Unit assembly
C. Vertical solar system
The cold water inlet line, the hot water outlet line, the solar system inlet line, the solar system return line and the connections of the
plumbing recirculation line must be equivalent to those described in the instructions for the single worm water tank.
D. Accumulator Tank
When installing the accumulator tank, make sure the base is strong enough to support its weight. The base must be mounted on a
suitable floor.
The accumulator tank must be connected to the flat plate exchanger according to the instructions of the table provided in the direc-
tory (image 3).
Electrical installation connection
1-
The effective voltage of the optional thermostat heating element is 220 volts AC. (On special occasions it
may be 380 volts AC).
2-
If the mains is 110 volts, install a 110/220 volt and 3,000 watt transformer in the middle.
3-
If the amperage of the place where the water tank is to be used is under 16 amps, change the fuse.
4-
The heating element network must be connected in at least three sections of transversal wire of 5 mm.
5-
The electrical installation of the device must be carried out by a qualified electrician.
6-
Do not forget to connect the apparatus to ground. Our company waives all liability for problems occurring
by not connecting the equipment to ground.
Use of INTERSOL 1 with AQUATERMIC
If the INTERSOL 1 tanks is used for the AQUATERMIC, a sheath (not supplied) must be inserted in the socket marked “circula-
tion tank”, where the bulb of the TRB danfoss KP77 thermostat must be inserted.
OPERATION