9
1. To connect power to unit locate junction box cover on
bottom frame assembly. There will be two black screws
holding the wiring box cover on as shown in Figure 13.
2. Install electrical connections. Make sure to review the
wiring diagram for proper hook up as shown in Figure 14.
NOTE:
Must be installed in accordance with the requirements
of the Local Building Codes, the Canadian Electrical Code
(CEC), CAN/CSA C22.1 and the National Electric Code (NEC),
NFPA 70. An appropriate disconnect device shall be provided
as part of the building installation.
NOTE:
Be sure the unit is wired to a branch circuit rated no
less than 20A.
Multi Format Imager Wiring Diagram
Left Motor
Right Motor
Quick Connect
Motor Plug
RJ-45
Coupler
Three Conductor
Power Wire
Quick Connect
Motor Plug
White (Common)
Black (Hot)
8P8C
RJ-45 Cable
RJ-45
6P6C
RJ-22 Cable
From Qaux
To Qeye
Remove Two
Screws Holding
Junction Box Cover
Green
(Ground)
Input 120V / 60Hz
RJ-45
Coupler
Figure 14
Figure 13
+12V
Manual 2
Ground
Manual 1
RQ Clock
Bus (RP Data)
RQ Data
+5V
Blue
Green
Yellow
Red
Black
Orange
Purple
Brown