INSTRUCTION BOOK FOR

 

Tensioned Conference Electrol

Summary of Contents for Tensioned Conference Electrol

Page 1: ...INSTRUCTION BOOK FOR Tensioned Conference Electrol ...

Page 2: ...he screw from each end of the door while holding the door and slide the door off the flanges Figure 3 NOTE Must be installed in accordance with the requirements of the Local Building Codes the Canadian Electrical Code CEC CAN CSA C22 1 and the National Electric Code NEC NFPA 70 Installation Important Safety Instructions When using your video equipment basic safety precautions should always be foll...

Page 3: ...aced in the up position and when the screen motor stops at its limit switch in the up direction NOTE Excessive continuous operation may cause the motor to overheat If this happens the motor will shut off until it cools to a normal operating temperature 8 Run the screen down enough to open the fabric door Insert the access door on the flanges and reinstall the screws to secure the door Installation...

Page 4: ...terfere with the arm or door mechanisms Leave enough cable to allow for a natural bend at the pivot points Figure 4 Use cable ties if needed to secure the camera cables through the loops Do NOT go around the camera arm tubes with wire ties 3 Connect camera to the cable s and secure the camera to the camera shelf The camera shelf is perforated for easy camera attachment Figure 4 4 Check the camera ...

Page 5: ... supplied RJ 14 cable pre installed White Common Black Hot Green Ground Power Input 120VAC 60Hz NOTE Ground Must be Connected to Building Ground Dry Contacts for Camera Arm Dry Contacts for Camera Arm Bus 5V RJ 45 Receptacle RJ 25 Pin Outs Tab Is Facing Up Standard RJ 25 can be used in place of RJ 14 cable Bus RP Data 12V RQ Clock RQ Data 5V Ground Yellow Green Red Black White Blue RJ 45 Pin Outs ...

Page 6: ...r Motor NOTE Ground Must Be Connected to Building Ground Dry Contacts for Camera Arm Power Input 220VAC 50Hz White Common Red Down Black Up Black Down White Common Red Up Green Yellow Ground RJ 25 Pin Outs Tab Is Facing Up Standard RJ 25 can be used in place of RJ 14 cable Bus RP Data 12V RQ Clock RQ Data 5V Ground Yellow Green Red Black White Blue RJ 45 Pin Outs Tab Is Facing Up 12V Manual 2 Grou...

Page 7: ...tion Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Screen or camera arm will not operate or will not go UP or DOWN and the MOTOR DOES HUM There is power at the junction box Capacitor burned out Replace motor assembly Screen or camera arm will not move upward Motor does not hum Limit switch out ...

Page 8: ...a Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS F...