ENGLISH
49
13. DRAINING FUNCTION
In draining function (drainage) the floats, if present, are positioned in this order:
Do not touch and clean the sensor membrane with your hands, screwdrivers, brushes, etc.!
Do not clean the membrane with compressed air!
The transmitter must be steeped in water and cleaned only with soap and water or with
alcohol!
Do not drop the transmitter and do not tap it on the table to get the residue out!
Do not blow into the cable compensation hose! Do not pull the cable!
13.1 Operation with 2 floats
In operation with 2 floats, Pump P1 starts with the closed contact of the float B, while Pump P2 starts with the
closed contact of the float C.
Both pumps stop with the open contact of the float B.
The following table sums up the behaviour described:
Sequence
Pump P1
Pump P2
START
Float B = NC
Float C = NC
STOP
Float B+C = NO
Float B+C = NO
13.2 Operation with 3 floats
In operation with 3 floats, Pump P1 starts with the closed contact of the float B, while Pump P2 starts with the
closed contact of the float C.
The pumps stop with the open contact of the float A which controls the minimum level for both.
The following table sums up the behaviour described:
Sequence
Pump P1
Pump P2
START
Float B = NC
Float C = NC
STOP
Float A+B+C = NO
Float A+B+C = NO
N.B. Instead of the floats, electric probes may be connected.
ONLY WITH CLEAN CLEAR WATER!
analog level sensor
ELECTRIC
PANEL
Summary of Contents for E-BOX 2G M
Page 133: ...129 7 QS1 OFF 0 L1 L2 L3 L N 230 400 7 1 L1 L2 L3 L1 L2 L3...
Page 137: ...133 9 0 OFF I ON 1 2 3 4 5 6 7 8 9 1 2 3 1 4 5 1 6 1 3 2 7 8 2 9 2 3...
Page 141: ...137 24 DS_A2 2 12 12 1 2 2 1 2 1 2 12 2 3 3 1 2 1 2...
Page 143: ...139 13 13 1 2 2 1 2 1 2 13 2 3 3 1 2 1 2...
Page 148: ...144 15 EXP 1 16 8 2 5x20 T 100 3 4 230 10 5 EXP 1 2 3 4 5...
Page 169: ...165 7 OFF 0 L1 L2 L3 L N QS1 230V 400V 7 1 L1 L2 L3 L1 L2 L3...
Page 173: ...169 9 0 OFF I ON 1 2 3 4 5 6 7 8 9 1 2 3 RESET P1 4 5 P1 6 P1 3 P2 7 8 P2 9 P2 3...
Page 179: ...175 13 13 1 2 2 P1 B P2 C B P1 P2 B C B C B C 13 2 3 3 P1 B P2 C P1 P2 B C A B C A B C 13 3...
Page 184: ...180 15 EXP EXP 1 16 8 2 5x20 T 100mA 3 4 230VAC 10VA 5 EXP 1 2 3 4 5...
Page 186: ......
Page 187: ......
Page 188: ......
Page 189: ......
Page 190: ......
Page 191: ......