NOTE:

 Unit is not to be installed in air handling spaces.

1.  The case brackets provide multiple attachment points for bolts, 

cables, or threaded rod. The following page shows two locations 
for typical threaded rod installations with the external case 
mounting brackets (Figure 1a) and without them (Figure 1b). The 
internal case brackets can be accessed through the hand holes 
(Figure 1c).

2.  The case has a self-trimming flange around the bottom. Ceiling 

tiles or drywall may be placed on top of this flange to provide a 
finished appearance.

3.  After securing the case in the ceiling, check that the case is level 

and plumb. 

4.  Use supplied 1/8” nex key and a 1/4” wrench to remove silver 

shipping brackets attached to slat and screen case.

5.  Install electrical connections that apply to your unit. Refer to the 

electrical diagram on page 4. The electrical connections are 
accessible by removing the two screws on the primary junction 
box cover and the two screws on the secondary low voltage 
cover (Figure 2). You can remove the access door if needed to 
allow for greater access to the electrical wiring. To remove the 
access door; remove the screw from each end of the door while 
holding the door and slide the door off the flanges (Figure 3).

 

NOTE:

 Must be installed in accordance with the requirements of 

the Local Building Codes, the Canadian Electrical Code (CEC), 
CAN/CSA C22.1 and the National Electric Code (NEC), NFPA 70.

Installation

Important Safety Instructions

When using your video equipment, basic safety precautions 
should always be followed, including the following:

1.   Read and understand all instructions before using.

2.  To reduce the risk of electric shock, do not disassemble this 

appliance. Contact an authorized service dealer when repair 
work is required. Incorrect reassembly can cause electric shock 
when the appliance is used subsequently.

3.  The use of an accessory attachment not recommended by the 

manufacturer may cause a risk of fire, electric shock, or injury to 
persons.

4.  Do NOT lift or push up on the camera arm mechanism at any 

time. This may cause improper operation and/or component 
failure or injury to persons.

Pre-Installation

1.  Carefully unpack screen and remove outer wrapping from case.

2.  Make sure to recheck measurements of screen location 

before installation.

Hand Hole

Internal 

Bracket

Figure 1a – Threaded Rod with Internal Bracket

Figure 1b – Threaded Rod with Internal and External Bracket

Figure 1c – Internal Bracket

Hand Hole

Hand Hole

Summary of Contents for Tensioned Conference Electrol

Page 1: ...INSTRUCTION BOOK FOR Tensioned Conference Electrol ...

Page 2: ...he screw from each end of the door while holding the door and slide the door off the flanges Figure 3 NOTE Must be installed in accordance with the requirements of the Local Building Codes the Canadian Electrical Code CEC CAN CSA C22 1 and the National Electric Code NEC NFPA 70 Installation Important Safety Instructions When using your video equipment basic safety precautions should always be foll...

Page 3: ...aced in the up position and when the screen motor stops at its limit switch in the up direction NOTE Excessive continuous operation may cause the motor to overheat If this happens the motor will shut off until it cools to a normal operating temperature 8 Run the screen down enough to open the fabric door Insert the access door on the flanges and reinstall the screws to secure the door Installation...

Page 4: ...terfere with the arm or door mechanisms Leave enough cable to allow for a natural bend at the pivot points Figure 4 Use cable ties if needed to secure the camera cables through the loops Do NOT go around the camera arm tubes with wire ties 3 Connect camera to the cable s and secure the camera to the camera shelf The camera shelf is perforated for easy camera attachment Figure 4 4 Check the camera ...

Page 5: ... supplied RJ 14 cable pre installed White Common Black Hot Green Ground Power Input 120VAC 60Hz NOTE Ground Must be Connected to Building Ground Dry Contacts for Camera Arm Dry Contacts for Camera Arm Bus 5V RJ 45 Receptacle RJ 25 Pin Outs Tab Is Facing Up Standard RJ 25 can be used in place of RJ 14 cable Bus RP Data 12V RQ Clock RQ Data 5V Ground Yellow Green Red Black White Blue RJ 45 Pin Outs ...

Page 6: ...r Motor NOTE Ground Must Be Connected to Building Ground Dry Contacts for Camera Arm Power Input 220VAC 50Hz White Common Red Down Black Up Black Down White Common Red Up Green Yellow Ground RJ 25 Pin Outs Tab Is Facing Up Standard RJ 25 can be used in place of RJ 14 cable Bus RP Data 12V RQ Clock RQ Data 5V Ground Yellow Green Red Black White Blue RJ 45 Pin Outs Tab Is Facing Up 12V Manual 2 Grou...

Page 7: ...tion Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Screen or camera arm will not operate or will not go UP or DOWN and the MOTOR DOES HUM There is power at the junction box Capacitor burned out Replace motor assembly Screen or camera arm will not move upward Motor does not hum Limit switch out ...

Page 8: ...a Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS F...