background image

 

135 

 

Modello / Modèle / Model 

/Modell / Model /Modelo 

Modell / Model / 

Модель

  

QY¥}

 

/ Malli / Model

 

Prevalenza / Hauteur d'élévation / Head up 

Förderhöhe / Overwicht / Prevalencia 

Maximal pumphöjd / Manometrik yükseklik /

Напор

  

 

x¥tK{A / 

 Nostokorkeus /  Wysoko

ść

 ci

ś

nienia

 

 

 

Hmax (m) 2 poles   50 Hz 

 

 

Hmax (m) 2 poles   60 Hz 

 

FEKA VS 550 

7.4 

7.4 

FEKA VS 750 

9.6 

9.6 

FEKA VS 1000 

11.8 

11.8 

FEKA VS 1200 

14 

15.2 

FEKA VX 550 

7.4 

7.4 

FEKA VX 750 

9.6 

9.6 

FEKA VX 1000 

11.8 

11.8 

FEKA VX 1200 

14 

15.2 

DRENAG 1000 

15.3 

15.3 

DRENAG 1200 

17 

17 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for FEKA VS

Page 1: ...INGEBRUIKNAME EN ONDERHOUD POKYNY K IN TAL CII A DR BE KULLANIM VE BAKIM TAL MATLARI INSTALLATIONS OCH UNDERH LLSANVISNING INSTRUCCIONES PARA LA INSTALACI N Y EL MANTENIMIENTO INSTRU ES PARA A INSTALA...

Page 2: ...VS VX Checking and changing the oil DRENAG 1000 1200 Modifications and spare parts Troubleshooting 17 17 18 18 18 19 20 20 20 20 21 21 22 23 24 24 Anwendungen Technische Daten und Einsatzgrenzen Hinwe...

Page 3: ...e to flooding for pumping drains rainwater traps or infiltrations from gutters excavations etc Thanks to their compact shape and easy manoeuvrability and to the vertical delivery mouth with male threa...

Page 4: ...st never be allowed to run dry 6 The Manufacturer does not vouch for correct operation of the pump if it is tampered with or modified INSTALLATION 1 If the bottom of the well or borehole in which the...

Page 5: ...n the base bracket in contact with the pump suction strainer near the delivery aperture secure everything to the strainer cover with the screws provaided to lock the strainer cover Remove the top scre...

Page 6: ...ired or replaced by skilled and qualified personnel CHECKING THE DIRECTION OF ROTATION for three phase motors Fig 4 The direction of rotation must be checked each time a new installation is made Proce...

Page 7: ...h substances which tend to form a deposit rinse it after use with a powerful jet of water so as to avoid the formation of deposits or scale which would tend to reduce the yield of the pump MAINTENANCE...

Page 8: ...hole 64 and catch it in a container Analyse the oil if you find any particles of water or abrasive materials for example sand it is advisable to check the condition of the mechanical seal 16 and to ha...

Page 9: ...out of the hole of the cap 64 and pour it into a container Analyse the oil if you find any particles of water or abrasive materials for example sand it is advisable to check the condition of the mecha...

Page 10: ...e strainer E The required head is higher than the pump characteristics A Remove the blockage B Change the impeller or remove the blockage C Check that the valve is operating correctly and replace it i...

Page 11: ...evalencia Maximal pumph jd Manometrik y kseklik x tK A Nostokorkeus Wysoko ci nienia Hmax m 2 poles 50 Hz Hmax m 2 poles 60 Hz FEKA VS 550 7 4 7 4 FEKA VS 750 9 6 9 6 FEKA VS 1000 11 8 11 8 FEKA VS 12...

Page 12: ...Fernando De Henares Madrid Spain info spain dwtgroup com Ph 34 91 6569545 Fax 34 91 6569676 PUMPS AMERICA INC DAB PUMPS DIVISION 3226 Benchmark Drive Ladson SC 29456 USA info usa dwtgroup com Ph 1 843...

Reviews: