 After a short delay, during which you have positioned yourself within the device, the lamps 
will  turn  on  and  the  screen  will  track  your  progress.    The  lamps  will  shut  off  when  the 
treatment is over.   

7. 

To pause an active treatment, quickly leave the cabinet and press the Pause  

   button.   

To resume, press the Play 

  button. 

 

To end or cancel an active treatment, first pause 

the treatment, then press the Cancel 

   button.

 

13.0

 

 Timed Mode

 

13.1

 

Running a Treatment

 

After unlocking the device, the Treatment Screen will appear. 

1.

 

Press the “Treat Patient” button.

 

2.

 

Touch the ▲/▼ arrows to enter the desired treatment time.  

Note:

 It is 

not

 possible to enter a 

time of 60 seconds.  You must enter 1 minute instead. 

3.

 

Press the Enter 

  Arrow to enter the Treatment Confirmation screen.  

4.

 

Confirm the Time.

  

If a change is needed, press the Return   

  Arrow and return to step 

2. 

Put on your goggles 

5.

 

If the Time is correct, press the Enter   

  key to begin the treatment.  A several second 

countdown will begin.

 

 

Positioning:  

Open the doors, enter the treatment chamber, and close the doors behind you.  Face 

either the back or front of the device.  In order to receive even and effective treatments, center 
yourself within the unit.  As nearly as possible, your torso should not be closer to any one section 
of lamps than to another. Standing closer to one of the sides increases the likelihood of localized 
streaking and burning. 

6.

 

 After a short delay, during which you have positioned yourself within the device, the lamps 
will turn on and the screen will track your progress.  The lamps will shut off when the 
treatment is over.   

7.

 

To pause a treatment, quickly leave the cabinet and press the Pause  

   button.   To 

resume, press the Play 

  button.  To end or cancel a treatment, first pause the treatment, 

then press the Cancel   

  button. 

 

Calculating Increases:

  

Phototherapy treatments usually start at a given time or dose and are 

increased with each treatment.  Your doctor may ask you to increase each treatment by a set 
amount  of  time  or  may  ask  you  to  increase  by  a  percentage,  which  is  difficult  when  the 
treatment times are in minutes and seconds.  Google 

Daavlin treatment time calculator 

and 

bookmark it on your phone.  In that app, simply enter the time of your last treatment and the 
desired  percentage  increase  and  the  calculator  will  give  you  the  new  treatment  time 
instantaneously

Summary of Contents for ClearLink UV Series

Page 1: ...Company Confidential Printed copies will not be updated MNL 00002 4 Page 1 of 22 ClearLink Home Control Operation Manual Modes of Operation Guided Mode Dosimetric Mode Timed Mode...

Page 2: ...2 11 1 Features of the ClearLinkTM Guided Home Control System 12 11 2 Running a Treatment 13 12 0 Dosimetric Mode 14 12 1 Features of the ClearLink Dosimetric Home Control System 14 12 2 Running a Tre...

Page 3: ...00002 4 Page 3 of 22 15 0 Environmental Specifications 18 16 0 Warranty 20 16 1 Limited Warranty Policy 20 16 2 Warranty Coverage 21 16 3 Customer Responsibility 21 16 4 Warranty Service 21 16 5 Disp...

Page 4: ...imed You control the length of each treatment based on instructions from your doctor See pages 16 and 17 for operating instructions that are specific to this mode of operation FlexRx Your physician ma...

Page 5: ...The table and diagrams below define these requirements for each number of lamps Model Amps Wire Gauge Diagram Required Outlet 24 lamp 120 volt 20 amps 12 AWG A NEMA L5 30R 16 lamp 120 volt 15 amps 12...

Page 6: ...variety of different lamps each having a different effect on the skin It is important to check that the proper lamps are installed Consult the Lamp Specification Guide shown below and if there is any...

Page 7: ...nly be connected to a supply main with a protective earth To prevent electric shock remove power to the device prior to cleaning and servicing To eliminate the risk of fire when replacing the fuse rep...

Page 8: ...damage The device control system display is susceptible to damage from excessive force Avoid excessive force to the control system to prevent damage All treatments must be administered under the dire...

Page 9: ...nitrous oxide 9 0 Labels and Symbols A removable label Figure 1 Unlock Label located near the keypad provides information on how to unlock the unit Figure 1 Unlock Label If the unit is equipped with...

Page 10: ...rmation Figure 3 Warning Label Figure 4 Identification Label The serial number and date of manufacture of the device are printed on an identification label Figure 4 Identification Label that is locate...

Page 11: ...ding upon your particular circumstances may change these directions Always follow your physician s instructions The ClearLink Controller will track your treatment data However you may want a notebook...

Page 12: ...ter a treatment you may protect any areas that feel sunburned with sunscreen for the next several treatments or until they appear normal Make a note in your notebook You should see your physician at t...

Page 13: ...t is time for the next treatment 11 2 Running a Treatment Note The first time you use the device your dose will automatically appear based on your doctor s prescription After your first treatment the...

Page 14: ...to monitor the amount of light energy being produced by the device The system then automatically adjusts the length of each treatment to account for variations in light output caused by changes in roo...

Page 15: ...ber and close the doors behind you Face either the back or front of the device In order to receive even and effective treatments center yourself within the unit As nearly as possible your torso should...

Page 16: ...e limiting software For each sequence of exposures the number of available treatments is reduced by one A treatment sequence consists of the primary exposure plus up to three repeat exposures if neces...

Page 17: ...ocol between the use of the device on different patients Use a high level disinfectant such as Steris Corporation s Resert XL HLD and follow the manufactures guidelines See also FDA Cleared Sterilants...

Page 18: ...or additional information Note that timely lamp replacement by Daavlin or its authorized agent will avoid this situation 1 First unplug the device then using a hex driver socket remove the screw locat...

Page 19: ...ctrical fast transient burst immunity test following IEC 61000 4 4 2kV 2kV Surge immunity test following IEC 61000 4 5 0 5 kV 1 0 kV 2kV 0 5 kV 1 0 kV 2kV Conducted Immunity test following IEC 61000 4...

Page 20: ...y occur in the vicinity of equipment marked with the following symbol Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 The...

Page 21: ...customer installation improper electrical service lack of proper maintenance and Acts of God This Limited Warranty does not extend to repairs made necessary by use of parts or accessories not recommen...

Page 22: ...declared null and void if non qualified technicians perform any repair or maintenance on the Equipment unless prior written authorization has been obtained from Daavlin Even with Daavlin s authorizat...