background image

7

TROUBLESHOOTING

SYMPTOM

If screen is not responding properly and
SCB100 or SCB200 controls are used,
contact the factory for troubleshooting
assistance.

1.

Screen will not operate or will not go

“down”

.

Motor does

not 

hum.

Motor

hums.

2.

Screen will not move

upward.

Motor does 

not

hum.

Motor 

hums.

CAUSE

(a)

Incorrect line voltage.

(b) Blown facility fuse.

(c)

Tripped facility circuit breaker.

(d)

No power

to operating switch or

junction box.

Power at junction box.

(e) Thermal overload tripped.

(f)

Broken wire in the 

“down”

position.

(g) Defective motor, limit switch or 

capacitor.

(h) Capacitor burned out.

(a)

Incorrect line voltage.

(b) Blown facility fuse.

(c)

Tripped facility circuit breaker.

(d)

No power

to operating switch or 

junction box.

(e) Open door limit switch.

Power at junction box

(f)

Thermal overload tripped.

(g) Broken wire in the 

“up” 

position.

(h) Defective motor, limit switch or 

capacitor.

(i)

Capacitor burned out.

SOLUTION

(a)

Verify 115-125V (or 220-240V). If
insufficient voltage, rewire incoming
electric line.

(b) Replace facility fuse.

(c)

Reset facility circuit breaker.

(d) Check above. Tighten all loose wire

connections. Recheck wiring. See
installation instructions.

“Down” Position

Check for power across black and white

leads.

(e) Let motor cool down for 15 minutes.

Try again.

(f)

Check for continuity.

(g) Replace motor assembly.

NOTE: Motor is a sealed assembly.

(h) Replace motor assembly.

(a)

Verify 115-125V (or 220-240V). If
insufficient voltage, rewire incoming
electric line.

(b) Replace facility fuse.

(c)

Reset facility circuit breaker.

(d) Check above. Tighten all loose wire

connections. See above.

“Up” Position

Check for power across red and
white leads.

(e) Replace switch.

(f)

Let motor cool down for 15 minutes.
Try again.

(g) Check for continuity.

(h) Replace motor assembly.

NOTE: Motor is a sealed assembly.

(i)

Replace motor assembly.

Summary of Contents for ADV DLX 120D

Page 1: ...treet Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com POWER PRESENTATION PRODUCTS The In Instruction Book for ADVANTAGE DELUXE ELECTROL ...

Page 2: ...rounding the junction box Remove two screws for access 1 Carefully unpack screen and remove outer wrapping from case 2 Make sure to recheck measurements of screen location before installation IMPORTANT SAFETY INSTRUCTIONS When using your video equipment basic safety precautions should always be followed including the following 1 Read and understand all instructions before using 2 Position the cord...

Page 3: ... up direction NOTE Excessive continuous operation may cause the motor to overheat If this happens the motor will shut off until it cools to a normal operating temperature 8 Run the screen down enough to open the fabric door Close the access door and reinstall the screws to secure the door SCREEN AND ROLLER ASSEMBLY INSTALLATION SCREEN ADJUSTMENT The screen controller standard control not SCB100 or...

Page 4: ... WH HIIT TE E COMMON BLACK HOT GREEN GROUND POWER INPUT 120VAC 60HZ DOOR MOTOR DOWN STOP UP SCREEN MOTOR EYE AUX BLUE COMMON BROWN HOT GREEN YELLOW GROUND DOOR MOTOR DOWN STOP UP NOTE Electrical connections on left end of case NOTE Electrical connections on left end of case AUX EYE OPTIONAL RF OR IR REMOTE CONNECTOR NOT USED W W H H I I T T E E COMMON RED UP BLACK DOWN NOT USED NOT USED W WH HI IT...

Page 5: ...E ELECTROL INSTRUCTIONS SCB 100 CONTROL POWER INPUT AND CONTROL BOARD ARE LOCATED ON RIGHT SIDE OF SCREEN HOUSING 220 240V WIRING DIAGRAM 120V WIRING DIAGRAM NOTE Electrical connections on right side of case NOTE Electrical connections on right side of case BLACK HOT GREEN GROUND W WH HIIT TE E COMMON POWER INPUT 120VAC 60HZ DOWN STOP UP NOT USED BACK OF FRONT OF WALL SWITCH WALL SWITCH SCREEN MOT...

Page 6: ...LECTROL INSTRUCTIONS SCB 200 CONTROL POWER INPUT AND CONTROL BOARD ARE LOCATED ON RIGHT SIDE OF SCREEN HOUSING 220 240V WIRING DIAGRAM 120V WIRING DIAGRAM NOTE Electrical connections on right side of case NOTE Electrical connections on right side of case BLACK HOT GREEN GROUND W WH HIIT TE E COMMON POWER INPUT 120VAC 60HZ NOT USED ENCODER 5V A B GND SCREEN MOTOR DOOR MOTOR SCREEN AND DOOR MOTOR MI...

Page 7: ...CKET FINISHED CEILING SELF TRIMMING FLANGE 7 1 4 8 3 4 CASE LENGTH VARIABLE POSITION MOUNTING BRACKETS 7 1 4 6 1 8 MOTOR END 6 1 8 ELECTRICAL JUNCTION BOX SEE DETAIL A SUGGESTED 3 8 THREADED ROD NOT INCLUDED 4 59 7 21 8 75 DETAIL A 8 74 HANGER BRACKET 7 1 4 FLAT BAR MOUNTING METHOD FORMED BRACKET MOUNTING METHOD ...

Page 8: ... g Broken wire in the up position h Defective motor limit switch or capacitor i Capacitor burned out SOLUTION a Verify 115 125V or 220 240V If insufficient voltage rewire incoming electric line b Replace facility fuse c Reset facility circuit breaker d Check above Tighten all loose wire connections Recheck wiring See installation instructions Down Position Check for power across black and white le...

Page 9: ...nit not calibrated a Down limit switch out of adjustment a Buzzing noise b Gear noise a Defective brake a Pin end slipped out of nylon bearing a Screen not installed properly b Fabric is damaged a Screen up limit out of adjustment a Loose wire SOLUTION a Check installation to free door Clear any foreign substance i e paint or plaster from hinge b See above a Replace switch b Replace screen motor c...

Reviews: