background image

4

Screen Adjustment For Screens Without A Built-In Low Voltage Control

Screen travel is stopped automatically in the down and up positions by the limit switches that are preset at the factory.  

No further adjustment is necessary.

If you need to make minor stop position adjustments see the appropriate step below.

Setting The Down Limit Position

NOTE: 

One turn of the limit screw equals approximately 2" of 

screen travel.

To Reduce Screen Drop:

 

Turn the down limit switch screw clockwise to decrease the 
amount of screen drop. Run the screen down to test the stop 
position. If the screen drops too far, raise the screen about  
one foot and adjust the limit switch again. Repeat until the  
desired position is set.

To Increase Screen Drop:

 

Turn the down limit switch screw counterclockwise to increase  
the amount of screen drop. Run the screen down to test the stop 
position. If the screen does not drop enough, raise the screen 
about one foot and adjust the limit switch again. Repeat until the 
desired position is set. Do not adjust for more drop than what was 
ordered. At least 1-1/2 wraps of fabric must remain on the roller.

Setting The Up Limit Position

 

CAUTION: Do not allow the slat bar to wrap over the top  
of the roller when the screen is rolling into the case.  
The screen could be damaged.

Screen Travels Into Case Too Far:

 

Turn the up limit switch screw clockwise to decrease the amount 
of travel. Run the screen up to test the stop position. If the screen 
does not stop properly, lower the screen about one foot and turn 
the limit switch again. Repeat until the desired position is set.

Screen Does Not Travel Far Enough Into Case:

 

Turn the up limit switch screw counterclockwise to increase the 
amount of up travel. Run the screen up to test the stop position. If 
more travel is desired, lower the screen about one foot and adjust 
the limit switch again. Repeat until the desired position is set.

Up Limit Switch Access 
Through Case Opening

Down Limit 

Switch Access 

Hole

Figure 3

Summary of Contents for Large Cosmopolitan Electrol

Page 1: ...INSTRUCTION BOOK FOR Large Cosmopolitan Electrol ...

Page 2: ... bracket using the supplied 5 16 x 3 4 bolts washers and nuts 3 Position the ceiling bracket assembly on the ceiling and attach with 5 16 bolts not supplied The bolts should be long enough to pass through the drywall or ceiling tile and penetrate at least 1 1 2 into the reinforcement in the ceiling 4 Mount the screen on the wall bracket as shown in figure 2 Be sure the case is fully seated on the ...

Page 3: ...optional low voltage control must be used 240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH Da Lite offers two styles of 240 volt wall switches for standard operation Please see wiring diagram in wall switch boxes included with screen This Switch Can Not be used with LVC 120V Wiring Diagram For Standard Wall Switch SPDT Switch with Center Off AC Common AC Hot 120VAC 60HZ 1 AMP Black Yellow Black Re...

Page 4: ...not drop enough raise the screen about one foot and adjust the limit switch again Repeat until the desired position is set Do not adjust for more drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller Setting The Up Limit Position CAUTION Do not allow the slat bar to wrap over the top of the roller when the screen is rolling into the case The screen could be damaged Sc...

Page 5: ...reen Yellow Red Black Orange Purple Brown 120V Wiring Diagram 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Theref...

Page 6: ...t Back UP DN GND 5V 3 Position Switch RJ9 UP 5V COM DN IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible Connect Supplied RJ9 Cable to Splitter and Switch or use 4 Cable Conductor to Connect to Screw Terminals ILT RJ 9 Pin Outs...

Page 7: ... the back of the switch They are square silver with black round buttons See Figure 4 VPI or Figure 5 LVC for diagram 3 To adjust the down limit switch press and hold the down tactile button until the LED on back of switch turns solid red This will put the motor in limit set mode Turn the wall switch over and use the down button on front of switch Press and hold until the desired travel position is...

Page 8: ...ion in downward direction Lost roller wrap See instructions below Down limit switch out of adjustment See installation instructions Incorrect stopping position in upward direction Lost roller wrap See instructions below Up limit switch out of adjustment Adjust up limit switch Call for information Noise NOTE Screen will operate with a low pitched hum Gear noise Replace motor assembly Coasting Defec...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...HE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have o...

Reviews: