1. PUMPED FLUIDS ................................................................................................................................................................................................. 7

 

2. TECHNICAL DATA AND LIMITS ON USE ........................................................................................................................................................... 7

 

3. WARNINGS ........................................................................................................................................................................................................... 7

 

4. INSTALLAZIONE .................................................................................................................................................................................................. 7

 

5. ELECTRIC CONNECTION .................................................................................................................................................................................... 8

 

6. CHECKING THE DIRECTION OF ROTATION (for three-phase motors) .......................................................................................................... 8

 

7. STARTING UP ...................................................................................................................................................................................................... 8

 

Adjusting the float switch ................................................................................................................................................................................... 8

 

8. PRECAUTIONS ..................................................................................................................................................................................................... 8

 

9. MAINTENANCE AND CLEANING ........................................................................................................................................................................ 8

 

Checking and changing the sealing oil ............................................................................................................................................................. 8

 

10. TROUBLESHOOTING ........................................................................................................................................................................................ 9 

1. PUMPED FLUIDS

 

These pumps cannot be used in swimming pools, ponds or tanks in which people or present, or for pumping hydrocarbons 

(petrol, diesel fuel, fuel oils, solvents, etc.) in accordance with the accident-prevention regulations in force. 

N.B.: The liquid inside the pump, to lubricate the seal device, is not toxic but it may alter the characteristics of the water (if it is pure water) if there

is a leak in the seal device.

2. TECHNICAL DATA AND LIMITS ON USE

Supply voltage:

1 X 220/240V 50Hz 

3 X 400V 50Hz 

3 X 230V 50Hz 

1 X 220/230V  60Hz 

3 X 230V 60Hz 

3 X 380/400V 60Hz 

see electric data plate 

Flow rate: see electric data plate

Hmax ( m ) - Head: 

57 ft (17.5 m)

Degree of motor protection / Protection class:  see electric data plate

Absorbed power:  see electric data plate

Liquid temperature range:

from 32°F - 95°F (0°C to +35°C) for domestic use

 (safety standards EN 60335-2-41)

f

rom 32°F - 122°F (0°C to +50°C) for other uses

Maximum immersion: 

32.8  ft  (

10 m

).

Storage temperature: 

14°F  -  104°F  (

-10°C +40°C

)

Noise level:  Falls within the limits envisaged by EC Directive 89/392/EEC and subsequent modifications.

3. WARNINGS

The pump is provided with a carrying handle which may also be used to lower it into wells or deep holes with a rope or cable.

If the power cable is damaged in any way it must be replaced and not repaired (use cable type H07RN-F diam. 9 – 9.5 mm. with minimum

length 10 metres for the portable version, with a UNEL 47166-68 plug for the SINGLE-PHASE version and with an EEC plug for the THREE-

PHASE version).This must be done by skilled personnel, in possession of the qualifications required by the regulations in force.

The pump must never be allowed to run dry.

4. INSTALLAZIONE

4.1  If the bottom of the well or borehole in which the pump is to operate is particularly dirty, it is advisable to provide a support for the pump to

sit on so as to avoid clogging of the intake grid (Fig.1). 

4.2  Before putting the pump in position, ensure that the strainer is not totally or partially blocked by mud, sediment or similar substances. 

4.3  It is advisable to use pipes with an internal diameter at least equal to that of the delivery mouth, to avoid falls in pump performance and 

the possibility of clogging.  In cases where the delivery pipe has long horizontal stretches, it is advisable for this pipe to have a larger 

diameter than that of the delivery mouth. 

Totally immerse the pump in the water. 

4.4 

1.

 

Connect the delivery pipe or hose directly to the pump mouth.  If the pump is used in fixed

installations it is advisable to connect it to the pipe with a coupling so as to facilitate disassembly

and reinstallation.  If a hose is used, fit a threaded hosetail on the pump mouth.  Wrap the thread

with suitable material to ensure an effective seal (teflon tape or similar)

.

2.

 

On the version provided with a float switch, ensure that the float can move freely (SEE THE

PARAGRAPH ON ADJUSTING THE FLOAT SWITCH).  Ensure that the minimum

dimensions of the borehole are as in Fig.1.  The dimensions of the borehole must also be

calculated with relation to the quantity of water arriving and to the pump flow rate so as not to

subject the motor to excessive starting operations.

3.

 

When the pump is to be in a fixed installation, with a float, a check valve must always be fitted

in the delivery pipe.  This is also advisable on pumps with manual operation.

 

    23.6" x 23.6"

 

600

mm

x600

mm

O

N

O

F

F

Fig

.

1

Summary of Contents for DRENAG 1000

Page 1: ...INSTRUCTIONS DE MISE EN SERVICE ET D ENTRETIEN FR INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE EN DRENAG 1000 1200...

Page 2: ...tres pour version portable avec prise UNEL 47166 68 pour la version monophas e et avec prise CEE pour la version triphas e Il faut donc faire appel du personnel sp cialis et qualifi en possession des...

Page 3: ...s en marche automatiquement quand le niveau de l eau monte les mod les sans flotteur sont mis en marche au moyen d un interrupteur situ en amont de la prise non fourni Reglage de l interrupteur a flot...

Page 4: ...contacter le fournisseur 2 La pompe ne refoule pas A La cr pine d aspiration ou les tuyaux sont bouch s B La roue est us e ou bouch e C Le clapet de retenue s il est install sur le tuyau de refouleme...

Page 5: ...66 68 plug for the SINGLE PHASE version and with an EEC plug for the THREE PHASE version This must be done by skilled personnel in possession of the qualifications required by the regulations in force...

Page 6: ...be started more than 20 times in one hour so as not to subject the motor to excessive thermal shock 8 3 DANGER OF FROST When the pump remains inactive for a long time at temperatures of less than 0 C...

Page 7: ...the blockage B Change the impeller or remove the blockage C Check that the valve is operating correctly and replace it if necessary D Adjust the length of the float switch cable SEE THE PARAGRAPH ON A...