INSTALLATION

This manual covers installation for both the external SCB-100 and the built-in SCB-100. If you have the external SCB -100,
refer to diagrams 1, 2 and 3 for wire connections. If your screen has the SCB-100 built into the screen case, refer to
diagram 4 for wire connections.

The main power wires (100-240VAC) should always be separated from the low voltage wires. To do this, route the power
and motor wires into the housing using the knockouts on one end of the housing. The wall switch and RS-232 wires
should be routed through the knockouts on the opposite end of the housing.

Do not connect power to the SCB-100 until all other connections are complete.

Wall Switch

The SCB-100 has two manual switch ports. These ports are for dry contact closure only. Port 1 controls motor 1. Port 2
controls motor 2.

1. Install wall switch where desired.

2. Use 3-conductor 20-24 gauge wire to extend the switch wire to the required length.

3. Connect the wall switch to the SCB-100 as shown in diagram 1.

CAUTION: Never apply voltage to the wall switch terminal or the unit will be damaged.

RS-232

The SCB-100 has two RS-232 ports. Port 1 and Port 2 can control either motor 1 or 2.

Both ports are marked with RX, G, TX.

RX-data being received into the SCB-100.
TX-data going out of the SCB-100.
G-ground.

12VDC Out

The SCB-100 supplies voltage to the optional NET-100 network adaptor. The center terminal is not used.

!

1

12VDC OUT FOR OPTIONAL
NET-100 NETWORK
ADAPTOR

Diagram 1

WALL SWITCH 1

RED - UP
BLACK - DOWN
WHITE - COMMON

WALL SWITCH 2

RED - UP
BLACK - DOWN
WHITE - COMMON

RS-232 PORT 1

RX - DATA IN
G - GROUND
TX - DATA OUT

RS-232 PORT 2

RX - DATA IN
G - GROUND
TX - DATA OUT

Summary of Contents for SCB-100

Page 1: ...treet Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 www da lite com e mail info da lite com POWER PRESENTATION PRODUCTS The In Installation and Operating Instructions For SERIAL CONTROL BOARD SCB 100 ...

Page 2: ...e ports are for dry contact closure only Port 1 controls motor 1 Port 2 controls motor 2 1 Install wall switch where desired 2 Use 3 conductor 20 24 gauge wire to extend the switch wire to the required length 3 Connect the wall switch to the SCB 100 as shown in diagram 1 CAUTION Never apply voltage to the wall switch terminal or the unit will be damaged RS 232 The SCB 100 has two RS 232 ports Port...

Page 3: ...th Power Source 1 Connect power wires to the SCB 100 as shown in diagram 3 2 Connect the building ground wire to the ground lug on the metal housing Diagram 2 SCREEN 2 OR PROJECTOR LIFT SCREEN 1 WHITE COMMON BLACK DOWN RED UP WHITE COMMON BLACK DOWN RED UP Diagram 3 SOURCE INPUT 100 240 VAC GREEN GROUND BLACK HOT WHITE COMMON 2 INSTALLATION SOURCE INPUT 100 120 VAC SCREEN 2 OR PROJECTOR LIFT SCREE...

Page 4: ...connections RS 232 Ports The SCB 100 has two RS 232 ports Both ports have three wire connections RX Data being received into the SCB 100 TX Data going out of the SCB 100 G Ground Wall Switch The wall switch terminal is a dry contact closure Do not apply voltage to this terminal or the control will be damaged 1 Install the wall switch where desired 2 Use 3 conductor 20 24 gauge wire to extend the s...

Reviews: