 Dmitrovskoe highway, 

127247 Moscow - Russia

[email protected] 

Tel.: +7 495 739 52 50

Fax: +7 495 485-3618

DAB PUMPS CHINA 

No.40 Kaituo Road, Qingdao Economic & 

Technological Development Zone 

Qingdao City, Shandong Province, China 

PC: 266500 

[email protected] 

Tel.: +8653286812030-6270

Fax: +8653286812210 

DAB PUMPS S.p.A.

Via M. Polo, 14 - 35035 Mestrino (PD) - Italy

Tel. +39 049 5125000 - Fax +39 049 5125950

www.dabpumps.com

DWT South Africa 

Podium at Menlyn, 3rd Floor, Unit 3001b, 

43 Ingersol Road, C/O Lois and Atterbury, 

Menlyn, Pretoria, 0181 South-Africa 

[email protected] 

Tel +27 12 361 3997 

Fax +27 12 361 3137

DAB POLAND - Representative Office

Mokotow Marynarska

Ul. Postepu 15c - 3rd Floor

02-676 Warsaw - POLAND

Tel. +48 223 81 6085

0

6

/14  cod.

60110127

Summary of Contents for FEKA VS

Page 1: ...INGEBRUIKNAME EN ONDERHOUD POKYNY K IN TAL CII A DR BE KULLANIM VE BAKIM TAL MATLARI INSTALLATIONS OCH UNDERH LLSANVISNING INSTRUCCIONES PARA LA INSTALACI N Y EL MANTENIMIENTO INSTRU ES PARA A INSTALA...

Page 2: ...VS VX Checking and changing the oil DRENAG 1000 1200 Modifications and spare parts Troubleshooting 17 17 18 18 18 19 20 20 20 20 21 21 22 23 24 24 Anwendungen Technische Daten und Einsatzgrenzen Hinwe...

Page 3: ...e to flooding for pumping drains rainwater traps or infiltrations from gutters excavations etc Thanks to their compact shape and easy manoeuvrability and to the vertical delivery mouth with male threa...

Page 4: ...st never be allowed to run dry 6 The Manufacturer does not vouch for correct operation of the pump if it is tampered with or modified INSTALLATION 1 If the bottom of the well or borehole in which the...

Page 5: ...n the base bracket in contact with the pump suction strainer near the delivery aperture secure everything to the strainer cover with the screws provaided to lock the strainer cover Remove the top scre...

Page 6: ...ired or replaced by skilled and qualified personnel CHECKING THE DIRECTION OF ROTATION for three phase motors Fig 4 The direction of rotation must be checked each time a new installation is made Proce...

Page 7: ...h substances which tend to form a deposit rinse it after use with a powerful jet of water so as to avoid the formation of deposits or scale which would tend to reduce the yield of the pump MAINTENANCE...

Page 8: ...hole 64 and catch it in a container Analyse the oil if you find any particles of water or abrasive materials for example sand it is advisable to check the condition of the mechanical seal 16 and to ha...

Page 9: ...out of the hole of the cap 64 and pour it into a container Analyse the oil if you find any particles of water or abrasive materials for example sand it is advisable to check the condition of the mecha...

Page 10: ...e strainer E The required head is higher than the pump characteristics A Remove the blockage B Change the impeller or remove the blockage C Check that the valve is operating correctly and replace it i...

Page 11: ...evalencia Maximal pumph jd Manometrik y kseklik x tK A Nostokorkeus Wysoko ci nienia Hmax m 2 poles 50 Hz Hmax m 2 poles 60 Hz FEKA VS 550 7 4 7 4 FEKA VS 750 9 6 9 6 FEKA VS 1000 11 8 11 8 FEKA VS 12...

Page 12: ...Fernando De Henares Madrid Spain info spain dwtgroup com Ph 34 91 6569545 Fax 34 91 6569676 PUMPS AMERICA INC DAB PUMPS DIVISION 3226 Benchmark Drive Ladson SC 29456 USA info usa dwtgroup com Ph 1 843...

Reviews: