SCREEN ADJUSTMENT FOR 120V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL OR VPI

  1.  Remove the cover plate from the 3-button wall switch and remove the switch from the junction box.
  2.  Locate small 3-position switch on back of wall switch. See Figure 5 for 120V screens or Figure 8 for 220/240V 

screens.

  3.  To adjust the down limit switch, slide the 3-position switch to the down position.  Press and hold the down button 

to run the screen down to the desired stop position.  Release the button to stop the screen.  DO NOT PUSH THE 

STOP BUTTON.

  4.  When the screen is in the desired down position, slide the 3-position switch to the off (center) position.  The down 

limit switch is now set.

  5.  To adjust the up limit switch, slide the 3-position switch to the up position.  Press and hold the up button to run the 

screen up to the desired stop position.  Release the button to stop the screen.  DO NOT PUSH THE STOP BUTTON.

  6.  When the screen is in the desired up position, slide the 3-position switch to the off (center) position.  The up limit 

switch is now set.

  7.  To test limit switch setting, make sure the 3-position switch is in the off (center) position.  Press and release the up 

or down button on the wall switch to operate the screen.

  8.  Replace switch and cover plate on the wall.

NOTE:

 If stop button is pressed, the wall switch will reverse direction.  To correct this, press the stop button again.  This 

will reset the switch.  You will have to re-set both the up and the down limit settings.

IMPORTANT NOTE:

 The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control 

system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is 

accessible.

SCREEN ADJUSTMENT FOR 220V/240V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL

  1.  Locate the wall switch and remove the cover plate from the 3-button wall switch and remove the switch from the 

junction box.

  2.  Locate the two tactile buttons on the back of the switch.  They are square silver with black round buttons. See 

Figure 4 (VPI) or Figure 5 (LVC) for diagram.

  3.  To adjust the down limit switch, press and hold the down tactile button until the LED on back of switch turns solid 

red.  This will put the motor in limit set mode.  Turn the wall switch over and use the down button on front of 

switch.  Press and hold until the desired travel position is reached.  If you travel to far down you can press the up to 

move the screen upward.  If you press and let go of either up or down button the motor will do a small jog in that 

direction for finer adjustment of screen. Once desired position is reached turn switch over press and hold down 

tactile button until the LED on back of switch blinks red twice.  The down limit is now set.

  4.  To adjust the up limit switch, press and hold the up tactile button until the LED on back of switch turns solid green.  

This will put the motor in limit set mode.  Turn the wall switch over and use the up button on front of switch.  Press 

and hold until the desired travel position is reached.  If you travel to far up you can press the down to move the 

screen downward.  If you press and let go of either up or down button the motor will do a small jog in that direction 

for finer adjustment of screen. Once desired position is reached turn switch over press and hold up tactile button 

until the LED on back of switch blinks green twice.  The up limit is now set.

  5.  To test limit switch setting, press and release the up or down button on the wall switch to operate the screen.
  6.  Replace switch and cover plate on the wall.

IMPORTANT NOTE:

 The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control 

system is used.  Therefore, it is advised to wire the switch or provide a 3-conductor connection that is 

accessible.

Summary of Contents for TENSIONED ADVANTAGE ELECTROL

Page 1: ...it Street Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com Instruction Book for tensioned Advantage Electrol The Da Lite Difference ...

Page 2: ...e may overheat 4 To reduce the risk of electric shock do not disassemble this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons SAVE THESE INSTRUCTIONS If...

Page 3: ...CLUDED ATTACHED TO MOUNTING BRACKET SELF TRIMMING FLANGE 6 3 8 7 3 4 FINISHED CEILING 8 6 42 3 8 THREADED ROD NOT SUPPLIED HANGER BRACKET SEE DETAIL A 7 75 DETAIL A 7 95 3 41 ELECTRICAL JUNCTION BOX MOTOR END VARIABLE POSITION MOUNTING BRACKET AUDIENCE SIDE 6 1 16 6 7 16 ...

Page 4: ... wire to extend the low voltage connection from the projector s 5 or 12 volt screen trigger output to the length required to reach the VPI When extending the low voltage connection from the projector s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable GROUND MUST BE CONNECTED TO BUILDING GROUND UP STOP DOWN POWER INPUT 120VAC 60HZ GREEN GROUND ...

Page 5: ...ATA CABLE RJ 45 JACK RJ 45 RECEPTACLE RJ 22 OUTPUT RJ 22 JACK RJ 22 INPUTS RJ 22 JACK LED UP LIMIT TACTILE BUTTON DOWN LIMIT TACTILE BUTTON FRONT OF WALL SWITCH BACK OF WALL SWITCH RJ 22 PIN OUTS TAB IS FACING UP RJ 45 PIN OUTS TAB IS FACING UP Standard RJ 22 can be used in place of RJ 14 Supplied RJ 14 cable BLUE YELLOW GREEN RED BLACK WHITE 12V BUS RP DATA RQ DATA 5V GND RQ CLOCK BUS RP DATA RQ ...

Page 6: ...ustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible CAUTION The projector must be turned off before connecting the trigger wires to the projector Failure to do so may damage the controller 1 Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projector s 5 or 12 volt scree...

Page 7: ...AGE CONTROL MOTOR MOUNT BRACKET MOTOR MOTOR POWER CONNECTOR FIGURE 1 black adjustment knob up white adjustment knob down Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at Da Lite Should it be necessary to adjust for more or less drop of picture proceed in the following manner NOTE Use a screw driver or 5 32 Allen wrench...

Page 8: ...e the wall switch and remove the cover plate from the 3 button wall switch and remove the switch from the junction box 2 Locate the two tactile buttons on the back of the switch They are square silver with black round buttons See Figure 4 VPI or Figure 5 LVC for diagram 3 To adjust the down limit switch press and hold the down tactile button until the LED on back of switch turns solid red This wil...

Page 9: ... installed properly b Fabric has backed up inside case c Fabric is damaged Solution a Verify 115 125V or 220 240V If insufficient voltage rewire incoming electric line b Replace fuse c Reset circuit breaker d Check above Tighten all loose wire connections Correct any improper connections Down Position Check for power across black and white leads Up Position Check for power across red and white lea...

Page 10: ...9 ...

Page 11: ...10 ...

Page 12: ...not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limit...

Reviews: